Design, Implementation, and Performance Evaluation of a Fiber Bragg Gratings(FBG) based Smart Insole to Measure Plantar Pressure and Temperature
Authors:
Sakib Mahmud,
Amith Khandakar,
Muhammad E. H. Chowdhury,
Mohammed AbdulMoniem,
Mamun Bin Ibne Reaz,
Zaid Bin Mahbub,
Kishor Kumar Sadasivuni,
M Murugappan,
Mohammed Alhatou
Abstract:
Various foot complications can be easily avoided by continuous monitoring of foot plantar temperature and pressure. In this work, the design, characterization, and implementation of a Fiber Bragg Gratings (FBG) based smart insole capable of simultaneously measuring plantar pressure and temperature has been reported. The instrumented insole was tested and verified during static and gait exercises.…
▽ More
Various foot complications can be easily avoided by continuous monitoring of foot plantar temperature and pressure. In this work, the design, characterization, and implementation of a Fiber Bragg Gratings (FBG) based smart insole capable of simultaneously measuring plantar pressure and temperature has been reported. The instrumented insole was tested and verified during static and gait exercises. The paper also provides a comparison of the developed optoelectronic-based solution with a commercially available and widely used plantar pressure measurement and analysis system and a lab-made, electronic sensor-based smart insole that can measure both plantar temperature and pressure. It was shown that even though the commercially available expensive system is very robust and highly precise due to many sensing units on the insole, the developed insole with a smaller number of sensors can provide both plantar temperature and pressure with reasonable precision while displaying both foot pressure and temperature maps, and gait cycle plots in real-time. The FBG-based solution is comfortable and safer than the other systems being compared. Thus, confirming the effectiveness of the proposed solution as an addition to the research area for detecting foot complications non-invasively using foot insoles.
△ Less
Submitted 25 August, 2022;
originally announced August 2022.
-
Design and Implementation of a Complete Wearable Smart Insole Solution to Measure Plantar Pressure and Temperature
Authors:
Amith Khandakar,
Sakib Mahmud,
Muhammad E. H. Chowdhury,
Mamun Bin Ibne Reaz,
Serkan Kiranyaz,
Zaid Bin Mahbub,
Sawal Hamid Md Ali,
Ahmad Ashrif A Bakar,
Mohammed Alhatou,
Mohammed AbdulMoniem
Abstract:
A complete smart insole solution that continuously monitors the foot plantar pressure and temperature can detect foot complications early and that too from the convenience of the user home. Widespread health complications such as Diabetic Mellitus need continuous foot complication monitoring to avoid severe complications. With that motivation, this paper provides a detailed design of a wearable in…
▽ More
A complete smart insole solution that continuously monitors the foot plantar pressure and temperature can detect foot complications early and that too from the convenience of the user home. Widespread health complications such as Diabetic Mellitus need continuous foot complication monitoring to avoid severe complications. With that motivation, this paper provides a detailed design of a wearable insole using popular off-the-shelf sensors to monitor foot plantar pressure and temperature. The design provides details of which temperature and pressure to be used, circuit configuration for characterizing the sensors, and the considerations for developing a compact Printed Circuit board design using appropriate microcontrollers and communication protocol. The system also provides details of how the foot pressure and temperature data from the subjects using the sensors can be transferred wirelessly using a low-power consuming communication protocol to a central device where the data will be recorded. The investigation can help in developing a low-cost, feasible and portable foot monitoring system for patients by facilitating real-time, home monitoring of foot condition using Gait Cycle or Foot Pressure patterns and temperature heterogeneity between two feet. The proposed system will work in real-time.
△ Less
Submitted 15 June, 2022;
originally announced June 2022.
-
Motion Artifacts Correction from Single-Channel EEG and fNIRS Signals using Novel Wavelet Packet Decomposition in Combination with Canonical Correlation Analysis
Authors:
Md Shafayet Hossain,
Muhammad E. H. Chowdhury,
Mamun Bin Ibne Reaz,
Sawal H. M. Ali,
Ahmad Ashrif A. Bakar,
Serkan Kiranyaz,
Amith Khandakar,
Mohammed Alhatou,
Rumana Habib,
Muhammad Maqsud Hossain
Abstract:
The electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals, highly non-stationary in nature, greatly suffers from motion artifacts while recorded using wearable sensors. This paper proposes two robust methods: i) Wavelet packet decomposition (WPD), and ii) WPD in combination with canonical correlation analysis (WPD-CCA), for motion artifact correction from single-chan…
▽ More
The electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals, highly non-stationary in nature, greatly suffers from motion artifacts while recorded using wearable sensors. This paper proposes two robust methods: i) Wavelet packet decomposition (WPD), and ii) WPD in combination with canonical correlation analysis (WPD-CCA), for motion artifact correction from single-channel EEG and fNIRS signals. The efficacy of these proposed techniques is tested using a benchmark dataset and the performance of the proposed methods is measured using two well-established performance matrices: i) Difference in the signal to noise ratio (ΔSNR) and ii) Percentage reduction in motion artifacts (η). The proposed WPD-based single-stage motion artifacts correction technique produces the highest average ΔSNR (29.44 dB) when db2 wavelet packet is incorporated whereas the greatest average η (53.48%) is obtained using db1 wavelet packet for all the available 23 EEG recordings. Our proposed two-stage motion artifacts correction technique i.e. the WPD-CCA method utilizing db1 wavelet packet has shown the best denoising performance producing an average ΔSNR and η values of 30.76 dB and 59.51%, respectively for all the EEG recordings. On the other hand, the two-stage motion artifacts removal technique i.e. WPD-CCA has produced the best average ΔSNR (16.55 dB, utilizing db1 wavelet packet) and largest average η (41.40%, using fk8 wavelet packet). The highest average ΔSNR and η using single-stage artifacts removal techniques (WPD) are found as 16.11 dB and 26.40%, respectively for all the fNIRS signals using fk4 wavelet packet. In both EEG and fNIRS modalities, the percentage reduction in motion artifacts increases by 11.28% and 56.82%, respectively when two-stage WPD-CCA techniques are employed.
△ Less
Submitted 9 April, 2022;
originally announced April 2022.
-
A machine learning-based severity prediction tool for diabetic sensorimotor polyneuropathy using Michigan neuropathy screening instrumentations
Authors:
Fahmida Haque,
Mamun B. I. Reaz,
Muhammad E. H. Chowdhury,
Rayaz Malik,
Mohammed Alhatou,
Syoji Kobashi,
Iffat Ara,
Sawal H. M. Ali,
Ahmad A. A Bakar,
Geetika Srivastava
Abstract:
Background: Diabetic Sensorimotor polyneuropathy (DSPN) is a major long-term complication in diabetic patients associated with painful neuropathy, foot ulceration and amputation. The Michigan neuropathy screening instrument (MNSI) is one of the most common screening techniques for DSPN, however, it does not provide any direct severity grading system. Method: For designing and modelling the DSPN se…
▽ More
Background: Diabetic Sensorimotor polyneuropathy (DSPN) is a major long-term complication in diabetic patients associated with painful neuropathy, foot ulceration and amputation. The Michigan neuropathy screening instrument (MNSI) is one of the most common screening techniques for DSPN, however, it does not provide any direct severity grading system. Method: For designing and modelling the DSPN severity grading systems for MNSI, 19 years of data from Epidemiology of Diabetes Interventions and Complications (EDIC) clinical trials were used. MNSI variables and patient outcomes were investigated using machine learning tools to identify the features having higher association in DSPN identification. A multivariable logistic regression-based nomogram was generated and validated for DSPN severity grading. Results: The top-7 ranked features from MNSI: 10-gm filament, Vibration perception (R), Vibration perception (L), previous diabetic neuropathy, the appearance of deformities, appearance of callus and appearance of fissure were identified as key features for identifying DSPN using the extra tree model. The area under the curve (AUC) of the nomogram for the internal and external datasets were 0.9421 and 0.946, respectively. From the developed nomogram, the probability of having DSPN was predicted and a DSPN severity scoring system for MNSI was developed from the probability score. The model performance was validated on an independent dataset. Patients were stratified into four severity levels: absent, mild, moderate, and severe using a cut-off value of 10.5, 12.7 and 15 for a DSPN probability less than 50%, 75% to 90%, and above 90%, respectively. Conclusions: This study provides a simple, easy-to-use and reliable algorithm for defining the prognosis and management of patients with DSPN.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.