-
T-RAX: Transversely Resonant Axion eXperiment
Authors:
Chang Lee,
Olaf Reimann
Abstract:
We propose to use an elongated rectangular waveguide near its cutoff frequency for axionic dark matter searches. The detector's large surface area allows for significant signal power, while its narrow transverse dimension and tapered-waveguide coupling suppress parasitic modes. The proposed system can fit inside a solenoid magnet and is sensitive to the QCD-axion in the axion mass $40-400\,μ$eV. W…
▽ More
We propose to use an elongated rectangular waveguide near its cutoff frequency for axionic dark matter searches. The detector's large surface area allows for significant signal power, while its narrow transverse dimension and tapered-waveguide coupling suppress parasitic modes. The proposed system can fit inside a solenoid magnet and is sensitive to the QCD-axion in the axion mass $40-400\,μ$eV. We describe the theoretical principles of the new design, present simulation results, and discuss the implementation.
△ Less
Submitted 22 June, 2022; v1 submitted 29 March, 2022;
originally announced March 2022.
-
A new experimental approach to probe QCD axion dark matter in the mass range above 40$μ$eV
Authors:
The MADMAX Collaboration,
P. Brun,
A. Caldwell,
L. Chevalier,
G. Dvali,
P. Freire,
E. Garutti,
S. Heyminck,
J. Jochum,
S. Knirck,
M. Kramer,
C. Krieger,
T. Lasserre,
C. Lee,
X. Li,
A. Lindner,
B. Majorovits,
S. Martens,
M. Matysek,
A. Millar,
G. Raffelt,
J. Redondo,
O. Reimann,
A. Ringwald,
K. Saikawa
, et al. (6 additional authors not shown)
Abstract:
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The…
▽ More
The axion emerges in extensions of the Standard Model that explain the absence of CP violation in the strong interactions. Simultaneously, it can provide naturally the cold dark matter in our universe. Several searches for axions and axion-like particles (ALPs) have constrained the corresponding parameter space over the last decades but no unambiguous hints of their existence have been found. The axion mass range below 1 meV remains highly attractive and a well motivated region for dark matter axions. In this White Paper we present a description of a new experiment based on the concept of a dielectric haloscope for the direct search of dark matter axions in the mass range of 40 to 400 $μ$eV. This MAgnetized Disk and Mirror Axion eXperiment (MADMAX) will consist of several parallel dielectric disks, which are placed in a strong magnetic field and with adjustable separations. This setting is expected to allow for an observable emission of axion induced electromagnetic waves at a frequency between 10 to 100 GHz corresponding to the axion mass.
△ Less
Submitted 28 October, 2020; v1 submitted 22 January, 2019;
originally announced January 2019.
-
Dielectric Haloscopes: A New Way to Detect Axion Dark Matter
Authors:
The MADMAX Working Group,
Allen Caldwell,
Gia Dvali,
Bela Majorovits,
Alexander Millar,
Georg Raffelt,
Javier Redondo,
Olaf Reimann,
Frank Simon,
Frank Steffen
Abstract:
We propose a new strategy to search for dark matter axions in the mass range of 40--400 $μ$eV by introducing dielectric haloscopes, which consist of dielectric disks placed in a magnetic field. The changing dielectric media cause discontinuities in the axion-induced electric field, leading to the generation of propagating electromagnetic waves to satisfy the continuity requirements at the interfac…
▽ More
We propose a new strategy to search for dark matter axions in the mass range of 40--400 $μ$eV by introducing dielectric haloscopes, which consist of dielectric disks placed in a magnetic field. The changing dielectric media cause discontinuities in the axion-induced electric field, leading to the generation of propagating electromagnetic waves to satisfy the continuity requirements at the interfaces. Large-area disks with adjustable distances boost the microwave signal (10--100 GHz) to an observable level and allow one to scan over a broad axion mass range. A sensitivity to QCD axion models is conceivable with 80 disks of 1 m$^2$ area contained in a $10$ Tesla field.
△ Less
Submitted 3 March, 2017; v1 submitted 17 November, 2016;
originally announced November 2016.
-
Contributions of the Cherenkov Telescope Array (CTA) to the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
C. Adams,
G. Agnetta,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
J. Alfaro,
R. Alfaro,
A. J. Allafort,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
M. Anduze,
E. O. Angüner
, et al. (1387 additional authors not shown)
Abstract:
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
CTA Contributions to the 34th International Cosmic Ray Conference (ICRC2015)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio
, et al. (1290 additional authors not shown)
Abstract:
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
△ Less
Submitted 11 September, 2015; v1 submitted 24 August, 2015;
originally announced August 2015.
-
The Cherenkov Telescope Array Large Size Telescope
Authors:
G. Ambrosi,
Y. Awane,
H. Baba,
A. Bamba,
M. Barceló,
U. Barres de Almeida,
J. A. Barrio,
O. Blanch Bigas,
J. Boix,
L. Brunetti,
E. Carmona,
E. Chabanne,
M. Chikawa,
P. Colin,
J. L. Conteras,
J. Cortina,
F. Dazzi,
A. Deangelis,
G. Deleglise,
C. Delgado,
C. Díaz,
F. Dubois,
A. Fiasson,
D. Fink,
N. Fouque
, et al. (107 additional authors not shown)
Abstract:
The two arrays of the Very High Energy gamma-ray observatory Cherenkov Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA to achieve a low-energy threshold of 20 GeV, which is critical for important studies in astrophysics, astroparticle physics and cosmology. This work presents the key speci…
▽ More
The two arrays of the Very High Energy gamma-ray observatory Cherenkov Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA to achieve a low-energy threshold of 20 GeV, which is critical for important studies in astrophysics, astroparticle physics and cosmology. This work presents the key specifications and performance of the current LST design in the light of the CTA scientific objectives.
△ Less
Submitted 17 July, 2013;
originally announced July 2013.
-
CTA contributions to the 33rd International Cosmic Ray Conference (ICRC2013)
Authors:
The CTA Consortium,
:,
O. Abril,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
M. Ajello,
A. Akhperjanian,
M. Alcubierre,
J. Aleksic,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
E. Amato,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
E. O. Angüner,
L. A. Antonelli,
V. Antonuccio
, et al. (1082 additional authors not shown)
Abstract:
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
△ Less
Submitted 29 July, 2013; v1 submitted 8 July, 2013;
originally announced July 2013.
-
Development of HPD Clusters for MAGIC-II
Authors:
R. Orito,
E. Bernardini,
D. Bose,
A. Dettlaff,
D. Fink,
V. Fonseca,
M. Hayashida,
J. Hose,
E. Lorenz,
K. Mannheim,
R. Mirzoyan,
O. Reimann,
T. Y. Saito,
T. Schweizer,
M. Shayduk,
M. Teshima
Abstract:
MAGIC-II is the second imaging atmospheric Cherenkov telescope of the MAGIC observatory, which has recently been inaugurated on Canary island of La Palma. We are currently developing a new camera based on clusters of hybrid photon detectors (HPD) for the upgrade of MAGIC-II. The photon detectors feature a GaAsP photocathode and an avalanche diode as electron bombarded anodes with internal gain,…
▽ More
MAGIC-II is the second imaging atmospheric Cherenkov telescope of the MAGIC observatory, which has recently been inaugurated on Canary island of La Palma. We are currently developing a new camera based on clusters of hybrid photon detectors (HPD) for the upgrade of MAGIC-II. The photon detectors feature a GaAsP photocathode and an avalanche diode as electron bombarded anodes with internal gain, and were supplied by Hamamatsu Photonics K.K. (R9792U-40). The HPD camera with high quantum efficiency will increase the MAGIC-II sensitivity and lower the energy threshold. The basic performance of the HPDs has been measured and a prototype of an HPD cluster has been developed to be mounted on MAGIC-II. Here we report on the status of the HPD cluster and the project of eventually using HPD clusters in the central area of the MAGIC-II camera.
△ Less
Submitted 5 July, 2009;
originally announced July 2009.
-
Performance of the Camera of the MAGIC II Telescope
Authors:
D. Borla Tridon,
F. Goebel,
D. Fink,
W. Haberer,
J. Hose,
C. C. Hsu,
T. Jogler,
R. Mirzoyan,
R. Orito,
O. Reimann,
P. Sawallisch,
J. Schlammer,
T. Schweizer,
B. Steinke,
M. Teshima
Abstract:
MAGIC comprises two 17m diameter IACTs to be operated in stereo mode. Currently we are commissioning the second telescope, MAGIC II. The camera of the second telescope has been equipped with 1039 pixels of 0.1-degree diameter. Always seven pixels are grouped in a hexagonal configuration to form a cluster. This modular design allows easier control and maintenance of the camera. The pixel sensors…
▽ More
MAGIC comprises two 17m diameter IACTs to be operated in stereo mode. Currently we are commissioning the second telescope, MAGIC II. The camera of the second telescope has been equipped with 1039 pixels of 0.1-degree diameter. Always seven pixels are grouped in a hexagonal configuration to form a cluster. This modular design allows easier control and maintenance of the camera. The pixel sensors are high quantum efficiency photomultiplier tubes (PMTs) from Hamamatsu (superbialkali type, QE ~ 32% at the peak wavelength) that we operate at rather low gain of 30 k. This allows us to also perform extended observations under moderate moonlight. The system of two MAGIC telescopes will at least double the sensitivity compared to MAGIC I and also will allow us to lower the energy threshold.Here we will report the performances of the Camera of the second MAGIC telescope.
△ Less
Submitted 30 June, 2009;
originally announced June 2009.
-
The Camera of the MAGIC-II Telescope
Authors:
C. C. Hsu,
A. Dettlaff,
D. Fink,
F. Goebel,
W. Haberer,
J. Hose,
R. Maier,
R. Mirzoyan,
W. Pimpl,
O. Reimann,
A. Rudert,
P. Sawallisch,
J. Schlammer,
S. Schmidl,
A. Stipp,
M. Teshima
Abstract:
The MAGIC 17m diameter Cherenkov telescope will be upgraded with a second telescope within the year 2007. The camera of MAGIC-II will include several new features compared to the MAGIC-I camera. Photomultipliers with the highest available photon collection efficiency have been selected. A modular design allows easier access and flexibility to test new photodetector technologies. The camera will…
▽ More
The MAGIC 17m diameter Cherenkov telescope will be upgraded with a second telescope within the year 2007. The camera of MAGIC-II will include several new features compared to the MAGIC-I camera. Photomultipliers with the highest available photon collection efficiency have been selected. A modular design allows easier access and flexibility to test new photodetector technologies. The camera will be uniformly equipped with 0.1 degree diamter pixels, which allows the use of an increased trigger area. Finally, the overall signal chain features a large bandwidth to retain the shape of the very fast Cherenkov signals.
△ Less
Submitted 16 September, 2007;
originally announced September 2007.