A universal bioluminescence tomography system for pre-clinical image-guided radiotherapy research
Authors:
Zhishen Tong,
Zijian Deng,
Xiangkun Xu,
Ciara Newman,
Xun Jia,
Yuncheng Zhong,
Merle Reinhart,
Paul Tsouchlos,
Tim Devling,
Hamid Dehghani,
Iulian Iordachita,
Debabrata Saha,
John W. Wong,
Ken Kang-Hsin Wang
Abstract:
CBCT-guided small animal irradiators encounter challenges in localizing soft-tissue targets due to low imaging contrast. Bioluminescence tomography (BLT) offers a promising solution, but they have largely remained in laboratorial development, limiting accessibility for researchers. In this work, we develop a universal, commercial-graded BLT-guided system (MuriGlo) designed to seamlessly integrate…
▽ More
CBCT-guided small animal irradiators encounter challenges in localizing soft-tissue targets due to low imaging contrast. Bioluminescence tomography (BLT) offers a promising solution, but they have largely remained in laboratorial development, limiting accessibility for researchers. In this work, we develop a universal, commercial-graded BLT-guided system (MuriGlo) designed to seamlessly integrate with commercial irradiators and empower researchers for translational studies. We demonstrate its capabilities in supporting in vitro and in vivo studies. The MuriGlo comprises detachable mouse bed, thermostatic control, mirrors, filters, and CCD, enabling multi-projection and multi-spectral imaging. We evaluate that the thermostatic control effectively sustains animal temperature at 37°C throughout imaging, and quantify that the system can detect as few as 61 GL261-AkaLuc cells in vitro. To illustrate how the MuriGlo can be utilized for in vivo image-guided research, we present 3 strategies, BLT-guided 5-arc, 2-field box, and BLI-guided single-beam, ranging from complicated high-conformal to simplest high-throughput plans. The high conformal BLT-guided 5-arc plan fully covers the gross tumor volume (GTV) at prescribed dose with minimal normal tissue exposure (3.9%), while the simplified, high-throughput BLT-guided 2-field box achieves 100% GTV coverage but results in higher normal tissue exposure (13.1%). Moreover, we demonstrate that the localization accuracy of MuriGlo for both widely-used SARRP and SmART irradiators is within1 mm, and the tumor coverage reaches over 97% with 0.75mm margin. The universal BLT-guided system offers seamless integration with commercial irradiators, achieving comparable localization accuracy, expected to supporting high-precision radiation research.
△ Less
Submitted 27 June, 2024; v1 submitted 18 June, 2024;
originally announced June 2024.
Quantitative Bioluminescence Tomography-guided System for Conformal Irradiation In Vivo
Authors:
Xiangkun Xu,
Zijian Deng,
Hamid Dehghani,
Iulian Iordachita,
Michael Lim,
John W. Wong,
Ken Kang-Hsin Wang
Abstract:
Although cone-beam CT (CBCT) has been used to guide irradiation for pre-clinical radiotherapy(RT) research, it is limited to localize soft tissue target especially in a low imaging contrast environment. Knowledge of target shape is a fundamental need for RT. Without such information to guide radiation, normal tissue can be irradiated unnecessarily, leading to experimental uncertainties. Recognitio…
▽ More
Although cone-beam CT (CBCT) has been used to guide irradiation for pre-clinical radiotherapy(RT) research, it is limited to localize soft tissue target especially in a low imaging contrast environment. Knowledge of target shape is a fundamental need for RT. Without such information to guide radiation, normal tissue can be irradiated unnecessarily, leading to experimental uncertainties. Recognition of this need led us to develop quantitative bioluminescence tomography (QBLT), which provides strong imaging contrast to localize optical targets. We demonstrated its capability of guiding conformal RT using an orthotopic bioluminescent glioblastoma (GBM) model. With multi-projection and multi-spectral bioluminescence imaging and a novel spectral derivative method, our QBLT system is able to reconstruct GBM with localization accuracy <1mm. An optimal threshold was determined to delineate QBLT reconstructed gross target volume (GTV_{QBLT}), which provides the best overlap between the GTV_{QBLT} and CBCT contrast labeled GBM (GTV), used as the ground truth for the GBM volume. To account for the uncertainty of QBLT in target localization and volume delineation, we also innovated a margin design; a 0.5mm margin was determined and added to GTV_{QBLT} to form a planning target volume (PTV_{QBLT}), which largely improved tumor coverage from 75% (0mm margin) to 98% and the corresponding variation (n=10) of the tumor coverage was significantly reduced. Moreover, with prescribed dose 5Gy covering 95% of PTV_{QBLT}, QBLT-guided 7-field conformal RT can irradiate 99.4 \pm 1.0% of GTV vs. 65.5 \pm 18.5% with conventional single field irradiation (n=10). Our QBLT-guided system provides a unique opportunity for researchers to guide irradiation for soft tissue targets and increase rigorous and reproducibility of scientific discovery.
△ Less
Submitted 6 October, 2020;
originally announced October 2020.