Absolute quantum gravimeters and gradiometers for field measurements
Authors:
Laura Antoni-Micollier,
Maxime Arnal,
Romain Gautier,
Camille Janvier,
Vincent Ménoret,
Jérémie Richard,
Pierre Vermeulen,
Peter Rosenbusch,
Cédric Majek,
Bruno Desruelle
Abstract:
Gravity measurements provide valuable information on the mass distribution below the earth surface relevant to various areas of geosciences such as hydrology, geodesy, geophysics, volcanology, and natural resources management. During the past decades, the needs for sensitivity, robustness, compactness, and transportability of instruments measuring the gravitational acceleration have constantly inc…
▽ More
Gravity measurements provide valuable information on the mass distribution below the earth surface relevant to various areas of geosciences such as hydrology, geodesy, geophysics, volcanology, and natural resources management. During the past decades, the needs for sensitivity, robustness, compactness, and transportability of instruments measuring the gravitational acceleration have constantly increased. Today, applications typically call for 1 $μ\mathrm{Gal} = 10 \mathrm{nm.s}^{-2}$ ~ $10^{-9}$ g resolution on time scales ranging from minutes to years. Absolute Quantum Gravimeters (AQGs) based on matter-wave interferometry with laser-cooled atoms address all these challenges at once, even in uncontrolled environments. Furthermore, to date, quantum gravimeters are the only technology capable of providing continuous absolute gravity data over long measurement durations (~1 day to months or more). In this paper we recall the AQG working principle and present the reproducible high performance at the μGal level on all 16 units fabricated so far. We also describe recent progress on the Differential Quantum Gravimeter (DQG) which measures simultaneously the mean gravitational acceleration and its vertical gradient at the level of $10 \mathrm{nm.s}^{-2}$ and $1$ E (1 E[eotvos] = $10^{-9}$ s$^{-2}$) respectively.
△ Less
Submitted 17 May, 2024;
originally announced May 2024.
-
Atom interferometry at arbitrary orientations and rotation rates
Authors:
Quentin d'Armagnac de Castanet,
Cyrille Des Cognets,
Romain Arguel,
Simon Templier,
Vincent Jarlaud,
Vincent Ménoret,
Bruno Desruelle,
Philippe Bouyer,
Baptiste Battelier
Abstract:
The exquisite precision of atom interferometers has sparked the interest of a large community for use cases ranging from fundamental physics to geodesy and inertial navigation. However, their practical use for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift in free-fall atom interferometers, which makes the extraction of a…
▽ More
The exquisite precision of atom interferometers has sparked the interest of a large community for use cases ranging from fundamental physics to geodesy and inertial navigation. However, their practical use for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift in free-fall atom interferometers, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. Here we present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. An accurate model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using two fibre-optic gyroscopes and a tip-tilt platform to rotate the reference mirror and maintain the full contrast of the atom interferometer. Using these theoretical and practical tools, we reconstruct the fringes and demonstrate a single-shot sensitivity to acceleration of 24 $μ$g, for a total interrogation time of 2T = 20 ms, for angles and rotation rates reaching 30$^\circ$ and 14 $^\circ$/s respectively. Our hybrid rotating atom interferometer unlocks the full potential of quantum inertial sensors for onboard applications, such as autonomous navigation or gravity mapping.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
A compact differential gravimeter at the quantum projection noise limit
Authors:
Camille Janvier,
Vincent Ménoret,
Sébastien Merlet,
Arnaud Landragin,
Franck Pereira Dos Santos,
Bruno Desruelle
Abstract:
Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring simultaneously the absolute values of both gravitational acceleration, $g$, and its vertical gradient, $Γ_{zz}$. While the sensitivity to g is competitive with t…
▽ More
Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring simultaneously the absolute values of both gravitational acceleration, $g$, and its vertical gradient, $Γ_{zz}$. While the sensitivity to g is competitive with the best industrial gravimeters, the sensitivity on $Γ_{zz}$ reaches the limit set by quantum projection noise-leading to an unprecedented long-term stability of 0.1 E ($1E=1\times 10^{-9}s^{-2}$). This unique, dual-purpose instrument, paves the way for new applications in geophysics, civil engineering, and gravity-aided navigation, where accurate mapping of the gravitational field plays an important role.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
High power continuous laser at 461 nm based on a compact and high-efficiency frequency-doubling linear cavity
Authors:
Chen-Hao Feng,
Sébastien Vidal,
Paul Robert,
Philippe Bouyer,
Bruno Desruelle,
Marco Prevedelli,
Johan Boullet,
Giorgio Santarelli,
Andrea Bertoldi
Abstract:
A Watt-level continuous and single frequency blue laser at 461 nm is obtained by frequency-doubling an amplified diode laser operating at 922 nm via a LBO crystal in a resonant Fabry-Pérot cavity. We achieved a best optical conversion efficiency equal to 87\% with more than 1 W output power in the blue, and limited by the available input power. The frequency-converted beam is characterized in term…
▽ More
A Watt-level continuous and single frequency blue laser at 461 nm is obtained by frequency-doubling an amplified diode laser operating at 922 nm via a LBO crystal in a resonant Fabry-Pérot cavity. We achieved a best optical conversion efficiency equal to 87\% with more than 1 W output power in the blue, and limited by the available input power. The frequency-converted beam is characterized in terms of long term power stability, residual intensity noise, and geometrical shape. The blue beam has a linewidth of the order of 1 MHz, and we used it to magneto-optically trap $^{88}$Sr atoms on the 5s$^{2}\,^{1}$S$_0$ -- 5s5p$\,^{1}$P$_1$ transition. The low-finesse, linear-cavity doubling system is very robust, maintains the lock for several days, and is compatible with a tenfold increase of the power levels which could be obtained with fully-fibered amplifiers and large mode area fibers.
△ Less
Submitted 6 September, 2021; v1 submitted 14 June, 2021;
originally announced June 2021.
-
A fibered laser system for the MIGA large scale atom interferometer
Authors:
D. O. Sabulsky,
J. Junca,
G. Lefèvre,
X. Zou,
A. Bertoldi,
B. Battelier,
M. Prevedelli,
G. Stern,
J. Santoire,
Q. Beaufils,
R. Geiger,
A. Landragin,
B. Desruelle,
P. Bouyer,
B. Canuel
Abstract:
We describe the realization and characterization of a compact, autonomous fiber laser system that produces the optical frequencies required for laser cooling, trapping, manipulation, and detection of $^{87}$Rb atoms - a typical atomic species for emerging quantum technologies. This device, a customized laser system from the Muquans company, is designed for use in the challenging operating environm…
▽ More
We describe the realization and characterization of a compact, autonomous fiber laser system that produces the optical frequencies required for laser cooling, trapping, manipulation, and detection of $^{87}$Rb atoms - a typical atomic species for emerging quantum technologies. This device, a customized laser system from the Muquans company, is designed for use in the challenging operating environment of the Laboratoire Souterrain à Bas Bruit (LSBB) in France, where a new large scale atom interferometer is being constructed underground - the MIGA antenna. The mobile bench comprises four frequency-agile C-band Telecom diode lasers that are frequency doubled to 780 nm after passing through high-power fiber amplifiers. The first laser is frequency stabilized on a saturated absorption signal via lock-in amplification, which serves as an optical frequency reference for the other three lasers via optical phase-locked loops. Power and polarization stability are maintained through a series of custom, flexible micro-optic splitter/combiners that contain polarization optics, acousto-optic modulators, and shutters. Here, we show how the laser system is designed, showcasing qualities such as reliability, stability, remote control, and flexibility, while maintaining the qualities of laboratory equipment. We characterize the laser system by measuring the power, polarization, and frequency stability. We conclude with a demonstration using a cold atom source from the MIGA project and show that this laser system fulfills all requirements for the realization of the antenna.
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
First industrial-grade coherent fiber link for optical frequency standard dissemination
Authors:
F. Guillou-Camargo,
V. Ménoret,
E. Cantin,
O. Lopez,
N. Quintin,
E. Camisard,
V. Salmon,
J. -M. Le Merdy,
G. Santarelli,
A. Amy-Klein,
P. -E. Pottie,
B. Desruelle,
C. Chardonnet
Abstract:
We report on a fully bi-directional 680~km fiber link connecting two cities for which the equipment, the set up and the characterization are managed for the first time by an industrial consortium. The link uses an active telecommunication fiber network with parallel data traffic and is equipped with three repeater laser stations and four remote double bi-directional Erbium-doped fiber amplifiers.…
▽ More
We report on a fully bi-directional 680~km fiber link connecting two cities for which the equipment, the set up and the characterization are managed for the first time by an industrial consortium. The link uses an active telecommunication fiber network with parallel data traffic and is equipped with three repeater laser stations and four remote double bi-directional Erbium-doped fiber amplifiers. We report a short term stability at 1~s integration time of $5.4\times 10^{-16}$ in 0.5~Hz bandwidth and a long term stability of $1.7\times10^{-20}$ at 65\,000 s of integration time. The accuracy of the frequency transfer is evaluated as $3\times 10^{-20}$. No shift is observed within the statistical uncertainty. We show a continuous operation over 5 days with an uptime of 99.93$\%$. This performance is comparable with the state of the art coherent links established between National Metrology Institutes in Europe. It is a first step in the construction of an optical fiber network for metrology in France, which will give access to an ultra-high performance frequency standard to a wide community of scientific users.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
A prototype industrial laser system for cold atom inertial sensing in space
Authors:
Romain Caldani,
Sébastien Merlet,
Franck Pereira Dos Santos,
Guillaume Stern,
Anne-Sophie Martin,
Bruno Desruelle,
Vincent Ménoret
Abstract:
We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor current…
▽ More
We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor currently under development. The system reaches a Technology Readiness Level (TRL) of 4, corresponding to an operational validation in a controlled environment. The optical architecture of the system can be adapted to other space mission scenarios.
△ Less
Submitted 27 August, 2019;
originally announced August 2019.
-
Gravity measurements below $10^{-9}$ $g$ with a transportable absolute quantum gravimeter
Authors:
Vincent Ménoret,
Pierre Vermeulen,
Nicolas Le Moigne,
Sylvain Bonvalot,
Philippe Bouyer,
Arnaud Landragin,
Bruno Desruelle
Abstract:
Gravimetry is a well-established technique for the determination of sub-surface mass distribution needed in several fields of geoscience, and various types of gravimeters have been developed over the last 50 years. Among them, quantum gravimeters based on atom interferometry have shown top-level performance in terms of sensitivity, long-term stability and accuracy. Nevertheless, they have remained…
▽ More
Gravimetry is a well-established technique for the determination of sub-surface mass distribution needed in several fields of geoscience, and various types of gravimeters have been developed over the last 50 years. Among them, quantum gravimeters based on atom interferometry have shown top-level performance in terms of sensitivity, long-term stability and accuracy. Nevertheless, they have remained confined to laboratories due to their complex operation and high sensitivity to the external environment. Here we report on a novel, transportable, quantum gravimeter that can be operated under real world conditions by non-specialists, and measure the absolute gravitational acceleration continuously with a long-term stability below 10~nm.s$^{-2}$ (1~$μ$Gal). It features several technological innovations that allow for high-precision gravity measurements, while keeping the instrument light and small enough for field measurements. The instrument was characterized in detail and its stability was evaluated during a month-long measurement campaign.
△ Less
Submitted 13 September, 2018;
originally announced September 2018.
-
A study of atom localization in an optical lattice by analysis of the scattered light
Authors:
Christoph I Westbrook,
Christophe Jurczak,
Gerhard Birkl,
Bruno Desruelle,
William D. Phillips,
Alain Aspect
Abstract:
We present an experimental study of a four beam optical lattice using the light scattered by the atoms in the lattice. We use both intensity correlations and observations of the transient behavior of the scattering when the lattice is suddenly switched on. We compare results for 3 different configurations of the optical lattice. We create situations in which the Lamb-Dicke effect is negligible and…
▽ More
We present an experimental study of a four beam optical lattice using the light scattered by the atoms in the lattice. We use both intensity correlations and observations of the transient behavior of the scattering when the lattice is suddenly switched on. We compare results for 3 different configurations of the optical lattice. We create situations in which the Lamb-Dicke effect is negligible and show that, in contrast to what has been stated in some of the literature, the damping rate of the 'coherent' atomic oscillations can be much smaller than the inelastic photon scattering rate.
△ Less
Submitted 13 January, 2012;
originally announced January 2012.