-
Ultrastable vacuum-gap Fabry-Pérot cavities operated in air
Authors:
Yifan Liu,
Naijun Jin,
Dahyeon Lee,
Charles McLemore,
Takuma Nakamura,
Megan Kelleher,
Haotian Cheng,
Susan Schima,
Nazanin Hoghooghi,
Scott Diddams,
Peter Rakich,
Franklyn Quinlan
Abstract:
We demonstrate a vacuum-gap ultrastable optical reference cavity that does not require a vacuum enclosure. Our simple method of optical contact bonding in a vacuum environment allows for cavity operation in air while maintaining vacuum between the cavity mirrors. Vacuum is maintained long term, with no observed degradation in cavity stability for over 1 year after bonding. For a 1550 nm laser stab…
▽ More
We demonstrate a vacuum-gap ultrastable optical reference cavity that does not require a vacuum enclosure. Our simple method of optical contact bonding in a vacuum environment allows for cavity operation in air while maintaining vacuum between the cavity mirrors. Vacuum is maintained long term, with no observed degradation in cavity stability for over 1 year after bonding. For a 1550 nm laser stabilized to a 9.7 mL in-vacuum bonded cavity, the measured Allan deviation is $2.4\times 10^{-14}$ at 1 s and its phase noise is thermal-noise-limited from 0.1 Hz to 10 kHz, reaching about -105 dBc/Hz at 10 kHz offset frequency. This represents the highest stability of any oscillator operated without a vacuum enclosure. Furthermore, we demonstrate a 0.5 mL in-vacuum bonded cavity created using microfabricated mirrors and cavity dicing, with phase noise reaching -95 dBc/Hz at 10 kHz offset frequency. By relieving the need for high-vacuum enclosures, we greatly enhance the portability and utility of low noise, compact cavity-stabilized lasers, with applications ranging from environmental sensing to mobile optical clocks to ultralow noise microwave generation.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
A Novel Approach to Interface High-Q Fabry-Pérot Resonators with Photonic Circuits
Authors:
Haotian Cheng,
Naijun Jin,
Zhaowei Dai,
Chao Xiang,
Joel Guo,
Yishu Zhou,
Scott A. Diddams,
Franklyn Quinlan,
John Bowers,
Owen Miller,
Peter Rakich
Abstract:
The unique benefits of Fabry-Pérot resonators as frequency-stable reference cavities and as an efficient interface between atoms and photons make them an indispensable resource for emerging photonic technologies. To bring these performance benefits to next-generation communications, computation, and timekeeping systems, it will be necessary to develop strategies to integrate compact Fabry-Pérot re…
▽ More
The unique benefits of Fabry-Pérot resonators as frequency-stable reference cavities and as an efficient interface between atoms and photons make them an indispensable resource for emerging photonic technologies. To bring these performance benefits to next-generation communications, computation, and timekeeping systems, it will be necessary to develop strategies to integrate compact Fabry-Pérot resonators with photonic integrated circuits. In this paper, we demonstrate a novel reflection cancellation circuit that utilizes a numerically optimized multi-port polarization-splitting grating coupler to efficiently interface high-finesse Fabry-Pérot resonators with a silicon photonic circuit. This circuit interface produces spatial separation of the incident and reflected waves, as required for on-chip Pound-Drever-Hall frequency locking, while also suppressing unwanted back reflections from the Fabry-Pérot resonator. Using inverse design principles, we design and fabricate a polarization-splitting grating coupler that achieves 55% coupling efficiency. This design realizes an insertion loss of 5.8 dB for the circuit interface and more than 9 dB of back reflection suppression, and we demonstrate the versatility of this system by using it to interface several reflective off-chip devices.
△ Less
Submitted 18 October, 2023;
originally announced October 2023.
-
Photonic chip-based low noise microwave oscillator
Authors:
Igor Kudelin,
William Groman,
Qing-Xin Ji,
Joel Guo,
Megan L. Kelleher,
Dahyeon Lee,
Takuma Nakamura,
Charles A. McLemore,
Pedram Shirmohammadi,
Samin Hanifi,
Haotian Cheng,
Naijun Jin,
Sam Halliday,
Zhaowei Dai,
Lue Wu,
Warren Jin,
Yifan Liu,
Wei Zhang,
Chao Xiang,
Vladimir Iltchenko,
Owen Miller,
Andrey Matsko,
Steven Bowers,
Peter T. Rakich,
Joe C. Campbell
, et al. (4 additional authors not shown)
Abstract:
Numerous modern technologies are reliant on the low-phase noise and exquisite timing stability of microwave signals. Substantial progress has been made in the field of microwave photonics, whereby low noise microwave signals are generated by the down-conversion of ultra-stable optical references using a frequency comb. Such systems, however, are constructed with bulk or fiber optics and are diffic…
▽ More
Numerous modern technologies are reliant on the low-phase noise and exquisite timing stability of microwave signals. Substantial progress has been made in the field of microwave photonics, whereby low noise microwave signals are generated by the down-conversion of ultra-stable optical references using a frequency comb. Such systems, however, are constructed with bulk or fiber optics and are difficult to further reduce in size and power consumption. Our work addresses this challenge by leveraging advances in integrated photonics to demonstrate low-noise microwave generation via two-point optical frequency division. Narrow linewidth self-injection locked integrated lasers are stabilized to a miniature Fabry-Pérot cavity, and the frequency gap between the lasers is divided with an efficient dark-soliton frequency comb. The stabilized output of the microcomb is photodetected to produce a microwave signal at 20 GHz with phase noise of -96 dBc/Hz at 100 Hz offset frequency that decreases to -135 dBc/Hz at 10 kHz offset--values which are unprecedented for an integrated photonic system. All photonic components can be heterogeneously integrated on a single chip, providing a significant advance for the application of photonics to high-precision navigation, communication and timing systems.
△ Less
Submitted 17 July, 2023;
originally announced July 2023.
-
Thermal-noise-limited, compact optical reference cavity operated without a vacuum enclosure
Authors:
Yifan Liu,
Charles A. McLemore,
Megan Kelleher,
Dahyeon Lee,
Takuma Nakamura,
Naijun Jin,
Susan Schima,
Peter Rakich,
Scott A. Diddams,
Franklyn Quinlan
Abstract:
We present an in-vacuum bonded, 9.7 mL-volume Fabry-Pérot ultrastable optical reference cavity that operates without a vacuum enclosure. A laser stabilized to the cavity demonstrates low, thermal noise-limited phase noise and 5x10^{-14} Allan deviation at 1 second.
We present an in-vacuum bonded, 9.7 mL-volume Fabry-Pérot ultrastable optical reference cavity that operates without a vacuum enclosure. A laser stabilized to the cavity demonstrates low, thermal noise-limited phase noise and 5x10^{-14} Allan deviation at 1 second.
△ Less
Submitted 12 June, 2023;
originally announced July 2023.
-
Chip-Based Laser with 1 Hertz Integrated Linewidth
Authors:
Joel Guo,
Charles A. McLemore,
Chao Xiang,
Dahyeon Lee,
Lue Wu,
Warren Jin,
Megan Kelleher,
Naijun Jin,
David Mason,
Lin Chang,
Avi Feshali,
Mario Paniccia,
Peter T. Rakich,
Kerry J. Vahala,
Scott A. Diddams,
Franklyn Quinlan,
John E. Bowers
Abstract:
Lasers with hertz-level linewidths on timescales up to seconds are critical for precision metrology, timekeeping, and manipulation of quantum systems. Such frequency stability typically relies on bulk-optic lasers and reference cavities, where increased size is leveraged to improve noise performance, but with the trade-off of cost, hand assembly, and limited application environments. On the other…
▽ More
Lasers with hertz-level linewidths on timescales up to seconds are critical for precision metrology, timekeeping, and manipulation of quantum systems. Such frequency stability typically relies on bulk-optic lasers and reference cavities, where increased size is leveraged to improve noise performance, but with the trade-off of cost, hand assembly, and limited application environments. On the other hand, planar waveguide lasers and cavities exploit the benefits of CMOS scalability but are fundamentally limited from achieving hertz-level linewidths at longer times by stochastic noise and thermal sensitivity inherent to the waveguide medium. These physical limits have inhibited the development of compact laser systems with frequency noise required for portable optical clocks that have performance well beyond conventional microwave counterparts. In this work, we break this paradigm to demonstrate a compact, high-coherence laser system at 1548 nm with a 1 s integrated linewidth of 1.1 Hz and fractional frequency instability less than 10$^{-14}$ from 1 ms to 1 s. The frequency noise at 1 Hz offset is suppressed by 11 orders of magnitude from that of the free-running diode laser down to the cavity thermal noise limit near 1 Hz$^2$/Hz, decreasing to 10$^{-3}$ Hz$^2$/Hz at 4 kHz offset. This low noise performance leverages wafer-scale integrated lasers together with an 8 mL vacuum-gap cavity that employs micro-fabricated mirrors with sub-angstrom roughness to yield an optical $Q$ of 11.8 billion. Significantly, all the critical components are lithographically defined on planar substrates and hold the potential for parallel high-volume manufacturing. Consequently, this work provides an important advance towards compact lasers with hertz-level linewidths for applications such as portable optical clocks, low-noise RF photonic oscillators, and related communication and navigation systems.
△ Less
Submitted 30 March, 2022;
originally announced March 2022.
-
Micro-fabricated mirrors with finesse exceeding one million
Authors:
Naijun Jin,
Charles A. McLemore,
David Mason,
James P. Hendrie,
Yizhi Luo,
Megan L. Kelleher,
Prashanta Kharel,
Franklyn Quinlan,
Scott A. Diddams,
Peter T. Rakich
Abstract:
The Fabry-Pérot resonator is one of the most widely used optical devices, enabling scientific and technological breakthroughs in diverse fields including cavity QED, optical clocks, precision length metrology and spectroscopy. Though resonator designs vary widely, all high-end applications benefit from mirrors with the lowest loss and highest finesse possible. Fabrication of the highest finesse mi…
▽ More
The Fabry-Pérot resonator is one of the most widely used optical devices, enabling scientific and technological breakthroughs in diverse fields including cavity QED, optical clocks, precision length metrology and spectroscopy. Though resonator designs vary widely, all high-end applications benefit from mirrors with the lowest loss and highest finesse possible. Fabrication of the highest finesse mirrors relies on centuries-old mechanical polishing techniques, which offer losses at the part-per-million (ppm) level. However, no existing fabrication techniques are able to produce high finesse resonators with the large range of mirror geometries needed for scalable quantum devices and next-generation compact atomic clocks. In this paper, we introduce a new and scalable approach to fabricate mirrors with ultrahigh finesse ($\geq 10^{6}$) and user-defined radius of curvature spanning four orders of magnitude ($10^{-4}-10^{0}$ m). We employ photoresist reflow and reactive ion etching to shape and transfer mirror templates onto a substrate while maintaining sub-Angstrom roughness. This substrate is coated with a dielectric stack and used to create arrays of compact Fabry-Pérot resonators with finesse values as high as 1.3 million and measured excess loss $<$ 1 ppm. Optical ringdown measurements of 43 devices across 5 substrates reveal that the fabricated cavity mirrors -- with both small and large radii of curvature -- produce an average coating-limited finesse of 1.05 million. This versatile new approach opens the door to scalable fabrication of high-finesse miniaturized Fabry-Pérot cavities needed for emerging quantum optics and frequency metrology technologies.
△ Less
Submitted 7 June, 2022; v1 submitted 29 March, 2022;
originally announced March 2022.
-
Thermal noise-limited laser stabilization to an 8 mL volume Fabry-Pérot reference cavity with microfabricated mirrors
Authors:
Charles A. McLemore,
Naijun Jin,
Megan L. Kelleher,
James P. Hendrie,
David Mason,
Yizhi Luo,
Dahyeon Lee,
Peter Rakich,
Scott A. Diddams,
Franklyn Quinlan
Abstract:
Lasers stabilized to vacuum-gap Fabry-Pérot optical reference cavities display extraordinarily low noise and high stability, with linewidths much less than 1 Hz. These lasers can expand into new applications and ubiquitous use with the development of compact, portable cavities that are manufacturable at scale. Here we demonstrate an 8 mL volume Fabry-Pérot cavity constructed with mirrors that are…
▽ More
Lasers stabilized to vacuum-gap Fabry-Pérot optical reference cavities display extraordinarily low noise and high stability, with linewidths much less than 1 Hz. These lasers can expand into new applications and ubiquitous use with the development of compact, portable cavities that are manufacturable at scale. Here we demonstrate an 8 mL volume Fabry-Pérot cavity constructed with mirrors that are fabricated lithographically with finesse near 1 million. A laser locked to the cavity exhibits phase noise limited by the cavity thermal noise for offset frequencies ranging from 1 Hz to $\approx$ 1 kHz, with a fractional frequency stability of 7$\times$10$^{-15}$ at 1 second. Furthermore, the use of microfabricated mirrors allows us to expand the design space of centimeter-scale cavities, and we explore the noise implications of pushing towards cavity volumes of 2 mL or less.
△ Less
Submitted 29 March, 2022;
originally announced March 2022.
-
Influence of portal vein occlusion on portal flow and liver elasticity in an animal model
Authors:
Simon Chatelin,
Raoul Pop,
Céline Giraudeau,
Khalid Ambarki,
Ning Jin,
François Severac,
Elodie Breton,
Jonathan Vappou
Abstract:
Hepatic fibrosis causes an increase in liver stiffness, a parameter measured by elastography and widely used as a diagnosis method. The concomitant presence of portal vein thrombosis (PVT) implies a change in hepatic portal inflow that could also affect liver elasticity. The main objective of this study is to determine the extent to which the presence of portal occlusion can affect the mechanical…
▽ More
Hepatic fibrosis causes an increase in liver stiffness, a parameter measured by elastography and widely used as a diagnosis method. The concomitant presence of portal vein thrombosis (PVT) implies a change in hepatic portal inflow that could also affect liver elasticity. The main objective of this study is to determine the extent to which the presence of portal occlusion can affect the mechanical properties of the liver and potentially lead to misdiagnosis of fibrosis and hepatic cirrhosis by elastography. Portal vein occlusion was generated by insertion and inflation of a balloon catheter in the portal vein of four swines. The portal flow parameters peak flow (PF) and peak velocity magnitude (PVM) and liver mechanical properties (shear modulus) were then investigated using 4D-flow MRI and MR elastography, respectively, for progressive obstructions of the portal vein. Experimental results indicate that the reduction of the intrahepatic venous blood flow (PF/PVM decreases of 29.3%/8.5%, 51.0%/32.3% and 83.3%/53.6%, respectively) measured with 50%, 80% and 100% obstruction of the portal vein section results in a decrease of liver stiffness by $0.8\%\pm0.1\%$, $7.7\%\pm0.4\%$ and $12.3\%\pm0.9\%$, respectively. While this vascular mechanism does not have sufficient influence on the elasticity of the liver to modify the diagnosis of severe fibrosis or cirrhosis (F4 METAVIR grade), it may be sufficient to attenuate the increase in stiffness due to moderate fibrosis (F2-F3 METAVIR grades) and consequently lead to false-negative diagnoses with elastography in the presence of PVT.
△ Less
Submitted 12 March, 2021;
originally announced March 2021.
-
Magnetic Resonance Elastography and Portal Hypertension: Influence of the Portal Venous Flow on the Liver Stiffness
Authors:
Simon Chatelin,
Raoul Pop,
Céline Giraudeau,
Khalid Ambarki,
Ning Jin,
François Severac,
Elodie Breton,
Jonathan Vappou
Abstract:
The invasive measurement of the hepatic venous pressure gradient is still considered as the reference method to assess the severity of portal hypertension. Even though previous studies have shown that the liver stiffness measured by elastography could predict portal hypertension in patients with chronic liver disease, the mechanisms behind remain today poorly understood. The main reason is that th…
▽ More
The invasive measurement of the hepatic venous pressure gradient is still considered as the reference method to assess the severity of portal hypertension. Even though previous studies have shown that the liver stiffness measured by elastography could predict portal hypertension in patients with chronic liver disease, the mechanisms behind remain today poorly understood. The main reason is that the liver stiffness is not specific to portal hypertension and is also influenced by concomitant pathologies, such as cirrhosis. Portal hypertension is also source of a vascular incidence, with a substantial diversion of portal venous blood to the systemic circulation, bypassing the liver. This study focuses on this vascular effect of portal hypertension. We propose to generate and control the portal venous flow (to isolate the modifications in the portal venous flow as single effect of portal hypertension) in an anesthetized pig and then to quantify its implications on liver stiffness by an original combination of MRE and 4D-Flow Magnetic Resonance Imaging (MRI). A catheter balloon is progressively inflated in the portal vein and the peak flow, peak velocity magnitude and liver stiffness are quantified in a 1.5T MRI scanner (AREA, Siemens Healthcare, Erlangen, Germany). A strong correlation is observed between the portal peak velocity magnitude, the portal peak flow or the liver stiffness and the portal vein intraluminal obstruction. Moreover, the comparison of mechanical and flow parameters highlights a correlation with the possibility of identifying linear relationships. These results give preliminary indications about how liver stiffness can be affected by portal venous flow and, by extension, by hypertension.
△ Less
Submitted 7 December, 2020;
originally announced December 2020.
-
422 Million Q Planar Integrated All-Waveguide Resonator with a 3.4 Billion Absorption Limited Q and Sub-MHz Linewidth
Authors:
Matthew W. Puckett,
Kaikai Liu,
Nitesh Chauhan,
Qiancheng Zhao,
Naijun Jin,
Haotian Cheng,
Jianfeng Wu,
Ryan O. Behunin,
Peter T. Rakich,
Karl D. Nelson,
Daniel J. Blumenthal
Abstract:
High Q optical resonators are a key component for ultra-narrow linewidth lasers, frequency stabilization, precision spectroscopy and quantum applications. Integration of these resonators in a photonic waveguide wafer-scale platform is key to reducing their cost, size and power as well as sensitivity to environmental disturbances. However, to date, the intrinsic Q of integrated all-waveguide resona…
▽ More
High Q optical resonators are a key component for ultra-narrow linewidth lasers, frequency stabilization, precision spectroscopy and quantum applications. Integration of these resonators in a photonic waveguide wafer-scale platform is key to reducing their cost, size and power as well as sensitivity to environmental disturbances. However, to date, the intrinsic Q of integrated all-waveguide resonators has been relegated to below 150 Million. Here, we report an all-waveguide Si3N4 resonator with an intrinsic Q of 422 Million and a 3.4 Billion absorption loss limited Q. The resonator has a 453 kHz intrinsic linewidth and 906 kHz loaded linewidth, with a finesse of 3005. The corresponding linear loss of 0.060 dB/m is the lowest reported to date for an all-waveguide design with deposited upper cladding oxide. These are the highest intrinsic and absorption loss limited Q factors and lowest linewidth reported to date for a photonic integrated all-waveguide resonator. This level of performance is achieved through a careful reduction of scattering and absorption loss components. We quantify, simulate and measure the various loss contributions including scattering and absorption including surface-state dangling bonds that we believe are responsible in part for absorption. In addition to the ultra-high Q and narrow linewidth, the resonator has a large optical mode area and volume, both critical for ultra-low laser linewidths and ultra-stable, ultra-low frequency noise reference cavities. These results demonstrate the performance of bulk optic and etched resonators can be realized in a photonic integrated solution, paving the way towards photonic integration compatible Billion Q cavities for precision scientific systems and applications such as nonlinear optics, atomic clocks, quantum photonics and high-capacity fiber communications systems on-chip.
△ Less
Submitted 15 September, 2020;
originally announced September 2020.
-
Realization of two-dimensional crystal of ions in a monolithic Paul trap
Authors:
Ye Wang,
Mu Qiao,
Zhengyang Cai,
Kuan Zhang,
Naijun Jin,
Pengfei Wang,
Wentao Chen,
Chunyang Luan,
Haiyan Wang,
Yipu Song,
Dahyun Yum,
Kihwan Kim
Abstract:
We present a simple Paul trap that stably accommodates up to a couple of dozens of \ensuremath{^{171}\mathrm{Yb}^+~} ions in a stationary two-dimensional lattice. The trap is constructed on a single plate of gold-plated laser-machined alumina and can produce a pancake-like pseudo-potential that makes ions form a self-assembly two-dimensional crystal which locates on the plane composed of axial and…
▽ More
We present a simple Paul trap that stably accommodates up to a couple of dozens of \ensuremath{^{171}\mathrm{Yb}^+~} ions in a stationary two-dimensional lattice. The trap is constructed on a single plate of gold-plated laser-machined alumina and can produce a pancake-like pseudo-potential that makes ions form a self-assembly two-dimensional crystal which locates on the plane composed of axial and one of the transverse axes with around 5 $μ$m spacing. We use Raman laser beams to coherently manipulate these ion-qubits where the net propagation direction is perpendicular to the plane of the crystal and micromotion. We perform the coherent operations and study the spectrum of vibrational modes through globally addressed Raman laser-beams on a dozen of ions in the two-dimensional crystal. We measure the amplitude of micro-motion by comparing the strengths of carrier and micro-motion sideband transitions with three ions, where the micro-motion amplitude is similar to that of a single ion. The spacings of ions are small enough for large coupling strengths, which is a favorable condition for two-dimensional quantum simulation.
△ Less
Submitted 10 December, 2019; v1 submitted 9 December, 2019;
originally announced December 2019.
-
Frequency stabilization of a 650 nm laser to I$_{2}$ spectrum for trapped $^{138}$Ba$^{+}$ ions
Authors:
Tian Xie,
Naijun Jin,
Ye Wang,
Junhua Zhang,
Mark Um,
Pengfei Wang,
Kihwan Kim
Abstract:
The optical manipulation of Ba$^{+}$ ions is mainly performed by a 493 nm laser for the S$_{1/2}$-P$_{1/2}$ transition and a 650 nm laser for the P$_{1/2}$-D$_{3/2}$ transition. Since the branching ratio between the 493 nm and 650 nm transitions of a single Ba$^{+}$ ion is comparable, stabilization systems of both lasers are equally important for Doppler cooling, sub-Doppler cooling, optical pumpi…
▽ More
The optical manipulation of Ba$^{+}$ ions is mainly performed by a 493 nm laser for the S$_{1/2}$-P$_{1/2}$ transition and a 650 nm laser for the P$_{1/2}$-D$_{3/2}$ transition. Since the branching ratio between the 493 nm and 650 nm transitions of a single Ba$^{+}$ ion is comparable, stabilization systems of both lasers are equally important for Doppler cooling, sub-Doppler cooling, optical pumping and state detection. The stabilization system of a 493 nm laser to an absolute Te$_2$ reference has been well established. However, the stabilization of a 650 nm laser has not been presented before. Here we report twenty spectral lines of I$_{2}$ in the range of 0.9 GHz above the resonance of the P$_{1/2}$-D$_{3/2}$ transition. We stabilize the 650 nm laser through the optical cavity to the lowest one among these lines, which is about 350 MHz apart, as the absolute frequency reference. Furthermore, we measure the frequency differences between these iodine lines and the Ba$^+$ resonance through fluorescence excitation spectrum with well-resolved dark states, which is in agreement with the theoretical expectation. The presented stabilization scheme enables us to perform precise experiments with Ba$^{+}$ ions.
△ Less
Submitted 15 May, 2018;
originally announced May 2018.