MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
L. García Ordóñez,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri
, et al. (7 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly de…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly developed MPGD-based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a Micromegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during the 2016 COMPASS data taking and stably operated during the 2017 run. In this paper design, construction, operation and performance aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also indicated.
△ Less
Submitted 20 July, 2019;
originally announced July 2019.
-
The Hybrid MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buechele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai
, et al. (6 additional authors not shown)
Abstract:
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution o…
▽ More
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
Letter of Intent: A New QCD facility at the M2 beam line of the CERN SPS (COMPASS++/AMBER)
Authors:
B. Adams,
C. A. Aidala,
R. Akhunzyanov,
G. D. Alexeev,
M. G. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
A. Antoshkin,
K. Augsten,
W. Augustyniak,
C. D. R. Azevedo,
A. Azhibekov,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Berenguer Antequera,
J. C. Bernauer,
J. Bernhard,
M. Bodlak,
P. Bordalo
, et al. (242 additional authors not shown)
Abstract:
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
△ Less
Submitted 25 January, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also presented.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Maggiora,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri
, et al. (10 additional authors not shown)
Abstract:
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination…
▽ More
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors
Authors:
M. Alexeev,
R Birsa,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fishcher,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
K. Koenigsmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri,
F. A. Pereira
, et al. (10 additional authors not shown)
Abstract:
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are describe…
▽ More
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.
△ Less
Submitted 25 October, 2017;
originally announced October 2017.
-
Novel MPGD based Detectors of Single Photons in COMPASS RICH-1
Authors:
J. Agarwala M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy
, et al. (12 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly dev…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 24 October, 2017;
originally announced October 2017.
-
The COMPASS Setup for Physics with Hadron Beams
Authors:
Ph. Abbon,
C. Adolph,
R. Akhunzyanov,
Yu. Alexandrov,
M. G. Alexeev,
G. D. Alexeev,
A. Amoroso,
V. Andrieux,
V. Anosov,
A. Austregesilo,
B. Badelek,
F. Balestra,
J. Barth,
G. Baum,
R. Beck,
Y. Bedfer,
A. Berlin,
J. Bernhard,
K. Bicker,
E. R. Bielert,
J. Bieling,
R. Birsa,
J. Bisplinghoff,
M. Bodlak,
M. Boer
, et al. (207 additional authors not shown)
Abstract:
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well…
▽ More
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.
△ Less
Submitted 7 October, 2014;
originally announced October 2014.