-
Fast Small-Angle X-ray Scattering Tensor Tomography: An Outlook into Future Applications in Life Sciences
Authors:
Christian Appel,
Margaux Schmeltz,
Irene Rodriguez-Fernandez,
Lukas Anschuetz,
Leonard C. Nielsen,
Ezequiel Panepucci,
Tomislav Marijolovic,
Klaus Wakonig,
Aleksandra Ivanovic,
Anne Bonnin,
Filip Leonarski,
Justyna Wojdyla,
Takashi Tomizaki,
Manuel Guizar-Sicairos,
Kate Smith,
John H. Beale,
Wayne Glettig,
Katherine McAuley,
Oliver Bunk,
Meitian Wang,
Marianne Liebi
Abstract:
Small Angle-X-ray Scattering Tensor Tomography (SAS-TT) is a relatively new, but powerful technique for studying the multiscale architecture of hierarchical structures, which is of particular interest for life science applications. Currently, the technique is very demanding on synchrotron beamtime, which limits its applications, especially for cases requiring a statistically relevant amount of sam…
▽ More
Small Angle-X-ray Scattering Tensor Tomography (SAS-TT) is a relatively new, but powerful technique for studying the multiscale architecture of hierarchical structures, which is of particular interest for life science applications. Currently, the technique is very demanding on synchrotron beamtime, which limits its applications, especially for cases requiring a statistically relevant amount of sample. This study reports the first SAS-TT measurement at a macromolecular X-ray crystallography beamline, PX-I at the SLS, with an improvement in data acquisition time from 96 h/Mvoxel in the pilot experiments to 6 h/Mvoxel, defining a new standard for fast SAS-TT and allowing the measurement of a full tomogram in 1.2 hours. Measurements were performed on the long and lenticular process of the incus bone, one of the three human auditory ossicles. The main orientation and degree of alignment of the mineralised collagen fibrils are characterised, as well as the size and shape of the mineral particles which show relevant variations in different tissue locations. The study reveals three distinct regions of high fibril alignment, most likely important pathways of sound throughout the ossicular chain, and highlights the potential of the technique to aid in future developments in middle ear reconstructive surgery.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Monitoring dynamic collagen reorganization during skin stretching with fast polarization-resolved second harmonic generation imaging
Authors:
Guillaume Ducourthial,
Jean-sébastien Affagard,
Margaux Schmeltz,
Xavier Solinas,
Maeva Lopez-poncelas,
Christelle Bonod-bidaud,
Ruth Rubio-amador,
Florence Ruggiero,
Jean-Marc Allain,
Emmanuel Beaurepaire,
Marie-claire Schanne-klein
Abstract:
The mechanical properties of biological tissues are strongly correlated to the specific distribution of their collagen fibers. Monitoring the dynamic reorganization of the collagen network during mechanical stretching is however a technical challenge because it requires mapping orientation of collagen fibers in a thick and deforming sample. In this work, a fast polarization-resolved SHG microscope…
▽ More
The mechanical properties of biological tissues are strongly correlated to the specific distribution of their collagen fibers. Monitoring the dynamic reorganization of the collagen network during mechanical stretching is however a technical challenge because it requires mapping orientation of collagen fibers in a thick and deforming sample. In this work, a fast polarization-resolved SHG microscope is implemented to map collagen orientation during mechanical assays. This system is based on line-to-line switching of polarization using an electro-optical modulator and works in epidetection geometry. After proper calibration, it successfully highlights the collagen dynamic alignment along the traction direction in ex vivo murine skin dermis. This microstructure reorganization is quantified by the entropy of the collagen orientation distribution as a function of the stretch ratio. It exhibits a linear behavior, whose slope is measured with a good accuracy. This approach can be generalized to probe a variety of dynamic processes in thick tissues.
△ Less
Submitted 19 April, 2019;
originally announced April 2019.
-
9 GeV Energy Gain in a Beam-Driven Plasma Wakefield Accelerator
Authors:
M Litos,
E Adli,
J M Allen,
W An,
C I Clarke,
S Corde,
C E Clayton,
J Frederico,
S J Gessner,
S Z Green,
M J Hogan,
C Joshi,
W. Lu,
K A Marsh,
W B Mori,
M Schmeltz,
N Vafaei-Najafabadi,
V Yakimenko
Abstract:
An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an accelerati…
▽ More
An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an acceleration gradient of 4.0 GeV/m at the spectral peak. The mean energy spread of the data set was 5.1%. These results are consistent with the extrapolation of the previously reported energy gain results using a shorter, 36 cm-long plasma source to within 10%, evincing a non-evolving wake structure that can propagate distances of over a meter in length. Wake-loading effects were evident in the data through strong dependencies observed between various spectral properties and the amount of accelerated charge.
△ Less
Submitted 20 November, 2015;
originally announced November 2015.