-
A multi-reflection time-of-flight mass spectrometer for the offline ion source of the PUMA experiment
Authors:
M. Schlaich,
J. Fischer,
P. Fischer,
C. Klink,
A. Obertelli,
A. Schmidt,
L. Schweikhard,
F. Wienholtz
Abstract:
The antiProton Unstable Matter Annihilation experiment (PUMA) at CERN aims at investigating the nucleon composition in the matter density tail of radioactive as well as stable isotopes by use of low-energy antiproton-nucleon annihilation processes. For this purpose, antiprotons provided by the Extra Low ENergy Antiproton (ELENA) facility will be trapped together with the ions of interest. While ex…
▽ More
The antiProton Unstable Matter Annihilation experiment (PUMA) at CERN aims at investigating the nucleon composition in the matter density tail of radioactive as well as stable isotopes by use of low-energy antiproton-nucleon annihilation processes. For this purpose, antiprotons provided by the Extra Low ENergy Antiproton (ELENA) facility will be trapped together with the ions of interest. While exotic ions will be obtained by the Isotope mass Separator On-Line DEvice (ISOLDE), stable ions will be delivered from an offline ion source setup designed for this purpose. This allows the proposed technique to be applied to a variety of stable nuclei and for reference measurements. For beam purification, the ion source setup includes a multi-reflection time-of-flight mass spectrometer (MR-ToF MS). Supported by SIMION simulations, an earlier MR-ToF MS design has been modified to meet the requirements of PUMA. During commissioning of the new MR-ToF device with Ar$^+$ ions, mass resolving powers in excess of 50,000 have been obtained after 150 revolutions, limited by the chopping of the continuous beam from an electron impact ionisation source.
△ Less
Submitted 7 November, 2023;
originally announced November 2023.
-
In-source and in-trap formation of molecular ions in the actinide mass range at CERN-ISOLDE
Authors:
M. Au,
M. Athanasakis-Kaklamanakis,
L. Nies,
J. Ballof,
R. Berger,
K. Chrysalidis,
P. Fischer,
R. Heinke,
J. Johnson,
U. Köster,
D. Leimbach,
B. Marsh,
M. Mougeot,
J. Reilly,
E. Reis,
M. Schlaich,
Ch. Schweiger,
L. Schweikhard,
S. Stegemann,
J. Wessolek,
F. Wienholtz,
S. G. Wilkins,
W. Wojtaczka,
Ch. E. Düllmann,
S. Rothe
Abstract:
The use of radioactive molecules for fundamental physics research is a developing interdisciplinary field limited dominantly by their scarce availability. In this work, radioactive molecular ion beams containing actinide nuclei extracted from uranium carbide targets are produced via the Isotope Separation On-Line technique at the CERN-ISOLDE facility. Two methods of molecular beam production are s…
▽ More
The use of radioactive molecules for fundamental physics research is a developing interdisciplinary field limited dominantly by their scarce availability. In this work, radioactive molecular ion beams containing actinide nuclei extracted from uranium carbide targets are produced via the Isotope Separation On-Line technique at the CERN-ISOLDE facility. Two methods of molecular beam production are studied: extraction of molecular ion beams from the ion source, and formation of molecular ions from the mass-separated ion beam in a gas-filled radio-frequency quadrupole ion trap. Ion currents of U$^+$, UO$_{1-3}^+$, UC$_{1-3}^+$, UF$_{1-4}^+$, UF$_{1,2}$O$_{1,2}^+$ are reported. Metastable tantalum and uranium fluoride molecular ions are identified. Formation of UO$_{1-3}^+$, U(OH)$_{1-3}^+$, UC$_{1-3}^+$, UF$_{1,2}$O$_{1,2}^+$ from mass-separated beams of U$^+$, UF$_{1,2}^+$ with residual gas is observed in the ion trap. The effect of trapping time on molecular formation is presented.
△ Less
Submitted 21 March, 2023;
originally announced March 2023.
-
A versatile setup for studying size and charge-state selected polyanionic nanoparticles
Authors:
K. Raspe,
M. Müller,
N. Iwe,
R. N. Wolf,
P. Oelßner,
F. Martinez,
L. Schweikhard,
K. -H. Meiwes-Broer,
J. Tiggesbäumker
Abstract:
Using the example of metal clusters, an experimental setup and procedure is presented, which allows for the generation of size and charge-state selected polyanions from monoanions in a molecular beam. As a characteristic feature of this modular setup, the further charging process via sequential electron attachment within a 3-state digital trap takes place after mass-selection. In contrast to other…
▽ More
Using the example of metal clusters, an experimental setup and procedure is presented, which allows for the generation of size and charge-state selected polyanions from monoanions in a molecular beam. As a characteristic feature of this modular setup, the further charging process via sequential electron attachment within a 3-state digital trap takes place after mass-selection. In contrast to other approaches, the rf based concept permits to access heavy particles. The procedure is highly flexible with respect to the preparation process and potentially suitable for a wide variety of anionic species. By adjusting the storage conditions, i.e., the radio frequency, to the change in the mass-to-charge ratio, we succeeded to produce clusters in highly negative charge states, i.e., Ag$_{800}^{7-}$. The capabilities of the setup are demonstrated by experiments extracting electronic and optical properties of polyanionic metal clusters by analyzing the corresponding photoelectron spectra.
△ Less
Submitted 17 January, 2022;
originally announced January 2022.
-
Stacked-Ring Ion Guide for Cooling and Bunching Rare Isotopes
Authors:
X. Chen,
J. Even,
P. Fischer,
M. Schlaich,
T. Schlathölter,
L. Schweikhard,
A. Soylu
Abstract:
In modern rare isotope facilities, ion cooling and bunching lies at the heart of the ion transfer along a low-energy beam line that consists of several differential pumping stages. We present a conceptual design of an ion guide as an alternative to the conventional linear Radio-Frequency Quadrupole (RFQ) for cooling and bunching rare isotopes. The ion guide is composed of stacked ring electrodes o…
▽ More
In modern rare isotope facilities, ion cooling and bunching lies at the heart of the ion transfer along a low-energy beam line that consists of several differential pumping stages. We present a conceptual design of an ion guide as an alternative to the conventional linear Radio-Frequency Quadrupole (RFQ) for cooling and bunching rare isotopes. The ion guide is composed of stacked ring electrodes of varying apertures, to which a confining RF potential following a rectangular waveform is applied. The thicknesses of the rings and the gaps in between are varied accordingly to maximize the confining volume and to reduce ion losses. Ion transport within the ion guide is facilitated by a lower-frequency wave traveling on top of the higher-frequency confining field. The former is induced by locally adjusting the duty cycle of the rectangular waveform of the confining potential. Design parameters are first calculated by analytical studies and then optimized by ion trajectory simulations with SIMION. The results show that the ion guide enables high ion transmission and produces well focused ion bunches. It will be used in the NEXT project, an experimental study of atomic masses of Neutron-rich EXotic nuclei produced in multi-nucleon Transfer reactions.
△ Less
Submitted 15 March, 2022; v1 submitted 9 January, 2022;
originally announced January 2022.
-
Long-term monitoring of the internal energy distribution of isolated cluster systems
Authors:
Christian Breitenfeldt,
Klaus Blaum,
Sebastian George,
Jürgen Göck,
Gregorio Guzmán-Ramírez,
Jonas Karthein,
Thomas Kolling,
Michael Lange,
Sebastian Menk,
Christian Meyer,
Jennifer Mohrbach,
Gereon Niedner-Schatteburg,
Dirk Schwalm,
Lutz Schweikhard,
Andreas Wolf
Abstract:
A method is presented to monitor the internal energy distribution of cluster anions via delayed electron detachment by pulsed photoexcitation and demonstrated on Co$_4{}^-$ in an electrostatic ion beam trap. In cryogenic operation, we calibrate the detachment delay to internal energy. By laser frequency scans, at room temperature, we reconstruct the time-dependent internal energy distribution of t…
▽ More
A method is presented to monitor the internal energy distribution of cluster anions via delayed electron detachment by pulsed photoexcitation and demonstrated on Co$_4{}^-$ in an electrostatic ion beam trap. In cryogenic operation, we calibrate the detachment delay to internal energy. By laser frequency scans, at room temperature, we reconstruct the time-dependent internal energy distribution of the clusters. The mean energies of ensembles from a cold and a hot ion source both approach thermal equilibrium. Our data yield a radiative emission law and the absorptivity of the cluster for thermal radiation.
△ Less
Submitted 29 May, 2018;
originally announced May 2018.
-
Radiative rotational lifetimes and state-resolved relative detachment cross sections from photodetachment thermometry of molecular anions in a cryogenic storage ring
Authors:
C. Meyer,
A. Becker,
K. Blaum,
C. Breitenfeldt,
S. George,
J. Göck,
M. Grieser,
F. Grussie,
E. A. Guerin,
R. von Hahn,
P. Herwig,
C. Krantz,
H. Kreckel,
J. Lion,
S. Lohmann,
P. M. Mishra,
O. Novotný,
A. P. O'Connor,
R. Repnow,
S. Saurabh,
D. Schwalm,
L. Schweikhard,
K. Spruck,
S. Sunil Kumar,
S. Vogel
, et al. (1 additional authors not shown)
Abstract:
Photodetachment thermometry on a beam of OH$^-$ in a cryogenic storage ring cooled to below 10 K is carried out using two-dimensional, frequency and time dependent photodetachment spectroscopy over 20 minutes of ion storage. In equilibrium with the low-level blackbody field, we find an effective radiative temperature near 15 K with about 90% of all ions in the rotational ground state. We measure t…
▽ More
Photodetachment thermometry on a beam of OH$^-$ in a cryogenic storage ring cooled to below 10 K is carried out using two-dimensional, frequency and time dependent photodetachment spectroscopy over 20 minutes of ion storage. In equilibrium with the low-level blackbody field, we find an effective radiative temperature near 15 K with about 90% of all ions in the rotational ground state. We measure the J = 1 natural lifetime (about 193 s) and determine the OH$^-$ rotational transition dipole moment with 1.5% uncertainty. We also measure rotationally dependent relative near-threshold photodetachment cross sections for photodetachment thermometry.
△ Less
Submitted 16 July, 2017;
originally announced July 2017.
-
The Cryogenic Storage Ring CSR
Authors:
Robert von Hahn,
Arno Becker,
Felix Berg,
Klaus Blaum,
Christian Breitenfeldt,
Hisham Fadil,
Florian Fellenberger,
Michael Froese,
Sebastian George,
Jürgen Göck,
Manfred Grieser,
Florian Grussie,
Elisabeth A. Guerin,
Oded Heber,
Philipp Herwig,
Jonas Karthein,
Claude Krantz,
Holger Kreckel,
Michael Lange,
Felix Laux,
Svenja Lohmann,
Sebastian Menk,
Christian Meyer,
Preeti M. Mishra,
Oldřich Novotný
, et al. (19 additional authors not shown)
Abstract:
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage ti…
▽ More
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion) and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm$^{-3}$ is derived, equivalent to a room-temperature pressure below 10$^{-14}$ mbar. Fast atomic, molecular and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.
△ Less
Submitted 5 June, 2016;
originally announced June 2016.
-
Direct determination of the atomic mass difference of Re187 and Os187 for neutrino physics and cosmochronology
Authors:
D. A. Nesterenko,
S. Eliseev,
K. Blaum,
M. Block,
S. Chenmarev,
A. Doerr,
C. Droese,
P. E. Filianin,
M. Goncharov,
E. Minaya Ramirez,
Yu. N. Novikov,
L. Schweikhard,
V. V. Simon
Abstract:
For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discre…
▽ More
For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained value of 2492(30stat)(15sys) eV is in excellent agreement with the Q values determined indirectly with microcalorimetry and thus resolves a long-standing discrepancy with older proportional counter measurements. This is essential for the determination of the neutrino mass from the beta-decay of 187Re as planned in future microcalorimetric measurements. In addition, an accurate mass difference of 187Re and 187Os is also important for the assessment of 187Re for cosmochronology.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination
Authors:
S. Eliseev,
K. Blaum,
M. Block,
S. Chenmarev,
H. Dorrer,
Ch. E. Duellmann,
C. Enss,
P. E. Filianin,
L. Gastaldo,
M. Goncharov,
U. Koester,
F. Lautenschlaeger,
Yu. N. Novikov,
A. Rischka,
R. X. Schuessler,
L. Schweikhard,
A. Tuerler
Abstract:
The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q…
▽ More
The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 sigma to 2833(30stat)(15sys) eV/c2. With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.
△ Less
Submitted 14 April, 2016;
originally announced April 2016.
-
Electric and magnetic field optimization procedure for Penning trap mass spectrometers
Authors:
D. Beck,
K. Blaum,
G. Bollen,
P. Delahaye,
S. George,
C. Guenaut,
F. Herfurth,
A. Herlert,
D. Lunney,
L. Schweikhard,
C. Yazidjian
Abstract:
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency a…
▽ More
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.
△ Less
Submitted 29 May, 2008;
originally announced May 2008.
-
The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results
Authors:
S. George,
K. Blaum,
F. Herfurth,
A. Herlert,
M. Kretzschmar,
S. Nagy,
S. Schwarz,
L. Schweikhard,
C. Yazidjian
Abstract:
The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has b…
▽ More
The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has been shown to reduce significantly the uncertainty in the determination of the cyclotron frequency and thus of the ion mass of interest. The theoretical description of the ion motion excited with Ramsey's method in a Penning trap and subsequently the calculation of the resonance line shapes for different excitation times, pulse structures, and detunings of the quadrupole field has been carried out in a quantum mechanical framework and is discussed in detail in the preceding article in this journal by M. Kretzschmar. Here, the new excitation technique has been applied with the ISOLTRAP mass spectrometer at ISOLDE/CERN for mass measurements on stable as well as short-lived nuclides. The experimental resonances are in agreement with the theoretical predictions and a precision gain close to a factor of four was achieved compared to the use of the conventional excitation technique.
△ Less
Submitted 22 January, 2007;
originally announced January 2007.
-
Magnetic field stabilization for high-accuracy mass measurements on exotic nuclides
Authors:
M. Marie-Jeanne,
J. Alonso,
K. Blaum,
S. Djekic,
M. Dworschak,
U. Hager,
A. Herlert,
Sz. Nagy,
R. Savreux,
L. Schweikhard,
S. Stahl,
C. Yazidjian
Abstract:
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pre…
▽ More
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the fluctuations by at least one order of magnitude downto dT=+/-5mK and dp=+/-50mtorr has been achieved, which corresponds to a relative frequency change of 2.7x10^{-9} and 1.5x10^{-10}, respectively. With this stabilization the frequency determination with the Penning trap only shows a linear temporal drift over several hours on the 10 ppb level due to the finite resistance of the superconducting magnet coils.
△ Less
Submitted 19 January, 2007;
originally announced January 2007.
-
Multiply charged metal cluster anions
Authors:
Constantine Yannouleas,
Uzi Landman,
Alexander Herlert,
Lutz Schweikhard
Abstract:
Formation, stability patterns, and decay channels of silver dianionic and gold trianionic clusters are investigated with Penning-trap experiments and a shell-correction method including shape deformations. The theoretical predictions pertaining to the appearance sizes and electronic shell effects are in remarkable agreement with the experiments. Decay of the multiply anionic clusters occurs pred…
▽ More
Formation, stability patterns, and decay channels of silver dianionic and gold trianionic clusters are investigated with Penning-trap experiments and a shell-correction method including shape deformations. The theoretical predictions pertaining to the appearance sizes and electronic shell effects are in remarkable agreement with the experiments. Decay of the multiply anionic clusters occurs predominantly by electron tunneling through a Coulomb barrier, rather than via fission, leading to appearance sizes unrelated to those of multiply cationic clusters.
△ Less
Submitted 12 December, 2000;
originally announced December 2000.