-
On the space resolution of the $μ$-RWELL
Authors:
G. Bencivenni,
G. Cibinetto,
R. de Oliveira,
R. Farinelli,
G. Felici,
M. Gatta,
M. Giovannetti,
L. Lavezzi,
G. Morello,
A. Ochi,
M. Poli Lener,
E. Tskhadadze
Abstract:
In MPGD detectors evaluation of the space resolution with the charge centroid (CC) method provides large uncertainty when the impinging particle is not perpendicular to the readout plane. An improvement of the position reconstruction, and thus of the space resolution, is represented by the $μ$TPC algorithm. In this work we report the application of this algorithm to the $μ$-Resistive WELL detector…
▽ More
In MPGD detectors evaluation of the space resolution with the charge centroid (CC) method provides large uncertainty when the impinging particle is not perpendicular to the readout plane. An improvement of the position reconstruction, and thus of the space resolution, is represented by the $μ$TPC algorithm. In this work we report the application of this algorithm to the $μ$-Resistive WELL detector. Moreover a combination of the CC method with the $μ$TPC algorithm is proposed, showing an almost uniform resolution over a wide angular range.
△ Less
Submitted 7 July, 2020;
originally announced July 2020.
-
Triple GEM performance in magnetic field
Authors:
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferroli,
I. Balossino,
G. Bencivenni,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
A. Calcaterra,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
G. Cotto,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
D. Domenici
, et al. (43 additional authors not shown)
Abstract:
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is…
▽ More
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is capable to guarantee a spatial resolution better than 150μmin magnetic field up to a 1 T.
△ Less
Submitted 17 August, 2019;
originally announced August 2019.
-
GRAAL: Gem Reconstruction And Analysis Library
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. BaldiniFerroli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (25 additional authors not shown)
Abstract:
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysi…
▽ More
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterized; tracking,where a procedure fits the points from the tracking system and uses that information to align thechamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency,spatial resolution,etc.). The user must set the geometry of the setup and then the programreturns automatically the analysis results, taking care of different conditions of gas mixture,electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and manyothers.
△ Less
Submitted 8 May, 2019;
originally announced May 2019.
-
A fast and parametric digitization for triple-GEM detectors
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferrioli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (26 additional authors not shown)
Abstract:
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the…
▽ More
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.
-
The micro-RWELL layouts for high particle rate
Authors:
G. Bencivenni,
R. de Oliveira,
G. Felici,
M. Gatta,
M. Giovannetti,
G. Morello,
A. Ochi,
M. Poli Lener,
E. Tskhadadze
Abstract:
The $μ$-RWELL is a single-amplification stage resistive Micro-Pattern Gaseous Detector (MPGD). The detector amplification element is realized with a single copper-clad polyimide foil micro-patterned with a blind hole (well) matrix and embedded in the readout PCB through a thin Diamond-Like-Carbon (DLC) sputtered resistive film. The introduction of the resistive layer, suppressing the transition fr…
▽ More
The $μ$-RWELL is a single-amplification stage resistive Micro-Pattern Gaseous Detector (MPGD). The detector amplification element is realized with a single copper-clad polyimide foil micro-patterned with a blind hole (well) matrix and embedded in the readout PCB through a thin Diamond-Like-Carbon (DLC) sputtered resistive film. The introduction of the resistive layer, suppressing the transition from streamer to spark, allows to achieve large gains ($\geq$10$^4$) with a single amplification stage, while partially reducing the capability to stand high particle fluxes. The simplest resistive layout, designed for low-rate applications, is based on a single-resistive layer with edge grounding. At high particle fluxes this layout suffers of a non-uniform response. In order to get rid of such a limitation different current evacuation geometries have been designed. In this work we report the study of the performance of several high rate resistive layouts tested at the CERN H8-SpS and PSI $π$M1 beam test facilities. These layouts fulfill the requirements for the detectors at the HL-LHC and for the experiments at the next generation colliders FCC-ee/hh and CepC.
△ Less
Submitted 30 April, 2019; v1 submitted 26 March, 2019;
originally announced March 2019.
-
Innovative design and construction technique for the Cylindrical GEM detector for the BESIII experiment
Authors:
A. Amoroso,
M. Alexeev,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti,
I. Garzia
, et al. (27 additional authors not shown)
Abstract:
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the particles and to exploit the its properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allow to creat…
▽ More
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the particles and to exploit the its properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allow to create very large area GEM foils (up to 50x100 cm2) and thanks to the small thickness of these foil is it possible to shape it to the desired form: a Cylindrical Gas Electron Multiplier (CGEM) is then proposed. The innovative construction technique based on Rohacell, a PMI foam, will give solidity to cathode and anode with a very low impact on material budget. The entire detector is sustained by permaglass rings glued at the edges. These rings are use to assembly the CGEM together with a dedicated Vertical Insertion System and moreover there is placed the On-Detector electronic. The anode has been improved w.r.t. the state of the art through a jagged readout that minimize the inter-strip capacitance. The mechanical challenge of this detector requires a precision of the entire geometry within few hundreds of microns in the whole area. In this presentation will be presented an overview of the construction technique and the validation of this technique through the realization of a CGEM and its first tests. These activities are performed within the framework of the BESIIICGEM Project (645664), funded by the European Commission in the action H2020-RISE-MSCA-2014.
△ Less
Submitted 21 March, 2018;
originally announced March 2018.
-
Test beam results of a Cylindrical GEM detector for the BESIII experiment
Authors:
G. Mezzadri,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti
, et al. (28 additional authors not shown)
Abstract:
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged particles and to exploit their properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allows t…
▽ More
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged particles and to exploit their properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allows to create very large area GEM foils (up to 50x100 $\mathrm{cm}^2$) and thanks to the small thickness of these foils is it possible to shape it to the desired form: a Cylindrical Gas Electron Multiplier (CGEM) is then proposed. The innovative construction technique based on Rohacell, a PMI foam, will give solidity to cathode and anode with a very low impact on material budget. The entire detector is sustained by Permaglass rings glued at the edges. These rings are used to assembly the CGEM, together with a dedicated Vertical Insertion System and moreover they host the On-Detector electronic. The anode has been improved w.r.t. the state of the art through a jagged readout that minimize the inter-strip capacitance. The mechanical challenge of this detector requires a precision of the entire geometry within few hundreds of microns in the whole area. In this contribution an overview of the construction technique, the validation of this technique through the realization of a CGEM, and its first tests will be presented. These activities are performed within the framework of the BESIIICGEM Project (645664), funded by the European Commission in the action H2020-RISE-MSCA-2014.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
Performance of the micro-TPC Reconstruction for GEM Detectors at High Rate
Authors:
L. Lavezzi,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti
, et al. (27 additional authors not shown)
Abstract:
Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors, as drift chambers and microstrips, reducing the discharge rate and increasing the radiation tolerance. Among these, one of the most commonly used is the Gas Elec…
▽ More
Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors, as drift chambers and microstrips, reducing the discharge rate and increasing the radiation tolerance. Among these, one of the most commonly used is the Gas Electron Multiplier. Commonly deployed as fast timing detectors and triggers, due to their fast response, high rate capability and high radiation hardness, they can also be used as trackers. The center of gravity readout technique allows to overcome the limit of the digital pads, whose spatial resolution is constrained by the pitch size. The presence of a high external magnetic field can distort the electronic cloud and affect the spatial resolution. The micro-TPC reconstruction method allows to reconstruct the three dimensional particle position as in a traditional Time Projection Chamber, but within a drift gap of a few millimeters. This method brings these detectors into a new perspective for what concerns the spatial resolution in strong magnetic field. In this report, the basis of this new technique will be shown and it will be compared to the traditional center of gravity. The results of a series of test beam performed with 10 x 10 cm2 planar prototypes in magnetic field will also be presented. This is one of the first implementations of this technique for GEM detectors in magnetic field and allows to reach unprecedented performance for gas detectors, up to a limit of 120 micron at 1T, one of the world's best results for MPGDs in strong magnetic field. The micro-TPC reconstruction has been recently tested at very high rates in a test beam at the MAMI facility; preliminary results of the test will be presented.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
Test beam results with prototypes for the new Cylindrical GEM Inner Tracker of the BESIII experiment
Authors:
L. Lavezzi,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti
, et al. (27 additional authors not shown)
Abstract:
A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150 GeV/c momentum, to evaluate the efficiency and resolution under different working conditions. The obtained efficiency was in the 96 - 98% range. Two complementary…
▽ More
A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150 GeV/c momentum, to evaluate the efficiency and resolution under different working conditions. The obtained efficiency was in the 96 - 98% range. Two complementary algorithms for the position determination were developed: the charge centroid and the micro-TPC methods. With the former, resolutions <100 micron and <200 micron were achieved without and with magnetic field, respectively. The micro-TPC improved these results. By the end of 2016, the first cylindrical prototype was tested on the same beam line. It showed optimal stability under different settings. The comparison of its performance with respect to the planar chambers is ongoing. Here, the results of the planar prototype tests will be addressed.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
The new cylindrical GEM inner tracker of BESIII
Authors:
L. Lavezzi,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti
, et al. (27 additional authors not shown)
Abstract:
The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detectors, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a…
▽ More
The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detectors, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a 1T magnetic field. The simultaneous measurement of both the deposited charge and the signal time will permit to use a combination of two algorithms to evaluate the spatial position of the charged tracks inside the CGEM-IT: the charge centroid and the micro time projection chamber modes. They are complementary and can cope with the asymmetry of the electron avalanche when running in magnetic field and with non-orthogonal incident tracks. To evaluate the behavior under different working settings, both planar chambers and the first cylindrical prototype have been tested during various test beams at CERN with 150 GeV/c muons and pions. This paper reports the results obtained with the two reconstruction methods and a comparison between the planar and cylindrical chambers.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
The Cylindrical GEM Inner Tracker of the BESIII experiment: prototype test beam results
Authors:
L. Lavezzi,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti
, et al. (27 additional authors not shown)
Abstract:
A cylindrical GEM detector is under development, to serve as an upgraded inner tracker at the BESIII spectrometer. It will consist of three layers of cylindrically-shaped triple GEMs surrounding the interaction point. The experiment is taking data at the e+e- collider BEPCII in Beijing (China) and the GEM tracker will be installed in 2018. Tests on the performances of triple GEMs in strong magneti…
▽ More
A cylindrical GEM detector is under development, to serve as an upgraded inner tracker at the BESIII spectrometer. It will consist of three layers of cylindrically-shaped triple GEMs surrounding the interaction point. The experiment is taking data at the e+e- collider BEPCII in Beijing (China) and the GEM tracker will be installed in 2018. Tests on the performances of triple GEMs in strong magnetic field have been run by means of the muon beam available in the H4 line of SPS (CERN) with both planar chambers and the first cylindrical prototype. Efficiencies and resolutions have been evaluated using different gains, gas mixtures, with and without magnetic field. The obtained efficiency is 97-98% on single coordinate view, in many operational arrangements. The spatial resolution for planar GEMs has been evaluated with two different algorithms for the position determination: the charge centroid and the micro time projection chamber (mu-TPC) methods. The two modes are complementary and are able to cope with the asymmetry of the electron avalanche when running in magnetic field, and with non-orthogonal incident tracks. With the charge centroid, a resolution lower than 100 micron has been reached without magnetic field and lower than 200 micron with a magnetic field up to 1 T. The mu-TPC mode showed to be able to improve those results. In the first beam test with the cylindrical prototype, the detector had a very good stability under different voltage configurations and particle intensities. The resolution evaluation is in progress.
△ Less
Submitted 3 July, 2017; v1 submitted 7 June, 2017;
originally announced June 2017.
-
A custom readout electronics for the BESIII CGEM detector
Authors:
M. Da Rocha Rolo,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
R. Bugalho,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
A. Di Francesco,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava
, et al. (31 additional authors not shown)
Abstract:
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 um while loosening the pitch strip to 650 um, which allows to…
▽ More
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 um while loosening the pitch strip to 650 um, which allows to reduce the total number of channels to about 10 000. The channels are readout by 160 dedicated integrated 64-channel front-end ASICs, providing a time and charge measurement and featuring a fully-digital output. The energy measurement is extracted either from the time-over-threshold (ToT) or the 10-bit digitisation of the peak amplitude of the signal. The time of the event is generated by quad-buffered low-power TDCs, allowing for rates in excess of 60 kHz per channel. The TDCs are based on analogue interpolation techniques and produce a time stamp (or two, if working in ToT mode) of the event with a time resolution better than 50 ps. The front-end noise, based on a CSA and CR-RC2 shapers, dominate the channel intrinsic time jitter, which is less than 5 ns r.m.s.. The time information of the hit can be used to reconstruct the track path, operating the detector as a small TPC and hence improving the position resolution when the distribution of the cloud, due to large incident angle or magnetic field, is very broad. Event data is collected by an off-detector motherboard, where each GEM-ROC readout card handles 4 ASIC carrier PCBs (512 channels). Configuration upload and data readout between the off-detector electronics and the VME-based data collector cards are managed by bi-directional fibre optical links.
△ Less
Submitted 28 June, 2017; v1 submitted 7 June, 2017;
originally announced June 2017.