-
GRAPH -- An readout ASIC for large MCP based detectors
Authors:
Andrej Seljak,
John Vallerga,
Gang Liu,
Rick Raffanti,
Gary S. Varner
Abstract:
We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming p…
▽ More
We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA), a mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few~kHz up to 125~MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130~$n$m TSMC CMOS technology, and its power consumption is around 47~$m$W per channel.
△ Less
Submitted 16 June, 2024;
originally announced June 2024.
-
Calibration and Physics with ARA Station 1: A Unique Askaryan Radio Array Detector
Authors:
M. F. H Seikh,
D. Z. Besson,
S. Ali,
P. Allison,
S. Archambault,
J. J. Beatty,
A. Bishop,
P. Chen,
Y. C. Chen,
B. A. Clark,
W. Clay,
A. Connolly,
K. Couberly,
L. Cremonesi,
A. Cummings,
P. Dasgupta,
R. Debolt,
S. De Kockere,
K. D. de Vries,
C. Deaconu,
M. A. DuVernois,
J. Flaherty,
E. Friedman,
R. Gaior,
P. Giri
, et al. (48 additional authors not shown)
Abstract:
The Askaryan Radio Array Station 1 (A1), the first among five autonomous stations deployed for the ARA experiment at the South Pole, is a unique ultra-high energy neutrino (UHEN) detector based on the Askaryan effect that uses Antarctic ice as the detector medium. Its 16 radio antennas (distributed across 4 strings, each with 2 Vertically Polarized (VPol), 2 Horizontally Polarized (HPol) receivers…
▽ More
The Askaryan Radio Array Station 1 (A1), the first among five autonomous stations deployed for the ARA experiment at the South Pole, is a unique ultra-high energy neutrino (UHEN) detector based on the Askaryan effect that uses Antarctic ice as the detector medium. Its 16 radio antennas (distributed across 4 strings, each with 2 Vertically Polarized (VPol), 2 Horizontally Polarized (HPol) receivers), and 2 strings of transmitting antennas (calibration pulsers, CPs), each with 1 VPol and 1 HPol channel, are deployed at depths less than 100 m within the shallow firn zone of the 2.8 km thick South Pole (SP) ice. We apply different methods to calibrate its Ice Ray Sampler second generation (IRS2) chip for timing offset and ADC-to-Voltage conversion factors using a known continuous wave input signal to the digitizer, and achieve a precision of sub-nanoseconds. We achieve better calibration for odd, compared to even samples, and also find that the HPols under-perform relative to the VPol channels. Our timing calibrated data is subsequently used to calibrate the ADC-to-Voltage conversion as well as precise antenna locations, as a precursor to vertex reconstruction. The calibrated data will then be analyzed for UHEN signals in the final step of data compression. The ability of A1 to scan the firn region of SP ice sheet will contribute greatly towards a 5-station analysis and will inform the design of the planned IceCube Gen-2 radio array.
△ Less
Submitted 14 August, 2023;
originally announced August 2023.
-
Snowmass 2021 White Paper on Upgrading SuperKEKB with a Polarized Electron Beam: Discovery Potential and Proposed Implementation
Authors:
A. Accardi,
D. M. Asner,
H. Atmacan,
R. Baartman,
Sw. Banerjee,
A. Beaubien,
J. V. Bennett,
M. Bertemes,
M. Bessner,
D. Biswas,
G. Bonvicini,
N. Brenny,
R. A. Briere,
T. E. Browder,
C. Chen,
S. Choudhury,
D. Cinabro,
J. Cochran,
L. M. Cremaldi,
W. Deconinck,
A. Di Canto,
S. Dubey,
K. Flood,
B. G. Fulsom,
V. Gaur
, et al. (83 additional authors not shown)
Abstract:
Upgrading the SuperKEKB electron-positron collider with polarized electron beams opens a new program of precision physics at a center-of-mass energy of 10.58 GeV. This white paper describes the physics potential of this `Chiral Belle' program. It includes projections for precision measurements of $\sin^2θ_W$ that can be obtained from independent left-right asymmetry measurements of $e^+e^-$ transi…
▽ More
Upgrading the SuperKEKB electron-positron collider with polarized electron beams opens a new program of precision physics at a center-of-mass energy of 10.58 GeV. This white paper describes the physics potential of this `Chiral Belle' program. It includes projections for precision measurements of $\sin^2θ_W$ that can be obtained from independent left-right asymmetry measurements of $e^+e^-$ transitions to pairs of electrons, muons, taus, charm and b-quarks. The $\sin^2θ_W$ precision obtainable at SuperKEKB will match that of the LEP/SLC world average, but at the centre-of-mass energy of 10.58 GeV. Measurements of the couplings for muons, charm, and $b$-quarks will be substantially improved and the existing $3σ$ discrepancy between the SLC $A_{LR}$ and LEP $A_{FB}^b$ measurements will be addressed. Precision measurements of neutral current universality will be more than an order of magnitude more precise than currently available. As the energy scale is well away from the $Z^0$-pole, the precision measurements will have sensitivity to the presence of a parity-violating dark sector gauge boson, $Z_{\rm dark}$. The program also enables the measurement of the anomalous magnetic moment $g-2$ form factor of the $τ$ to be made at an unprecedented level of precision. A precision of $10^{-5}$ level is accessible with 40~ab$^{-1}$ and with more data it would start to approach the $10^{-6}$ level. This technique would provide the most precise information from the third generation about potential new physics explanations of the muon $g-2$ $4σ$ anomaly. Additional $τ$ and QCD physics programs enabled or enhanced with having polarized electron beams are also discussed in this White Paper. This paper includes a summary of the path forward in R&D and next steps required to implement this upgrade and access its exciting discovery potential.
△ Less
Submitted 13 September, 2022; v1 submitted 25 May, 2022;
originally announced May 2022.
-
Enhanced low-energy supernova burst detection in large liquid argon time projection chambers enabled by Q-Pix
Authors:
S. Kubota,
J. Ho,
A. D. McDonald,
N. Tata,
J. Asaadi,
R. Guenette,
J. B. R. Battat,
D. Braga,
M. Demarteau,
Z. Djurcic,
M. Febbraro,
E. Gramellini,
S. Kohani,
C. Mauger,
Y. Mei,
F. M. Newcomer,
K. Nishimura,
D. Nygren,
R. Van Berg,
G. S. Varner,
K. Woodworth
Abstract:
The detection of neutrinos from core-collapse supernovae may reveal important process features as well as neutrino properties. The detection of supernova neutrinos is one of the main science drivers for future kiloton-scale neutrino detectors based on liquid argon. Here we show that for such detectors the intrinsically 3D readout in Q-Pix offers numerous advantages relative to a wire-based readout…
▽ More
The detection of neutrinos from core-collapse supernovae may reveal important process features as well as neutrino properties. The detection of supernova neutrinos is one of the main science drivers for future kiloton-scale neutrino detectors based on liquid argon. Here we show that for such detectors the intrinsically 3D readout in Q-Pix offers numerous advantages relative to a wire-based readout, such as higher reconstruction efficiency, lower energy threshold, considerably lower data rates, and potential pointing information.
△ Less
Submitted 12 August, 2022; v1 submitted 22 March, 2022;
originally announced March 2022.
-
Precision timing for collider-experiment-based calorimetry
Authors:
S. V. Chekanov,
F. Simon,
V. Boudry,
W. Chung,
P. W. Gorham,
M. Nguyen,
C. G. Tully,
S. C. Eno,
Y. Lai,
A. V. Kotwal,
S. Ko,
I. Laktineh,
S. Lee,
J. S. H. Lee,
M. T. Lucchini,
R. Prechelt,
H. Yoo,
C. -H Yeh,
S. -S. Yu,
G. S. Varner,
R. Zhu
Abstract:
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the f…
▽ More
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the full detector volume, and dedicated timing layers integrated in calorimeter systems. A selection of technologies for the different approaches is also discussed.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
STOPGAP -- a Time-of-Flight Extension for the Belle II TOP Barrel PID System as a Demonstrator for CMOS Fast Timing Sensors
Authors:
Oskar Hartbrich,
Umberto Tamponi,
Gary S. Varner
Abstract:
The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system based on sixteen fused-silica bars arranged around the interaction point acting as Cherenkov radiator. Due to the mechanical design of the TOP system these quartz bars do not overlap, but leave a gap of around 2cm between them. This leads to around 6% of all tracks in the nominal TOP accept…
▽ More
The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system based on sixteen fused-silica bars arranged around the interaction point acting as Cherenkov radiator. Due to the mechanical design of the TOP system these quartz bars do not overlap, but leave a gap of around 2cm between them. This leads to around 6% of all tracks in the nominal TOP acceptance region to escape without traversing any of the quartz bars and thus not giving any usable particle identification information from the TOP system and an additional 3% of tracks being degraded due to edge effects. We propose a possible solution to remedy these gaps in the TOP acceptance in the form of a Supplemental TOP GAP instrumentation (STOPGAP) that covers the dead area between adjacent quartz bars with fast silicon detectors to directly measure the time-of-flight of traversing particles for particle identification purposes. Modern, fast timing silicon sensors and readouts can offer sufficient time resolution for the task at hand, so that STOPGAP modules could be built compact enough to fit into the limited space available in the area of interest between the Belle II central drift chamber (CDC) and the TOP system.
In this article, we present a simulation study demonstrating the feasibility of a silicon time-of-flight system based on its reconstruction performance in $Υ(4S)\rightarrow B\bar{B}$ events simulated using the Belle II simulation and reconstruction software. We discuss the performance requirements for possible sensor technologies and demonstrate that such a project could be realised with novel, fast monolithic CMOS sensors that are expected to reach MIP timing resolutions of down to 50ps. Additionally, we discuss the use of fast timing layers at lower radii for track triggering as well as particle identification at low momenta <1GeV/c.
△ Less
Submitted 9 March, 2022;
originally announced March 2022.
-
Picosecond Timing-Planes for Future Collider Detectors
Authors:
P. W. Gorham,
C. Campos,
C. Hast,
K. Jobe,
C. Miki,
L. Nguyen,
M. Olmedo,
R. Prechelt,
C. Sonoda,
G. S. Varner
Abstract:
We report experimental test-beam results on dielectric-loaded waveguide detectors that utilize microwave Cherenkov signals to time and characterize high energy particle showers. These results are used to validate models and produce high-fidelity simulations of timing plane systems which yield picosecond time tags and millimeter spatial coordinates for the shower centroid. These timing planes, base…
▽ More
We report experimental test-beam results on dielectric-loaded waveguide detectors that utilize microwave Cherenkov signals to time and characterize high energy particle showers. These results are used to validate models and produce high-fidelity simulations of timing plane systems which yield picosecond time tags and millimeter spatial coordinates for the shower centroid. These timing planes, based on the Askaryan effect in solid dielectrics, are most effective at the high center-of-momentum energies planned for the Future Circular Collider (FCC-hh), and are of particular interest in the forward region due to their high radiation immunity. We use our beam test results and GEANT4 simulations to validate a hybrid microwave detector model, which is used to simulate a reference timing plane design for the FCC forward calorimeters. Our results indicate that 0.5-3 ps particle timing is possible for a wide range of collision products in the reference FCC hadron collider detector, even with current technology.
△ Less
Submitted 10 February, 2022; v1 submitted 1 December, 2021;
originally announced December 2021.
-
The Payload for Ultrahigh Energy Observations (PUEO): A White Paper
Authors:
Q. Abarr,
P. Allison,
J. Ammerman Yebra,
J. Alvarez-Muñiz,
J. J. Beatty,
D. Z. Besson,
P. Chen,
Y. Chen,
J. M. Clem,
A. Connolly,
L. Cremonesi,
C. Deaconu,
J. Flaherty,
D. Frikken,
P. W. Gorham,
C. Hast,
C. Hornhuber,
J. J. Huang,
K. Hughes,
A. Hynous,
Y. Ku,
C. -Y. Kuo,
T. C. Liu,
Z. Martin,
C. Miki
, et al. (25 additional authors not shown)
Abstract:
The Payload for Ultrahigh Energy Observations (PUEO) long-duration balloon experiment is designed to have world-leading sensitivity to ultrahigh-energy neutrinos at energies above 1 EeV. Probing this energy region is essential for understanding the extreme-energy universe at all distance scales. PUEO leverages experience from and supersedes the successful Antarctic Impulsive Transient Antenna (ANI…
▽ More
The Payload for Ultrahigh Energy Observations (PUEO) long-duration balloon experiment is designed to have world-leading sensitivity to ultrahigh-energy neutrinos at energies above 1 EeV. Probing this energy region is essential for understanding the extreme-energy universe at all distance scales. PUEO leverages experience from and supersedes the successful Antarctic Impulsive Transient Antenna (ANITA) program, with an improved design that drastically improves sensitivity by more than an order of magnitude at energies below 30 EeV. PUEO will either make the first significant detection of or set the best limits on ultrahigh-energy neutrino fluxes.
△ Less
Submitted 20 September, 2021; v1 submitted 6 October, 2020;
originally announced October 2020.
-
Studies of MCP-PMTs in the miniTimeCube neutrino detector
Authors:
V. A. Li,
J. Koblanski,
R. Dorrill,
M. J. Duvall,
K. Engel,
G. R. Jocher,
J. G. Learned,
S. Matsuno,
W. F. McDonough,
H. P. Mumm,
S. Negrashov,
K. Nishimura,
M. Rosen,
M. Sakai,
S. M. Usman,
G. S. Varner,
S. A. Wipperfurth
Abstract:
This report highlights two different types of cross-talk in the photodetectors of the miniTimeCube neutrino experiment. The miniTimeCube detector has 24 $8 \times 8$-anode Photonis MCP-PMTs Planacon XP85012, totalling 1536 individual pixels viewing the 2-liter cube of plastic scintillator.
This report highlights two different types of cross-talk in the photodetectors of the miniTimeCube neutrino experiment. The miniTimeCube detector has 24 $8 \times 8$-anode Photonis MCP-PMTs Planacon XP85012, totalling 1536 individual pixels viewing the 2-liter cube of plastic scintillator.
△ Less
Submitted 21 September, 2018;
originally announced September 2018.
-
LAB4D: A Low Power, Multi-GSa/s, Transient Digitizer with Sampling Timebase Trimming Capabilities
Authors:
Jarred M. Roberts,
Eric Oberla,
Patrick Allison,
Gary S. Varner,
Stefan Spack,
Brendan Fox,
Ben Rotter
Abstract:
The LAB4D is a new application-specific integrated circuit (ASIC) of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) family, for use in direct wideband radio frequency digitization such as is used in ultrahigh energy neutrino and cosmic ray astrophysics. The LAB4D is a single channel switched-capacitor array (SCA) 12-bit sampler with integrated analog-to-digital c…
▽ More
The LAB4D is a new application-specific integrated circuit (ASIC) of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) family, for use in direct wideband radio frequency digitization such as is used in ultrahigh energy neutrino and cosmic ray astrophysics. The LAB4D is a single channel switched-capacitor array (SCA) 12-bit sampler with integrated analog-to-digital converters (ADC), developed in the TSMC 0.25um process. The LAB4D, operating at 3.2GSa/s, contains 4096 total samples arranged in 32 windows, for a total record length of 1280ns. The 3dB bandwidth is approximately 1.3GHz, with a directly-coupled 50ohm input. This represents a factor of 16 increase in the sample depth and an increase in analog bandwidth and sampling depth in comparison to the previous generation LAB3 digitizer. Individually addressable windows allow for sampling and digitization to occur simultaneously, leading to nearly deadtime-free readout for kHz readout rates. All biases and current references are generated via internal digital-to-analog converters (DACs), resulting in a stand-alone digitizer with no additional support circuitry. In addition, the LAB4D contains sample cell timebase trimming capabilities, reducing the intrinsic sample-to-sample time variance to less than 5ps; an improvement of about 80%. This allows the LAB4D to be used in precision timing applications with minimal post-hoc calibration.
△ Less
Submitted 20 February, 2019; v1 submitted 12 March, 2018;
originally announced March 2018.
-
HiCal 2: An instrument designed for calibration of the ANITA experiment and for Antarctic surface reflectivity measurements
Authors:
S. Prohira,
A. Novikov,
D. Z. Besson,
K. Ratzlaff,
J. Stockham,
M. Stockham,
J. M. Clem,
R. Young,
P. W. Gorham,
P. Allison,
O. Banerjee,
L. Batten,
J. J. Beatty,
K. Belov,
W. R. Binns,
V. Bugaev,
P. Cao,
C. Chen,
P. Chen,
A. Connolly,
L. Cremonesi,
B. Dailey,
C. Deaconu,
P. F. Dowkontt,
B. D. Fox
, et al. (33 additional authors not shown)
Abstract:
The NASA supported High-Altitude Calibration (HiCal)-2 instrument flew as a companion balloon to the ANITA-4 experiment in December 2016. Based on a HV discharge pulser producing radio-frequency (RF) calibration pulses, HiCal-2 comprised two payloads, which flew for a combined 18 days, covering 1.5 revolutions of the Antarctic continent. ANITA-4 captured over 10,000 pulses from HiCal, both direct…
▽ More
The NASA supported High-Altitude Calibration (HiCal)-2 instrument flew as a companion balloon to the ANITA-4 experiment in December 2016. Based on a HV discharge pulser producing radio-frequency (RF) calibration pulses, HiCal-2 comprised two payloads, which flew for a combined 18 days, covering 1.5 revolutions of the Antarctic continent. ANITA-4 captured over 10,000 pulses from HiCal, both direct and reflected from the surface, at distances varying from 100-800 km, providing a large dataset for surface reflectivity measurements. Herein we present details on the design, construction and performance of HiCal-2.
△ Less
Submitted 17 September, 2020; v1 submitted 30 October, 2017;
originally announced October 2017.
-
Picosecond timing of Microwave Cherenkov Impulses from High-Energy Particle Showers Using Dielectric-loaded Waveguides
Authors:
P. W. Gorham,
J. Bynes,
B. Fox,
C. Hast,
B. Hill,
K. Jobe,
C. Miki,
R. Prechelt,
B. Rotter,
D. P. Saltzberg,
S. A. Wissel,
G. S. Varner,
S. Zekioglu
Abstract:
We report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of $\sim 10^3-10^4$ GeV were pre-showered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid…
▽ More
We report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of $\sim 10^3-10^4$ GeV were pre-showered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid alumina ($Al_2 O_3$) bars. In the 5-8 GHz $TE_{10}$ single-mode band determined by the presence of the dielectric in the waveguide, we observed band-limited microwave impulses with amplitude proportional to bunch energy. Signals in different waveguide elements measuring the same shower were used to estimate relative time differences with 2.3 picosecond precision. These measurements establish a basis for using arrays of alumina-loaded waveguide elements, with exceptional radiation hardness, as very high precision timing planes for high-energy physics detectors.
△ Less
Submitted 25 April, 2018; v1 submitted 5 August, 2017;
originally announced August 2017.
-
Luminosity measurements for the R scan experiment at BESIII
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
X. C. Ai,
O. Albayrak,
M. Albrecht,
D. J. Ambrose,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai
, et al. (405 additional authors not shown)
Abstract:
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Beijing Spectrometer (BESIII) at the Beijing Electron-Positron Collider (BEPCII), the integrated luminosities have been measur…
▽ More
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Beijing Spectrometer (BESIII) at the Beijing Electron-Positron Collider (BEPCII), the integrated luminosities have been measured at the different c.m. energies, individually. The results are the important inputs for R value and $J/ψ$ resonance parameter measurements.
△ Less
Submitted 11 February, 2017;
originally announced February 2017.
-
Invited Article: miniTimeCube
Authors:
V. A. Li,
R. Dorrill,
M. J. Duvall,
J. Koblanski,
S. Negrashov,
M. Sakai,
S. A. Wipperfurth,
K. Engel,
G. R. Jocher,
J. G. Learned,
L. Macchiarulo,
S. Matsuno,
W. F. McDonough,
H. P. Mumm,
J. Murillo,
K. Nishimura,
M. Rosen,
S. M. Usman,
G. S. Varner
Abstract:
We present the development of the miniTimeCube (mTC), a novel compact neutrino detector. The mTC is a multipurpose detector, aiming to detect not only neutrinos but also fast/thermal neutrons. Potential applications include the counterproliferation of nuclear materials and the investigation of antineutrino short-baseline effects. The mTC is a plastic 0.2% $^{10}$B - doped scintillator (13 cm)$^3$…
▽ More
We present the development of the miniTimeCube (mTC), a novel compact neutrino detector. The mTC is a multipurpose detector, aiming to detect not only neutrinos but also fast/thermal neutrons. Potential applications include the counterproliferation of nuclear materials and the investigation of antineutrino short-baseline effects. The mTC is a plastic 0.2% $^{10}$B - doped scintillator (13 cm)$^3$ cube surrounded by 24 Micro-Channel Plate (MCP) photon detectors, each with an $8\times8$ anode totaling 1536 individual channels/pixels viewing the scintillator. It uses custom-made electronics modules which mount on top of the MCPs, making our detector compact and able to both distinguish different types of events and reject noise in real time. The detector is currently deployed and being tested at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR) nuclear reactor (20 MW$_\mathrm{th}$) in Gaithersburg, MD. A shield for further tests is being constructed, and calibration and upgrades are ongoing. The mTC's improved spatiotemporal resolution will allow for determination of incident particle directions beyond previous capabilities.
△ Less
Submitted 3 February, 2016;
originally announced February 2016.
-
The dual-mirror Small Size Telescope for the Cherenkov Telescope Array
Authors:
G. Pareschi,
G. Agnetta,
L. A. Antonelli,
D. Bastieri,
G. Bellassai,
M. Belluso,
C. Bigongiari,
S. Billotta,
B. Biondo,
G. Bonanno,
G. Bonnoli,
P. Bruno,
A. Bulgarelli,
R. Canestrari,
M. Capalbi,
P. Caraveo,
A. Carosi,
E. Cascone,
O. Catalano,
M. Cereda,
P. Conconi,
V. Conforti,
G. Cusumano,
V. De Caprio,
A. De Luca
, et al. (89 additional authors not shown)
Abstract:
In this paper, the development of the dual mirror Small Size Telescopes (SST) for the Cherenkov Telescope Array (CTA) is reviewed. Up to 70 SST, with a primary mirror diameter of 4 m, will be produced and installed at the CTA southern site. These will allow investigation of the gamma-ray sky at the highest energies accessible to CTA, in the range from about 1 TeV to 300 TeV. The telescope presente…
▽ More
In this paper, the development of the dual mirror Small Size Telescopes (SST) for the Cherenkov Telescope Array (CTA) is reviewed. Up to 70 SST, with a primary mirror diameter of 4 m, will be produced and installed at the CTA southern site. These will allow investigation of the gamma-ray sky at the highest energies accessible to CTA, in the range from about 1 TeV to 300 TeV. The telescope presented in this contribution is characterized by two major innovations: the use of a dual mirror Schwarzschild-Couder configuration and of an innovative camera using as sensors either multi-anode photomultipliers (MAPM) or silicon photomultipliers (SiPM). The reduced plate-scale of the telescope, achieved with the dual-mirror optics, allows the camera to be compact (40 cm in diameter), and low-cost. The camera, which has about 2000 pixels of size 6x6 mm^2, covers a field of view of 10°. The dual mirror telescopes and their cameras are being developed by three consortia, ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana, Italy/INAF), GATE (Gamma-ray Telescope Elements, France/Paris Observ.) and CHEC (Compact High Energy Camera, universities in UK, US and Japan) which are merging their efforts in order to finalize an end-to-end design that will be constructed for CTA. A number of prototype structures and cameras are being developed in order to investigate various alternative designs. In this contribution, these designs are presented, along with the technological solutions under study.
△ Less
Submitted 18 July, 2013;
originally announced July 2013.
-
Measurements of Baryon Pair Decays of $χ_{cJ}$ Mesons
Authors:
M. Ablikim,
M. N. Achasov,
O. Albayrak,
D. J. Ambrose,
F. F. An,
Q. An,
J. Z. Bai,
Y. Ban,
J. Becker,
J. V. Bennett,
M. Bertani,
J. M. Bian,
E. Boger,
O. Bondarenko,
I. Boyko,
R. A. Briere,
V. Bytev,
X. Cai,
O. Cakir,
A. Calcaterra,
G. F. Cao,
S. A. Cetin,
J. F. Chang,
G. Chelkov,
G. Chen
, et al. (326 additional authors not shown)
Abstract:
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$,…
▽ More
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$, $(20.8 \pm 1.6 \pm 2.3)\times 10^{-5}$; $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{0}\barΣ^{0})$ = $(47.8 \pm 3.4 \pm 3.9)\times 10^{-5}$, $(3.8 \pm 1.0 \pm 0.5)\times 10^{-5}$, $(4.0 \pm 1.1 \pm 0.5) \times 10^{-5}$; and $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{+}\barΣ^{-})$ = $(45.4 \pm 4.2 \pm 3.0)\times 10^{-5}$, $(5.4 \pm 1.5 \pm 0.5)\times 10^{-5}$, $(4.9 \pm 1.9 \pm 0.7)\times 10^{-5}$, where the first error is statistical and the second is systematic. Upper limits on the branching fractions for the decays of $χ_{c1,2}\rightarrowΣ^{0}\barΣ^{0}$, $Σ^{+}\barΣ^{-}$, are estimated to be $\cal{B}$$(χ_{c1}\rightarrowΣ^{0}\barΣ^{0}) < 6.2\times 10^{-5}$, $\cal{B}$$(χ_{c2}\rightarrowΣ^{0}\barΣ^{0}) < 6.5\times 10^{-5}$, $\cal{B}$$(χ_{c1}\rightarrowΣ^{+}\barΣ^{-}) < 8.7\times 10^{-5}$ and $\cal{B}$$(χ_{c2}\rightarrowΣ^{+}\barΣ^{-}) < 8.8\times 10^{-5}$ at the 90% confidence level.
△ Less
Submitted 4 March, 2013; v1 submitted 9 November, 2012;
originally announced November 2012.
-
The beam energy measurement system for the Beijing electron-positron collider
Authors:
E. V. Abakumova,
M. N. Achasov,
V. E. Blinov,
X. Cai,
H. Y. Dong,
C. D. Fu,
F. A. Harris,
V. V. Kaminsky,
A. A. Krasnov,
Q. Liu,
X. H. Mo,
N. Yu. Muchnoi,
I. B. Nikolaev,
Q. Qin,
H. M. Qu,
S. L. Olsen,
E. E. Pyata,
A. G. Shamov,
C. P. Shen,
K. Yu. Todyshev,
G. S. Varner,
Y. F. Wang,
Q. Xiao,
J. Q. Xu,
J. Y. Zhang
, et al. (3 additional authors not shown)
Abstract:
The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2 \cdot 10^{-5}. The relative uncertainty of the beam's energy spread is about 6 %.
The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2 \cdot 10^{-5}. The relative uncertainty of the beam's energy spread is about 6 %.
△ Less
Submitted 27 September, 2011;
originally announced September 2011.
-
KEKB Beam Collision Stability at the Picosecond Timing and Micron Position Resolution as observed with the Belle Detector
Authors:
H. Kichimi,
K. Trabelsi,
S. Uehara,
M. Nakao,
K. Akai,
T. Ieiri,
M. Tobiyama,
M. D. Jones,
M. W. Peters,
G. S. Varner,
T. E. Browder
Abstract:
Using the Belle detector we study the characteristics of beam collisions at the KEKB 3.5 GeV $e^+$ on 8 GeV $e^-$ asymmetric energy collider. We investigate the collision timing {\tip} and its $z$-coordinate along the beam axis {\zip} as a function of the position of the colliding bunch in a beam train. The various {\tip} and {\zip} behaviors observed by Belle are attributed to beam loading effe…
▽ More
Using the Belle detector we study the characteristics of beam collisions at the KEKB 3.5 GeV $e^+$ on 8 GeV $e^-$ asymmetric energy collider. We investigate the collision timing {\tip} and its $z$-coordinate along the beam axis {\zip} as a function of the position of the colliding bunch in a beam train. The various {\tip} and {\zip} behaviors observed by Belle are attributed to beam loading effects in the radio frequency cavities that accelerate the beams with a beam abort gap. We report these results in detail and discuss the prospects for the SuperKEKB collider.
△ Less
Submitted 20 March, 2010; v1 submitted 7 January, 2010;
originally announced January 2010.
-
The PRO1 ASIC for Fast Wilkinson Encoding
Authors:
L. L. Ruckman,
G. S. Varner
Abstract:
Wilkinson conversion of stored samples in large Switch Capacitor Array (SCA) ASICs, such as used for high speed waveform sampling, has many benefits in terms of compactness, no missing output codes, low power requirements and robustness. However such Analog-to-Digital conversions are relatively slow, limited by the encoder clock speed. By repeating the same fast sampling technique used by the SC…
▽ More
Wilkinson conversion of stored samples in large Switch Capacitor Array (SCA) ASICs, such as used for high speed waveform sampling, has many benefits in terms of compactness, no missing output codes, low power requirements and robustness. However such Analog-to-Digital conversions are relatively slow, limited by the encoder clock speed. By repeating the same fast sampling technique used by the SCA, combined with a fast priority encoder, significantly faster conversion is demonstrated for a prototype ASIC designated PRO1. For 8-10 bits of resolution, this technique is compact and requires far fewer system resources.
△ Less
Submitted 4 November, 2008; v1 submitted 3 September, 2008;
originally announced September 2008.
-
Sub-10ps Monolithic and Low-power Photodetector Readout
Authors:
Gary S. Varner,
Larry L. Ruckman
Abstract:
Recent advances in photon detectors have resulted in high-density imaging arrays that offer many performance and cost advantages. In particular, the excellent transit time spread of certain devices show promise to provide tangible benefits in applications such as Positron Emission Tomography (PET). Meanwhile, high-density, high-performance readout techniques have not kept on pace for exploiting…
▽ More
Recent advances in photon detectors have resulted in high-density imaging arrays that offer many performance and cost advantages. In particular, the excellent transit time spread of certain devices show promise to provide tangible benefits in applications such as Positron Emission Tomography (PET). Meanwhile, high-density, high-performance readout techniques have not kept on pace for exploiting these developments. Photodetector readout for next generation high event rate particle identification and time-resolved PET requires a highly-integrated, low-power, and cost-effective readout technique. We propose fast waveform sampling as a method that meets these criteria and demonstrate that sub-10ps resolution can be obtained for an existing device.
△ Less
Submitted 15 May, 2008;
originally announced May 2008.
-
BES3 time of flight monitoring system
Authors:
F. A. Harris,
J. W. Kennedy,
Q. Liu,
L. Nguyen,
S. L. Olsen,
M. Rosen,
C. P. Shen,
G. S. Varner,
Y. K. Heng,
Z. J. Sun,
K. J. Zhu,
Q. An,
C. Q. Feng,
S. B. Liu
Abstract:
A Time of Flight monitoring system has been developed for BES3.
The light source is a 442-443 nm laser diode, which is stable and provides a pulse width as narrow as 50 ps and a peak power as large as 2.6 W. Two optical-fiber bundles with a total of 512 optical fibers, including spares, are used to distribute the light pulses to the Time of Flight counters. The design, operation, and performan…
▽ More
A Time of Flight monitoring system has been developed for BES3.
The light source is a 442-443 nm laser diode, which is stable and provides a pulse width as narrow as 50 ps and a peak power as large as 2.6 W. Two optical-fiber bundles with a total of 512 optical fibers, including spares, are used to distribute the light pulses to the Time of Flight counters. The design, operation, and performance of the system are described.
△ Less
Submitted 26 April, 2008;
originally announced April 2008.
-
The first version Buffered Large Analog Bandwidth (BLAB1) ASIC for high luminosity collider and extensive radio neutrino detectors
Authors:
Gary S. Varner,
Larry L. Ruckman,
Andrew Wong
Abstract:
Future detectors for high luminosity particle identification and ultra high energy neutrino observation would benefit from a digitizer capable of recording sensor elements with high analog bandwidth and large record depth, in a cost-effective, compact and low-power way. A first version of the Buffered Large Analog Bandwidth (BLAB1) ASIC has been designed based upon the lessons learned from the d…
▽ More
Future detectors for high luminosity particle identification and ultra high energy neutrino observation would benefit from a digitizer capable of recording sensor elements with high analog bandwidth and large record depth, in a cost-effective, compact and low-power way. A first version of the Buffered Large Analog Bandwidth (BLAB1) ASIC has been designed based upon the lessons learned from the development of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) ASIC. While this LABRADOR ASIC has been very successful and forms the basis of a generation of new, large-scale radio neutrino detectors, its limited sampling depth is a major drawback. A prototype has been designed and fabricated with 65k deep sampling at multi-GSa/s operation. We present test results and directions for future evolution of this sampling technique.
△ Less
Submitted 4 May, 2008; v1 submitted 15 February, 2008;
originally announced February 2008.
-
A Monolithic Time Stretcher for Precision Time Recording
Authors:
Gary S. Varner,
Larry L. Ruckman
Abstract:
Identifying light mesons which contain only up/down quarks (pions) from those containing a strange quark (kaons) over the typical meter length scales of a particle physics detector requires instrumentation capable of measuring flight times with a resolution on the order of 20ps. In the last few years a large number of inexpensive, multi-channel Time-to-Digital Converter (TDC) chips have become a…
▽ More
Identifying light mesons which contain only up/down quarks (pions) from those containing a strange quark (kaons) over the typical meter length scales of a particle physics detector requires instrumentation capable of measuring flight times with a resolution on the order of 20ps. In the last few years a large number of inexpensive, multi-channel Time-to-Digital Converter (TDC) chips have become available. These devices typically have timing resolution performance in the hundreds of ps regime. A technique is presented that is a monolithic version of ``time stretcher'' solution adopted for the Belle Time-Of-Flight system to address this gap between resolution need and intrinsic multi-hit TDC performance.
△ Less
Submitted 6 April, 2007; v1 submitted 23 January, 2007;
originally announced January 2007.
-
Observations of the Askaryan Effect in Ice
Authors:
ANITA collaboration,
P. W. Gorham,
S. W. Barwick,
J. J. Beatty,
D. Z. Besson,
W. R. Binns,
C. Chen,
P. Chen,
J. M. Clem,
A. Connolly,
P. F. Dowkontt,
M. A. DuVernois,
R. C. Field,
D. Goldstein,
A. Goodhue,
C. Hast,
C. L. Hebert,
S. Hoover,
M. H. Israel,
J. Kowalski,
J. G. Learned,
K. M. Liewer,
J. T. Link,
E. Lusczek,
S. Matsuno
, et al. (16 additional authors not shown)
Abstract:
We report on the first observations of the Askaryan effect in ice: coherent impulsive radio Cherenkov radiation from the charge asymmetry in an electromagnetic (EM) shower. Such radiation has been observed in silica sand and rock salt, but this is the first direct observation from an EM shower in ice. These measurements are important since the majority of experiments to date that rely on the eff…
▽ More
We report on the first observations of the Askaryan effect in ice: coherent impulsive radio Cherenkov radiation from the charge asymmetry in an electromagnetic (EM) shower. Such radiation has been observed in silica sand and rock salt, but this is the first direct observation from an EM shower in ice. These measurements are important since the majority of experiments to date that rely on the effect for ultra-high energy neutrino detection are being performed using ice as the target medium. As part of the complete validation process for the Antarctic Impulsive Transient Antenna (ANITA) experiment, we performed an experiment at the Stanford Linear Accelerator Center (SLAC) in June 2006 using a 7.5 metric ton ice target, yielding results fully consistent with theoretical expectations.
△ Less
Submitted 11 January, 2007; v1 submitted 3 November, 2006;
originally announced November 2006.
-
The Modern FPGA as Discriminator, TDC and ADC
Authors:
Gary S. Varner
Abstract:
Recent generations of Field Programmable Gate Arrays (FPGAs) have become indispensible tools for complex state machine control and signal processing, and now routinely incorporate CPU cores to allow execution of user software code. At the same time, their exceptional performance permits low-power implementation of functionality previously the exclusive domain of dedicated analog electronics. Spe…
▽ More
Recent generations of Field Programmable Gate Arrays (FPGAs) have become indispensible tools for complex state machine control and signal processing, and now routinely incorporate CPU cores to allow execution of user software code. At the same time, their exceptional performance permits low-power implementation of functionality previously the exclusive domain of dedicated analog electronics. Specific examples presented here use FPGAs as discriminator, time-to-digital (TDC) and analog-to-digital converter (ADC). All three cases are examples of instrumentation for current or future astroparticle experiments.
△ Less
Submitted 24 June, 2006; v1 submitted 13 May, 2006;
originally announced May 2006.
-
The Large Analog Bandwidth Recorder And Digitizer with Ordered Readout (LABRADOR) ASIC
Authors:
G. S. Varner,
L. L. Ruckman,
J. W. Nam,
R. J. Nichol,
J. Cao,
P. W. Gorham,
M. Wilcox
Abstract:
Three generations of full-custom analog integrated circuits designed for low-power, high-speed sampling of Radio-Frequency (RF) transients in excess of the Nyquist minimum have been developed. These 0.25$μm$ CMOS devices are denoted the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) ASICs and finally consist of 9 channels of 260 deep sampling. Continuous sampling i…
▽ More
Three generations of full-custom analog integrated circuits designed for low-power, high-speed sampling of Radio-Frequency (RF) transients in excess of the Nyquist minimum have been developed. These 0.25$μm$ CMOS devices are denoted the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) ASICs and finally consist of 9 channels of 260 deep sampling. Continuous sampling is provided with common stop capability. Input analog bandwidth is approximately 1GHz and sampling speeds are adjustable from 0.02 to 3.7GSa/s. Completely parallel internal conversion supports 12-bit digitization and readout of all 2340 cells in under 50$μs$.
△ Less
Submitted 14 June, 2007; v1 submitted 2 September, 2005;
originally announced September 2005.
-
Evaluation of Giga-bit Ethernet Instrumentation for SalSA Electronics Readout (GEISER)
Authors:
Gary S. Varner,
Laine Murakami,
David Ridley,
Chaopin Zhu,
Peter Gorham
Abstract:
An instrumentation prototype for acquiring high-speed transient data from an array of high bandwidth antennas is presented. Multi-kilometer cable runs complicate acquisition of such large bandwidth radio signals from an extensive antenna array. Solutions using analog fiber optic links are being explored, though are very expensive. We propose an inexpensive solution that allows for individual ope…
▽ More
An instrumentation prototype for acquiring high-speed transient data from an array of high bandwidth antennas is presented. Multi-kilometer cable runs complicate acquisition of such large bandwidth radio signals from an extensive antenna array. Solutions using analog fiber optic links are being explored, though are very expensive. We propose an inexpensive solution that allows for individual operation of each antenna element, operating at potentially high local self-trigger rates. Digitized data packets are transmitted to the surface via commercially available Giga-bit Ethernet hardware. Events are then reconstructed on a computer farm by sorting the received packets using standard networking gear, eliminating the need for custom, very high-speed trigger hardware. Such a system is completely scalable and leverages the hugh capital investment made by the telecommunications industry. Test results from a demonstration prototype are presented.
△ Less
Submitted 1 July, 2005;
originally announced July 2005.
-
A Scintillating Fiber Hodoscope for a Bremstrahlung Luminosity Monitor at an Electron$-$Positron Collider
Authors:
D. H. Brown,
D. H. Orlov,
G. S. Varner,
W. A. Worstell,
S. I. Redin
Abstract:
The performance of a scintillating fiber (2mm diameter) position sensitive detector ($4.8 \times 4.8$ cm$^2$ active area) for the single bremstrahlung luminosity monitor at the VEPP-2M electron-positron collider in Novosibirsk, Russia is described. Custom electronics is triggered by coincident hits in the X and Y planes of 24 fibers each, and reduces 64 PMT signals to a 10 bit (X,Y) address. Hit…
▽ More
The performance of a scintillating fiber (2mm diameter) position sensitive detector ($4.8 \times 4.8$ cm$^2$ active area) for the single bremstrahlung luminosity monitor at the VEPP-2M electron-positron collider in Novosibirsk, Russia is described. Custom electronics is triggered by coincident hits in the X and Y planes of 24 fibers each, and reduces 64 PMT signals to a 10 bit (X,Y) address. Hits are accumulated (10 kHz) in memory and display (few Hz) the VEPP-2M collision vertex. Fitting the strongly peaked distribution ( $\sim$ 3-4 mm at 1.6m from the collision vertex of VEPP-2M ) to the expected QED angular distribution yields a background in agreement with an independent determination of the VEPP-2M luminosity.
△ Less
Submitted 15 July, 1996;
originally announced July 1996.