Design and Implementation of a Low-Power Low-Noise Biopotential Amplifier in 28 nm CMOS Technology with a Compact Die-Area of 2500 $μ$m$^2$
Authors:
Esmaeil Ranjbar Koleibi,
Konin Koua,
William Lemaire,
Maher Benhouria,
Marwan Besrour,
Takwa Omrani,
Jérémy Ménard,
Louis-Philippe Gauthier,
Montassar Dridi,
Mahziar Serri Mazandarani,
Benoit Gosselin,
Sébastien Royand Réjean Fontaine
Abstract:
This paper presents a compact low-power, low-noise bioamplifier for multi-channel electrode arrays, aimed at recording action potentials. The design we put forth attains a notable decrease in both size and power consumption. This is achieved by incorporating an active lowpass filter that doesn't rely on bulky DC-blocking capacitors, and by utilizing the TSMC 28 nm HPC CMOS technology. This paper p…
▽ More
This paper presents a compact low-power, low-noise bioamplifier for multi-channel electrode arrays, aimed at recording action potentials. The design we put forth attains a notable decrease in both size and power consumption. This is achieved by incorporating an active lowpass filter that doesn't rely on bulky DC-blocking capacitors, and by utilizing the TSMC 28 nm HPC CMOS technology. This paper presents extensive simulation results of noise and results from measured performance. With a mid-band gain of 58 dB, a -3 dB bandwidth of 7 kHz (from 150 Hz to 7.1 kHz), and an input-referred noise of 15.8 $μ$V$_{\rm rms}$ corresponding to a NEF of 12. The implemented design achieves a favourable trade-off between noise, area, and power consumption, surpassing previous findings in terms of size and power. The amplifier occupies the smallest area of 2500 $μ$m$^2$ and consumes only 3.4 $μ$W from a 1.2 V power supply corresponding to a power efficiency factor of 175 and an area efficiency factor of 0.43, respectively.
△ Less
Submitted 9 January, 2024;
originally announced June 2024.
Feasibility Assessment of an Optically Powered Digital Retinal Prosthesis Architecture for Retinal Ganglion Cell Stimulation
Authors:
William Lemaire,
Maher Benhouria,
Konin Koua,
Wei Tong,
Gabriel Martin-Hardy,
Melanie Stamp,
Kumaravelu Ganesan,
Louis-Philippe Gauthier,
Marwan Besrour,
Arman Ahnood,
David John Garrett,
Sébastien Roy,
Michael Ibbotson,
Steven Prawer,
Réjean Fontaine
Abstract:
Clinical trials previously demonstrated the notable capacity to elicit visual percepts in blind patients affected with retinal diseases by electrically stimulating the remaining neurons on the retina. However, these implants restored very limited visual acuity and required transcutaneous cables traversing the eyeball, leading to reduced reliability and complex surgery with high postoperative infec…
▽ More
Clinical trials previously demonstrated the notable capacity to elicit visual percepts in blind patients affected with retinal diseases by electrically stimulating the remaining neurons on the retina. However, these implants restored very limited visual acuity and required transcutaneous cables traversing the eyeball, leading to reduced reliability and complex surgery with high postoperative infection risks. To overcome the limitations imposed by cables, a retinal implant architecture in which near-infrared illumination carries both power and data through the pupil to a digital stimulation controller is presented. A high efficiency multi-junction photovoltaic cell transduces the optical power to a CMOS stimulator capable of delivering flexible interleaved sequential stimulation through a diamond microelectrode array. To demonstrate the capacity to elicit a neural response with this approach while complying with the optical irradiance limit at the pupil, fluorescence imaging with a calcium indicator is used on a degenerate rat retina. The power delivered by the laser at the permissible irradiance of 4 mW/mm2 at 850 nm is shown to be sufficient to both power the stimulator ASIC and elicit a response in retinal ganglion cells (RGCs), with the ability to generate of up to 35 000 pulses per second at the average stimulation threshold. This confirms the feasibility of generating a response in RGCs with an infrared-powered digital architecture capable of delivering complex sequential stimulation patterns at high repetition rates, albeit with some limitations.
△ Less
Submitted 13 October, 2023; v1 submitted 23 October, 2020;
originally announced October 2020.