Noncovalent force spectroscopy using wide-field optical and diamond-based magnetic imaging
Authors:
Sean Lourette,
Lykourgos Bougas,
Metin Kayci,
Shoujun Xu,
Dmitry Budker
Abstract:
A realization of the force-induced remnant magnetization spectroscopy (FIRMS) technique of specific biomolecular binding is presented where detection is accomplished with wide-field optical and diamond-based magnetometry using an ensemble of nitrogen-vacancy (NV) color centers. The technique may be adapted for massively parallel screening of arrays of nanoscale samples.
A realization of the force-induced remnant magnetization spectroscopy (FIRMS) technique of specific biomolecular binding is presented where detection is accomplished with wide-field optical and diamond-based magnetometry using an ensemble of nitrogen-vacancy (NV) color centers. The technique may be adapted for massively parallel screening of arrays of nanoscale samples.
△ Less
Submitted 27 August, 2019;
originally announced August 2019.
-
Infrared laser magnetometry with a NV doped diamond intracavity etalon
Authors:
Yannick Dumeige,
Jean-François Roch,
Fabien Bretenaker,
Thierry Debuisschert,
Victor Acosta,
Christoph Becher,
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Alexander Wilzewski,
Dmitry Budker
Abstract:
We propose an hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magne…
▽ More
We propose an hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magnetometer that can be operated at room-temperature. The sensitivity to the magnetic field limited by the photon shot-noise of the output laser beam is estimated to be around $250~\mathrm{fT/\sqrt{Hz}}$. Unlike usual NV center infrared magnetometry, this method would not require an external frequency stabilized laser. Since the proposed system relies on the competition between the laser threshold and an intracavity absorption, such laser-based optical sensor could be easily adapted to a broad variety of physical systems.
△ Less
Submitted 18 October, 2018;
originally announced October 2018.
-
Eddy-current imaging with nitrogen-vacancy centers in diamond
Authors:
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Huijie Zheng,
Oleg Tretiak,
Yu Yang,
Dmitry Budker
Abstract:
We demonstrate microwave-free eddy-current imaging using nitrogen-vacancy centers in diamond. By detecting the eddy-current induced magnetic field of conductive samples, we can distinguish between different materials and shapes and identify structural defects. Our technique allows for the discrimination of different materials according to their conductivity. The sensitivity of the measurements is…
▽ More
We demonstrate microwave-free eddy-current imaging using nitrogen-vacancy centers in diamond. By detecting the eddy-current induced magnetic field of conductive samples, we can distinguish between different materials and shapes and identify structural defects. Our technique allows for the discrimination of different materials according to their conductivity. The sensitivity of the measurements is calculated as 8$\times 10 ^{5}$\,S/m\,$\sqrt[]{\textrm{Hz}}$ at 3.5\,MHz, for a cylindrical sample with radius $r_0$\,=\,1\,mm and height $h$\,=\,0.1\,mm (volume $\sim$\,0.3\,mm$^3$), at a distance of 0.5\,mm. In comparison with existing technologies, the diamond-based device exhibits a superior bandwidth and spatial resolution. In particular, we demonstrate a flat frequency response from DC to 3.5 MHz and a spatial resolution of 348\,$\pm$\,2\,$μ$m.
△ Less
Submitted 5 October, 2018;
originally announced October 2018.
-
Sawtooth wave adiabatic passage slowing of dysprosium
Authors:
Niels Petersen,
Florian Mühlbauer,
Lykourgos Bougas,
Arijit Sharma,
Dmitry Budker,
Patrick Windpassinger
Abstract:
We report on sawtooth wave adiabatic passage (SWAP) slowing of bosonic and fermionic dysprosium isotopes by using a 136 kHz wide transition at 626 nm. A beam of precooled atoms is further decelerated in one dimension by the SWAP force and the amount of atoms at near zero velocity is measured. We demonstrate that the SWAP slowing can be twice as fast as in a conventional optical molasses operated o…
▽ More
We report on sawtooth wave adiabatic passage (SWAP) slowing of bosonic and fermionic dysprosium isotopes by using a 136 kHz wide transition at 626 nm. A beam of precooled atoms is further decelerated in one dimension by the SWAP force and the amount of atoms at near zero velocity is measured. We demonstrate that the SWAP slowing can be twice as fast as in a conventional optical molasses operated on the same transition. In addition, we investigate the parameter range for which the SWAP force is efficiently usable in our set-up, and relate the results to the adiabaticity condition. Furthermore, we add losses to the hyperfine ground-state population of fermionic dysprosium during deceleration and observe more robust slowing with SWAP compared to slowing with the radiation pressure force.
△ Less
Submitted 17 September, 2018;
originally announced September 2018.
-
Miniature cavity-enhanced diamond magnetometer
Authors:
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Nathan Leefer,
Teng Wu,
Kasper Jensen,
Yannick Dumeige,
Dmitry Budker
Abstract:
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/…
▽ More
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/$\sqrt{\rm{Hz}}$, a projected photon shot-noise-limited sensitivity of 22 pT/$\sqrt{\rm{Hz}}$ and an estimated quantum projection-noise-limited sensitivity of 0.43 pT/$\sqrt{\rm{Hz}}$ with the sensing volume of $\sim$ 390 $μ$m $\times$ 4500 $μ$m$^{2}$. The presented miniaturized device is the basis for an endoscopic magnetic field sensor for biomedical applications.
△ Less
Submitted 7 June, 2017;
originally announced June 2017.
-
Level anti-crossing magnetometry with color centers in diamond
Authors:
Huijie Zheng,
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Reinis Lazda,
Andris Berzins,
Florian Helmuth Gahbauer,
Marcis Auzinsh,
Ruvin Ferber,
Dmitry Budker
Abstract:
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background…
▽ More
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background MF of 102.4\,mT. Following the first approach, we investigate the feature parameters for precise alignment in a dilute diamond sample; the second approach extends the sensing protocol into absorption via detection of the GSLAC in the diamond transmission of a 1042\,nm laser beam. This leads to an increase of GSLAC contrast and results in a magnetometer with a sensitivity of 0.45\,nT/$\sqrt{\text{Hz}}$ and a photon shot-noise limited sensitivity of 12.2 pT/$\sqrt{\rm{Hz}}$.
△ Less
Submitted 24 January, 2017;
originally announced January 2017.
-
Solution nuclear magnetic resonance spectroscopy on a nanostructured diamond chip
Authors:
P. Kehayias,
A. Jarmola,
N. Mosavian,
I. Fescenko,
F. M. Benito,
A. Laraoui,
J. Smits,
L. Bougas,
D. Budker,
A. Neumann,
S. R. J. Brueck,
V. M. Acosta
Abstract:
We demonstrate nuclear magnetic resonance (NMR) spectroscopy of picoliter-volume solutions with a nanostructured diamond chip. Using optical interferometric lithography, diamond surfaces were nanostructured with dense, high-aspect-ratio nanogratings, enhancing the surface area by more than a factor of 15 over mm^2 regions of the chip. The nanograting sidewalls were doped with nitrogen-vacancy (NV)…
▽ More
We demonstrate nuclear magnetic resonance (NMR) spectroscopy of picoliter-volume solutions with a nanostructured diamond chip. Using optical interferometric lithography, diamond surfaces were nanostructured with dense, high-aspect-ratio nanogratings, enhancing the surface area by more than a factor of 15 over mm^2 regions of the chip. The nanograting sidewalls were doped with nitrogen-vacancy (NV) centers so that more than 10 million NV centers in a (25 micrometer)^2 laser spot are located close enough to the diamond surface (5 nm) to detect the NMR spectrum of 1 pL of fluid lying within adjacent nanograting grooves. The platform was used to perform 1H and 19F NMR spectroscopy at room temperature in magnetic fields below 50 mT. Using a solution of CsF in glycerol, we demonstrate that 4 +/- 2 x 10^12 19F spins in a 1 pL volume, can be detected with a signal-to-noise ratio of 3 in 1 s integration. This represents nearly two orders of magnitude improvement in concentration sensitivity over previous NV and picoliter NMR studies.
△ Less
Submitted 5 January, 2017;
originally announced January 2017.