Abstract
The placenta plays a key contribution to successful pregnancy outcome. New MR imaging techniques are able to reveal intricate details about placental structure and function and measure placental blood flow and feto-placental oxygenation. Placental diffusion-weighted MRI is however challenging due to maternal breathing motion and poor signal-to-noise ratio making motion correction important for subsequent quantitative analysis. In this work, we (i) introduce an iterative model-based registration technique which incorporates a placenta-specific model into the motion correction process and (ii) describe a new technique making use of a Bayesian shrinkage prior to obtain robust estimates of individual and population trends in parameters. Our results suggest that the proposed registration method improves alignment of placental data and that the Bayesian fitting technique allows the estimation of voxel-level placenta flow parameters and the population trend in each parameter with gestational age (GA). We report gestational age dependent differences in vascular compartments and fetal oxygen saturation values observed across 9 normally grown pregnancies between 25–34 weeks gestational age and show qualitatively improved parameter mapping and more precise longitudinal fitting. Fetal oxygen saturation (\(\mathrm {FO_2}\)) is observed to decrease at \(\mathrm {FO_2}=-3.6(\mathrm {GA_{weeks}})+190.2(\%)\). This technique provides a robust framework for analysing longitudinal changes in both normal and pathological placental function.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Flouri, D., Lesnic, D., Sourbron, S.P.: Fitting the two-compartment model in DCE-MRI by linear inversion. Magn. Reson. Med. 76(3), 998–1006 (2016)
Jerome, N.P., et al.: Extended T2-IVIM model for correction of TE dependence of pseudo-diffusion volume fraction in clinical diffusion-weighted magnetic resonance imaging. Phys. Med. Biol. 61(24), N667 (2016)
Lawn, J.E., et al.: Stillbirths: Where? When? Why? How to make the data count? Lancet 377(9775), 1448–1463 (2011)
Melbourne, A., et al.: Separating fetal and maternal placenta circulations using multiparametric MRI. Magn. Reson. Med. 81(1), 350–361 (2018)
Modat, M., et al.: Fast free-form deformation using graphics processing units. Comput. Methods Programs Biomed. 98(3), 278–284 (2010)
Orton, M.R., Collins, D.J., Koh, D., Leach, M.O.: Improved intravoxel incoherent motion analysis of diffusion weighted imaging by data driven Bayesian modeling. Magn. Reson. Med. 71(1), 411–420 (2014)
Siauve, N., et al.: Assessment of human placental perfusion by intravoxel incoherent motion MR imaging. J. Matern Fetal Neonatal Med. 32(2), 293–300 (2019). PMID: 28974131
Acknowledgements
We acknowledge the Wellcome Trust (210182/Z/18/Z, 101957/Z/13/Z), the National Institute for Health Research (NIHR), the EPSRC (NS/A000027/1) and the Radiological Research Trust. We would like to thank our patient and public advisory group for their time and input.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Flouri, D. et al. (2019). Improved Placental Parameter Estimation Using Data-Driven Bayesian Modelling. In: Shen, D., et al. Medical Image Computing and Computer Assisted Intervention – MICCAI 2019. MICCAI 2019. Lecture Notes in Computer Science(), vol 11766. Springer, Cham. https://doi.org/10.1007/978-3-030-32248-9_68
Download citation
DOI: https://doi.org/10.1007/978-3-030-32248-9_68
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-32247-2
Online ISBN: 978-3-030-32248-9
eBook Packages: Computer ScienceComputer Science (R0)