Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Improved Placental Parameter Estimation Using Data-Driven Bayesian Modelling

  • Conference paper
  • First Online:
Medical Image Computing and Computer Assisted Intervention – MICCAI 2019 (MICCAI 2019)

Abstract

The placenta plays a key contribution to successful pregnancy outcome. New MR imaging techniques are able to reveal intricate details about placental structure and function and measure placental blood flow and feto-placental oxygenation. Placental diffusion-weighted MRI is however challenging due to maternal breathing motion and poor signal-to-noise ratio making motion correction important for subsequent quantitative analysis. In this work, we (i) introduce an iterative model-based registration technique which incorporates a placenta-specific model into the motion correction process and (ii) describe a new technique making use of a Bayesian shrinkage prior to obtain robust estimates of individual and population trends in parameters. Our results suggest that the proposed registration method improves alignment of placental data and that the Bayesian fitting technique allows the estimation of voxel-level placenta flow parameters and the population trend in each parameter with gestational age (GA). We report gestational age dependent differences in vascular compartments and fetal oxygen saturation values observed across 9 normally grown pregnancies between 25–34 weeks gestational age and show qualitatively improved parameter mapping and more precise longitudinal fitting. Fetal oxygen saturation (\(\mathrm {FO_2}\)) is observed to decrease at \(\mathrm {FO_2}=-3.6(\mathrm {GA_{weeks}})+190.2(\%)\). This technique provides a robust framework for analysing longitudinal changes in both normal and pathological placental function.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Flouri, D., Lesnic, D., Sourbron, S.P.: Fitting the two-compartment model in DCE-MRI by linear inversion. Magn. Reson. Med. 76(3), 998–1006 (2016)

    Article  Google Scholar 

  2. Jerome, N.P., et al.: Extended T2-IVIM model for correction of TE dependence of pseudo-diffusion volume fraction in clinical diffusion-weighted magnetic resonance imaging. Phys. Med. Biol. 61(24), N667 (2016)

    Article  Google Scholar 

  3. Lawn, J.E., et al.: Stillbirths: Where? When? Why? How to make the data count? Lancet 377(9775), 1448–1463 (2011)

    Article  Google Scholar 

  4. Melbourne, A., et al.: Separating fetal and maternal placenta circulations using multiparametric MRI. Magn. Reson. Med. 81(1), 350–361 (2018)

    Article  Google Scholar 

  5. Modat, M., et al.: Fast free-form deformation using graphics processing units. Comput. Methods Programs Biomed. 98(3), 278–284 (2010)

    Article  Google Scholar 

  6. Orton, M.R., Collins, D.J., Koh, D., Leach, M.O.: Improved intravoxel incoherent motion analysis of diffusion weighted imaging by data driven Bayesian modeling. Magn. Reson. Med. 71(1), 411–420 (2014)

    Article  Google Scholar 

  7. Siauve, N., et al.: Assessment of human placental perfusion by intravoxel incoherent motion MR imaging. J. Matern Fetal Neonatal Med. 32(2), 293–300 (2019). PMID: 28974131

    Article  Google Scholar 

Download references

Acknowledgements

We acknowledge the Wellcome Trust (210182/Z/18/Z, 101957/Z/13/Z), the National Institute for Health Research (NIHR), the EPSRC (NS/A000027/1) and the Radiological Research Trust. We would like to thank our patient and public advisory group for their time and input.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dimitra Flouri .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Flouri, D. et al. (2019). Improved Placental Parameter Estimation Using Data-Driven Bayesian Modelling. In: Shen, D., et al. Medical Image Computing and Computer Assisted Intervention – MICCAI 2019. MICCAI 2019. Lecture Notes in Computer Science(), vol 11766. Springer, Cham. https://doi.org/10.1007/978-3-030-32248-9_68

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-32248-9_68

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-32247-2

  • Online ISBN: 978-3-030-32248-9

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics