Abstract
Software development is frequently challenged with quality concerns. One of the primary reasons for such issues is the very nature of the software development process. First, it can be difficult to accurately and completely identify the requirements for a software development product. Also, the implementation on various platforms and the need to integrate with sometimes unforeseeable additional systems adds complexity. For safety critical domains, such as the medical device and healthcare sectors, these hurdles are amplified. Whereas a failure in a desktop application may be resolved through a restart with no harm incurred, a failure in a medical device can have life threatening consequences. Our work in the Regulated Software Research Centre (RSRC) aims to support medical device producers in the production of safer medical device software. In this paper, we describe the MDevSPICE framework and how it addresses the safety concerns faced by medical device producers.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
FDA. FDA News on Software Failures Responsible for 24% of all Medical Device Recalls (2012), http://www.fdanews.com/newsletter/article?articleId=147391&issueId=15890 (cited April 12, 2013)
European Commission, Directive 93/42/EEC of the European Parliament and of the Council concerning medical devices, in OJ o L 247 of 2007-09-21. 1993: European Commission, Brussels, Belgium
FDA. Chapter I - Food and drug administration, department of health and human services subchapter H - Medical devices, Part 820 - Quality system regulation, http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/CFRSearch.cfm?CFRPart=820 (cited May 15, 2013)
European Commission, Council directive 90/385/EEC on active implantable medical devices (AIMDD). 1990: Brussels, Belgium
European Commission, Directive 98/79/EC of the European parliament and of the council of 27 October 1998 on in vitro diagnostic medical devices. 1998: Brussels, Belgium
European Commission, Directive 2007/47/EC of the European Parliament and of the Council concerning medical devices, in OJ no L 247 of 2007-09-21. 2007, EC: Brussels, Belgium
ISO, ISO 13485: Medical Devices - Quality Management Systems - Requirements for Regulatory Purposes. 2003, ISO: Geneva, Switzerland
ISO, ISO 9001:2000 - Quality Management Systems - Requirements, Geneva, Switzerland (2000)
IEC, IEC 62304: Medical Device Software - Software Life-Cycle Processes. 2006, IEC: Geneva, Switzerland
IEC, IEC TR 80002-3:2014: Medical device software – Part 3: Process reference model of medical device software life cycle processes (IEC 62304)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Clarke, P., Lepmets, M., McCaffery, F., Finnegan, A., Dorling, A., Flood, D. (2014). MDevSPICE - A Comprehensive Solution for Manufacturers and Assessors of Safety-Critical Medical Device Software. In: Mitasiunas, A., Rout, T., O’Connor, R.V., Dorling, A. (eds) Software Process Improvement and Capability Determination. SPICE 2014. Communications in Computer and Information Science, vol 477. Springer, Cham. https://doi.org/10.1007/978-3-319-13036-1_26
Download citation
DOI: https://doi.org/10.1007/978-3-319-13036-1_26
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-13035-4
Online ISBN: 978-3-319-13036-1
eBook Packages: Computer ScienceComputer Science (R0)