Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

A Study to Investigate Different EEG Reference Choices in Diagnosing Major Depressive Disorder

  • Conference paper
  • First Online:
Neural Information Processing (ICONIP 2015)

Part of the book series: Lecture Notes in Computer Science ((LNTCS,volume 9492))

Included in the following conference series:

Abstract

Choice of an electroencephalogram (EEG) reference is a critical issue during measurement of brain activity. An appropriate reference may improve efficiency during diagnosis of psychiatric conditions, e.g., major depressive disorder (MDD). In literature, various EEG references have been proposed, however, none of them is considered as gold-standard [1]. Therefore, this study aims to evaluate 3 EEG references including infinity reference (IR), average reference (AR) and link-ear (LE) reference based on EEG data acquired from 2 groups: the MDD patients and healthy subjects as controls. The experimental EEG data acquisition involved 2 physiological conditions: eyes closed (EC) and eyes open (EO). Originally, the data were recorded with LE reference and re-referenced to AR and IR. EEG features such as the inter-hemispheric coherences, inter-hemispheric asymmetries, and different frequency bands powers were computed. These EEG features were used as input data to train and test the logistic regression (LR) classifier and the linear kernel support vector machine (SVM). Finally, the results were presented as classification accuracies, sensitivities, and specificities while discriminating the MDD patients from a potential population of healthy controls. According to the results, AR has provided the maximum classification efficiencies for coherence and power based features. The case of asymmetry, IR and LE performed better than AR. The study concluded that the reference selection should include factors such as underlying EEG data, computed features and type of assessment performed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Nunez, P.L.: REST: A good idea but not the gold standard. Clin. Neurophysiol. Official J. Int. Fed. Clin. Neurophysiol. 121(12), 2177 (2010)

    Article  Google Scholar 

  2. Geselowitz, D.B.: The zero of potential. IEEE Eng. Me. Biol. Mag. Q. Mag. Eng. Med. Biol. Soc. 17(1), 128–132 (1997)

    Article  Google Scholar 

  3. Nunez, P.L., et al.: EEG coherency: I: statistics, reference electrode, volume conduction, Laplacians, cortical imaging, and interpretation at multiple scales. Electroencephalogr. Clin. Neurophysiol. 103(5), 499–515 (1997)

    Article  Google Scholar 

  4. Yao, D.: A method to standardize a reference of scalp EEG recordings to a point at infinity. Physiol. Meas. 22(4), 693 (2001)

    Article  Google Scholar 

  5. Zhai, Y., Yao, D.: A study on the reference electrode standardization technique for a realistic head model. Comput. Methods Programs Biomed. 76(3), 229–238 (2004)

    Article  Google Scholar 

  6. Bertrand, O., Perrin, F., Pernier, J.: A theoretical justification of the average reference in topographic evoked potential studies. Electroencephalogr. Clin. Neurophysiol./Evoked Potentials Section 62(6), 462–464 (1985)

    Article  Google Scholar 

  7. Junghöfer, M., et al.: The polar average reference effect: a bias in estimating the head surface integral in EEG recording. Clin. Neurophysiol. 110(6), 1149–1155 (1999)

    Article  Google Scholar 

  8. Yao, D., et al.: A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference. Physiol. Meas. 26(3), 173 (2005)

    Article  Google Scholar 

  9. Xu, P., et al.: Recognizing mild cognitive impairment based on network connectivity analysis of resting EEG with zero reference. Physiol. Meas. 35(7), 1279 (2014)

    Article  Google Scholar 

  10. Fried, S.J., Smith, D.M., Legatt, A.D.: Median nerve somatosensory evoked potential monitoring during carotid endarterectomy: does reference choice matter? J. Clin. Neurophysiol. 31(1), 55–57 (2014)

    Article  Google Scholar 

  11. Mumtaz, W., et al.: Review on EEG and ERP predictive biomarkers for major depressive disorder. Biomed. Signal Process. Control 22, 85–98 (2015)

    Article  Google Scholar 

  12. Hinrikus, H., et al.: Electroencephalographic spectral asymmetry index for detection of depression. Med. Biol. Eng. Compu. 47(12), 1291–1299 (2009)

    Article  Google Scholar 

  13. Association, A.P.: Diagnostic and statistical manual of mental disorders: DSM-IV-TR®. 2000: American Psychiatric Pub

    Google Scholar 

  14. Berg, P., Scherg, M.: Dipole modelling of eye activity and its application to the removal of eye artefacts from the EEG and MEG. Clin. Phys. Physiol. Meas. 12(A), 49 (1991)

    Article  Google Scholar 

  15. Hoechstetter, K., Berg, P., Scherg, M.: BESA research tutorial 4: Distributed source imaging. BESA Research Tutorial, 1–29 (2010)

    Google Scholar 

  16. Hosmer Jr., D.W., Lemeshow, S.: Applied logistic regression. John Wiley & Sons, New York (2004)

    MATH  Google Scholar 

Download references

Acknowledgement

This research is supported by the HiCoE grant for CISIR (0153CA-005), Ministry of Education (MOE), Malaysia, and NSTIP strategic technologies programs, grant number (12-INF2582-02), in the Kingdom of Saudi Arabia.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aamir Saeed Malik .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Mumtaz, W., Malik, A.S., Ali, S.S.A., Yasin, M.A.M. (2015). A Study to Investigate Different EEG Reference Choices in Diagnosing Major Depressive Disorder. In: Arik, S., Huang, T., Lai, W., Liu, Q. (eds) Neural Information Processing. ICONIP 2015. Lecture Notes in Computer Science(), vol 9492. Springer, Cham. https://doi.org/10.1007/978-3-319-26561-2_10

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-26561-2_10

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-26560-5

  • Online ISBN: 978-3-319-26561-2

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics