Abstract
The paper presents results of physicochemical properties of TiO\(_{2}\) layers deposited in the ALD process on AISI 316LVM steel intended for applications in urology. steel was subjected to electrolytic polishing and chemical passivation and was coated with a oxide layer of TiO\(_{2}\) in a low temperature ALD process with predetermined variable number of cycles and a constant temperature T = 200 \(^{\circ }\)C of the process. Were analysed processes of 500, 1250 and 2500 of cycles. The paper shows the results of macroscopic evaluation, study of wettability and surface roughness, potentiodynamic test of pitting corrosion resistance and electrochemical impedance spectroscopy EIS in a solution of artificial urine. Based on these results usefulness of the proposed TiO\(_{2}\) layers on the AISI 316LVM stainless steel was assessed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Aarik, L., Arroval, T., Rammula, R., Mandar, H., Sammelselg, V., Aarik, J.: Atomic layer deposition of TiO\(_{2}\) from TiCl\(_{4}\) and O\(_{3}\). Thin Solid Films 542, 100–107 (2013)
Bachmann, S.P., Ramage, G., VandeWalle, K., Patterson, T.F., Wickes, B.L., Lopez-Ribot, J.L.: Antifungal combinations against candida albicans biofilms in vitro. Antimicrob. Agents Chemother. 47, 3657–3659 (2003)
Basiaga, M., Paszenda, Z., Walke, W., Karasiński, P., Marciniak, J.: Electrochemical impedance spectroscopy and corrosion resistance of SiO\(_{2}\) coated cpTi and Ti-6Al-7Nb alloy. Information Technologies in Biomedicine. Advances in Intelligent Systems and Computing, vol. 284, pp. 411–420. Springer (2014)
Basiaga, M., Walke, W., Paszenda, Z., Kajzer, A.: The effect of EO and steam sterilization on mechanical and electrochemical properties of titanium grade 4. Mater. Tehnol. 50(1), 153–158 (2016)
Basiaga, M., Walke, W., Paszenda, Z., Karasiński, P., Szewczenko, J.: The effects of a SiO\(_{2}\) coating on the corrosion parameters cpTi and Ti-6Al-7Nb alloy. Biomaterials 4(1) (2014)
Basiaga, M., Walke, W., Staszuk, M.: Study of electrochemical properties of 316LVM steel with TiO\(_{2}\) layer deposited by means ALD method. In: International Conference on Advanced Computational Engineering and Experimenting—ACE-X 2015. Munich, Germany (2015)
Basiaga, M., Jendruś, R., Walke, W., Paszenda, Z., Kaczmarek, M., Popczyk, M.: Influence of surface modification on properties of stainless steel used for implants. Arch. Metall. Mater. 60(4), 2965–2969 (2015)
Borkowski, A.: Urologia: Podręcznik dla studentów medycyny. PZWL, Warszawa (2008). (in Polish)
Diaza, B., Swiatowska, J., Mauricea, V., Seyeux, A., Normand, B., Harkonen, E., Ritala, M., Marcus, P.: Electrochemical and time-of-flight secondary ion mass spectrometry analysis of ultra-thin metal oxide (Al\(_{2}\)O\({3}\) and Ta\(_{2}\)O\(_{5}\)) coatings deposited by atomic layer deposition on stainless steel. Electrochim. Acta. 56, 10516–10523 (2013)
DiTizio, V., Ferguson, G.W., Mittelman, M.W., Khoury, A.E., Bruce, A.W., DiCosmo, F.: A liposomal hydrogel for the prevention of bacterial adhesion to catheters. Biomaterials 19, 1877–1884 (1998)
Hachem, R., Reitzel, R., Borne, A., Jiang, Y., Tinkey, P., Uthamanthil, R., Chandra, J., Ghannoum, M., Raad, I.: Novel antiseptic urinary catheters for prevention of urinary tract infections: correlation of in vivo and in vitro test results. Antimicrob. Agents Chemother. 53, 5145–5149 (2009)
Houmarda, M., Nunesb, E.H.M., Vasconcelosb, D.C.L., Berthomec, G., Joudc, J.-C., Langletd, M., Vasconcelosba, W.L.: Correlation between sol-gel reactivity and wettability of silica films deposited on stainless steel. Appl. Surf. Sci. 289, 218–223 (2014)
Jacobse, S.M., Strickler, D.J., Mobley, H.L., Shirtliff, M.E.: Complicated catheter-assiociated urinary tract infections due to Escherichia coli and Proteus mirabilis. Clin. Microbiol. Rev. 21(1), 26–59 (2008)
Kajzer, A., Kajzer, W., Dzielicki, J., Matejczyk, D.: The study of physicochemical properties of stabilizing plates removed from the body after treatment of pectus excavatum. Acta. Bioeng. Biomech. 2, 35–44 (2015)
Klimek, L., Różański, W., Jabłonowski, Z., Sosnowski, M., Kliś, R.: Obserwacje zmian mikroskopowych cewników typu Double J w zależności od czasu utrzymywania ich w drogach moczowych. Inzynieria Biomaterialow 43–44, 36–39 (2005). (in Polish)
Kumagai, H., Masuda, Y., Shinagawa, T.: Self-limiting nature in atomic-layer epitaxy of rutile thin films from TiCl\(_{4}\) and H\(_{2}\)O on sapphire (001) substrates. J. Cryst. Growth 314, 146–150 (2011)
Lee, G., Marathe, S., Sabbagh, S., Crisp, J.: Thermo-expandable intra-prostatic stent in the treatment of acute urinary retention in elderly patients with significant comorbidities. Int. Urol. Nephrol. 37, 501–504 (2005)
Lim, B.S., Rahtu, A., Gordon, R.G.: Atomic layer deposition of transition metals. Nat. Mater. 2, 749–754 (2003)
Marciniak, J., Szewczenko, J., Kajzer, W.: Surface modification of implants for bone surgery. Arch. Metall. Mater. 60(3B), 2123–2129 (2015)
Opalko, F.J., Adria, J.H., Khanc, S.R.: Heterogeneous nucleation of calcium oxalate trihydrate in artificial urine by constant composition. J. Cryst. Growth 181, 410–417 (1997)
Ostrowska, K., Strzelczyk, A., Różalski, A., Strączek, P.: Biofilm bakteryjny jako przyczyna zakażeń układu moczowego—mikroorganizmy patogenne, metody prewencji i eradykacji. Postepy HigMed Dosw 67, 1027–1033 (2013). (in Polish)
Roe, D., Karandikar, B., Bonn-Savage, N., Gibbins, B., Roullet, J.B.: Antimicrobial surface functionalization of plastic catheters by silver nanoparticles. J. Antimicrob. Chemother. 61, 869–876 (2008)
Semenowicz, J., Mroczka, A., Kajzer, A., Kajzer, W., Koczy, B., Marciniak, J.: Total hip arthroplasty using cementless avantage cup in patients with risk of hip prosthesis instability. Ortop. Traumatol. Rehabil. 16(3) 07, 253–263 (2014)
Shaw, G.L., Choong, S.K., Fry, C.: Ecrustation of biomaterials in the urinary tract. Urol. Res. 33(1), 17–22 (2005)
Siva, D., Krishna, R., Sun, Y.: Thermally oxidised rutile-TiO\(_{2}\) coating on stainless steel for tribological properties and corrosion resistance enhancement. Appl. Surf. Sci. 252, 1107 (2005)
Suci, P.A., Mittelman, M.W., Yu, F.P., Geesey, G.G.: Investigation of ciprofloxacin penetration into pseudomonas aeruginosa biofilms. Antimicrob. Agents Chemother. 38, 2125–2133 (1994)
Szewczenko, J., Jaglarz, J., Basiaga, M., Kurzyk, J., Skoczek, E., Paszenda, Z.: Topografia i grubość warstw pasywnych na utlenianym anodowo stopie Ti6Al4V. Przeglad elektrotechniczny 88(12B), 228–231 (2012) (in Polish)
Szewczenko, J., Jaglarz, J., Basiaga, M., Kurzyk, J., Paszenda, Z.: Optical methods applied in thickness and topography testing of passive layers on implantable titanium alloys. Opt. Appl. 43(1), 173–180 (2013)
Trupti, A., Lauserpina, C., Shanta, M.: Efficacy of a silicone urinary catheter impregnated with chlorhexidine and triclosan against colonization with proteus mirabilis and other uropathogens. Infect. Control Hosp. Epidemiol. 28, 596–598 (2007)
Walke, W., Paszenda, Z., Basiaga, M., Karasiński, P., Kaczmarek, M.: EIS study of SiO\(_{2}\) oxide film on 316L stainless steel for cardiac implants. Information Technologies in Biomedicine. Advances in Intelligent Systems and Computing, vol. 284, pp. 403–410. Springer (2014)
Walke, W., Paszenda, Z., Karasiński P., Marciniak, J., Basiaga, M.: Investigations of mechanical properties of SiO\(_{2}\)/TiO\(_{2}\) coatings deposited by sol–gel method on cpTi and Ti6Al7Nb. In: Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Xu. L.C.: Effect of surface wettability and contact time on protein adhesion to biomaterial surfaces. Biomaterials 28, 3273–3283 (2007)
Yao, Y., Ohko, Y., Sekiguchi, Y., Fujishima, A., Kubota, Y.: Self-sterilization using silicone catheters coated with Ag and TiO\(_{2}\) nanocomposite thin film. J. Biomed. Mater. Res. B Appl. Biomater. 85, 453–460 (2008)
Zabel, M.: Histologia. Podręcznik dla studentów medycyny i stomatologii. Elsevier Urban and Partner (2013) (in Polish)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Kajzer, W., Kajzer, A., Grygiel-Pradelok, M., Ziębowicz, A., Ziębowicz, B. (2016). Evaluation of Physicochemical Properties of TiO\(_{2}\) Layer on AISI 316LVM Steel Intended for Urology. In: Piętka, E., Badura, P., Kawa, J., Wieclawek, W. (eds) Information Technologies in Medicine. ITiB 2016. Advances in Intelligent Systems and Computing, vol 472. Springer, Cham. https://doi.org/10.1007/978-3-319-39904-1_34
Download citation
DOI: https://doi.org/10.1007/978-3-319-39904-1_34
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-39903-4
Online ISBN: 978-3-319-39904-1
eBook Packages: EngineeringEngineering (R0)