Abstract
The design process of a wearable robotic device for human assistance requires the characterization of both kinetic and kinematic parameters (KKP) of the human joints. The first step in this process is to extract the KKP from different gait analyses studies. This work is based on the human lower limb considering the following activities of daily living (ADL): walking over ground, stairs ascending/descending, ramp ascending/descending and chair standing up. The usage of different gait analyses in the characterization process, causes the data to have great variations from one study to another. Therefore, the data is graphically represented using Matlab® and Excel® to facilitate its assessment. Finally, the characterization of the KKP performed was proved to be useful in assessing the data reliability by directly comparing all the studies between each other; providing guidelines for the selection of actuator capacities depending on the end application; and highlighting optimization opportunities such as the implementation of agonist-antagonist actuators for particular human joints.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Panizzolo, F., Galiana, I., Asbeck, A.T., Siviy, C., Schmidt, K., Holt, K.G., Walsh, C.J.: A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking. J. Neuroeng. Rehabil. 1–13 (2016). doi:10.1186/s12984-016-0150-9
Menguc, Y., Park, Y.-L., Pei, H., Vogt, D., Aubin, P.M., Winchell, E., Fluke, L., Stirling, L., Wood, R.J., Walsh, C.J.: Wearable soft sensing suit for human gait measurement. Int. J. Rob. Res. 33, 1748–1764 (2014). doi:10.1177/0278364914543793
Wu, S.K., Waycaster, G., Shen, X.: Electromyography-based control of active above-knee prostheses. Control Eng. Pract. 19, 875–882 (2011). doi:10.1016/j.conengprac.2011.04.017
Bovi, G., Rabuffetti, M., Mazzoleni, P., Ferrarin, M.: A multiple-task gait analysis approach: kinematic, kinetic and EMG reference data for healthy young and adult subjects. Gait Posture 33, 6–13 (2011). doi:10.1016/j.gaitpost.2010.08.009
Lee, S.J., Hidler, J.: Biomechanics of overground vs. treadmill walking in healthy individuals. J. Appl. Physiol. 104, 747–755 (2008). doi:10.1152/japplphysiol.01380.2006
Han, Y., Wang, X.: The biomechanical study of lower limb during human walking. Sci. China Technol. Sci. 54, 983–991 (2011). doi:10.1007/s11431-011-4318-z
Yali, H., Xingsong, W.: Biomechanics study of human lower limb walking: implication for design of power-assisted robot. In: 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems. pp. 3398–3403. IEEE, Taipei, Taiwan (2010). doi:10.1109/IROS.2010.5650497
Moore, J.K., Hnat, S.K., van den Bogert, A.J.: An elaborate data set on human gait and the effect of mechanical perturbations. PeerJ 3, e918 (2015). doi:10.7717/peerj.918
Protopapadaki, A., Drechsler, W.I., Cramp, M.C., Coutts, F.J., Scott, O.M.: Hip, knee, ankle kinematics and kinetics during stair ascent and descent in healthy young individuals. Clin. Biomech. 22, 203–210 (2007). doi:10.1016/j.clinbiomech.2006.09.010
Riener, R., Rabuffetti, M., Frigo, C.: Stair ascent and descent at different inclinations. Gait Posture. 15, 32–44 (2002). doi:10.1016/S0966-6362(01)00162-X
McIntosh, A.S., Beatty, K.T., Dwan, L.N., Vickers, D.R.: Gait dynamics on an inclined walkway. J. Biomech. 39, 2491–2502 (2006). doi:10.1016/j.jbiomech.2005.07.025
Roebroeck, M.E., Doorenbosch, C.A.M., Harlaar, J., Jacobs, R., Lankhorst, G.J.: Biomechanics and muscular activity during sit-to-stand transfer. Clin. Biomech. 9, 235–244 (1994). doi:10.1016/0268-0033(94)90004-3
Mak, M.K.Y., Levin, O., Mizrahi, J., Hui-Chan, C.W.Y.: Joint torques during sit-to-stand in healthy subjects and people with Parkinson’s disease. Clin. Biomech. 18, 197–206 (2003). doi:10.1016/S0268-0033(02)00191-2
Rowe, P.J., Myles, C.M., Walker, C., Nutton, R.: Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life? Gait Posture 12, 143–155 (2000). doi:10.1016/S0966-6362(00)00060-6
Reid, S.M., Lynn, S.K., Musselman, R.P., Costigan, P.A.: Knee biomechanics of alternate stair ambulation patterns. Med. Sci. Sport. Exerc. 39, 2005–2011 (2007). doi:10.1249/mss.0b013e31814538c8
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer International Publishing AG
About this paper
Cite this paper
Solis-Ortega, R.D., Dehghani-Sanij, A.A., Martinez-Hernandez, U. (2017). Characterization of Kinetic and Kinematic Parameters for Wearable Robotics. In: Gao, Y., Fallah, S., Jin, Y., Lekakou, C. (eds) Towards Autonomous Robotic Systems. TAROS 2017. Lecture Notes in Computer Science(), vol 10454. Springer, Cham. https://doi.org/10.1007/978-3-319-64107-2_44
Download citation
DOI: https://doi.org/10.1007/978-3-319-64107-2_44
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-64106-5
Online ISBN: 978-3-319-64107-2
eBook Packages: Computer ScienceComputer Science (R0)