Abstract
In order to troubleshoot the distribution transformer open-phase faults, a GSM network was set up, which could transmit open-phase information to the monitoring center automatically. From the analysis of short message in the monitoring center, system can find the person from the database who is in charge of the transformer, and sends messages to him through the serial port on the GSM. So, the maintenance personnel can troubleshoot the faults in time. A monitoring software method was designed under Visual C ++ platform. The AP1 function can be used to initialize, open and close the serial port. Based on the GSM protocol, we can write code to initialize the GSM modem, write and read SMS function in the chips. From the transformer and the person in charge information database which based on the MySQL, the system can store the information about the all working information of transformers. The use of multi-threading technology is to manage of the serial on the sending and reading short message in the same time. This design of the software has operated in several hot-points, and shows its high reliability and stability in troubleshoot open-phase faults.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
We’re sorry, something doesn't seem to be working properly.
Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.
References
Guan, E.-H., Shang, C.-J., Zhang, X.-F.: Sending SMS Using PC through Serial Port under VC++ Environment. Application Research of Computers (8), 215–216, 219 (2005)
Liu, X.-R.: Display and Access Picture in Database by VC++. Application Research of Computers (5), 163–165 (2006)
Li, Z.-F.: Effects on Open-Phase Operation of Rural Power Supply. Rural Electrician (11), 23 (2005)
Li, C.-L.: Analysis on 35kv Transformer Open-Phase Operation. Jiangsu Electrical Engineering 24(1), 34–36 (2005)
Zhang, Y.-C.: An Analysis of the First Winding of Transformerat the End of Grid Open Circuit. Journal of Xingjiang University 18(4), 479–480, 492 (2001)
Wang, Z.-P.: Phase-lacking Fault Protection due to Drop-fuse for 35 kV Transformer. Journal of Noth China Electric Power Univercity 28(2), 24–26 (2011)
Gao, X.-Y., Wang, F.: Combined Transformer Open-Phase Protection. Transformers 40(6), 42–43 (2003)
Zheng, F.-W.: The Open-Phase Protection on American Transformers. Operation & Mentenance (8) (2007)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Copyright information
© 2012 Springer-Verlag GmbH Berlin Heidelberg
About this chapter
Cite this chapter
Wang, Yz., Lou, FD., Ye, J., Zhu, Zh., Jiang, C., He, W. (2012). A Distribution Transformer Open-Phase Fault Location System Based on VC++. In: Sambath, S., Zhu, E. (eds) Frontiers in Computer Education. Advances in Intelligent and Soft Computing, vol 133. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-27552-4_149
Download citation
DOI: https://doi.org/10.1007/978-3-642-27552-4_149
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-27551-7
Online ISBN: 978-3-642-27552-4
eBook Packages: EngineeringEngineering (R0)