Abstract
For augmented fluoroscopy in the context of minimally invasive EP procedures, a patient-specific model of the atrium segmented from a 3D volume can be overlaid on fluoroscopic images. This requires a registration between the 3D model coordinate system and the coordinate system of the C-arm X-ray device. We propose an indirect registration that makes use of surrounding anatomical structures that can be segmented both in the 3D volume obtained by CT or MRI and also in fluoroscopic images. More precisely, the coronary sinus and the esophagus segmented from the 3D volume is registered to reconstructed 3D devices which are located in the respective structures during the intervention. An evaluation on 6 images of 6 different patients yielded a mean registration error of 3.2mm. Results became significantly worse if only one of the anatomical structures was used.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Calkins H, Brugada J, Packer DL, et al. HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. Europace. 2007;9(6):335–79.
Ector J, Buck SD, Huybrechts W, et al. Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation: accuracy and clinical value. Heart Rhythm. 2008;5(7):957–64.
Hoffmann M, Bourier F, Strobel N, et al. structure-enhancing visualization for manual registration in fluoroscopy. Proc BVM. 2013; p. 241–6.
Zhao X, Miao S, Du L, et al. Robust 2-D/3-D registration of cT volumes with contrast-enhanced X-ray sequences in electro-physiology based on a weighted similarity measure and sequential subspace optimization. Proc IEEE Int Conf Acoust Speech Signal Process ICASSP. 2013; p. 934–8.
Sra J, Krum D, Malloy A, et al. Registration of three-dimensional left atrial computed tomographic images with projection images obtained using fluoroscopy. Circulation. 2005;112(24):3763–8.
Brost A, Bourier F, Yatziv L, et al. First steps towards initial registration for electrophysiology procedures. Med Imaging Vis Image-Guided Proced Model. 2011;7964(1).
Besl PJ, McKay ND. A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell. 1992;14(2):239–56.
Fieselmann A, Lautenschl¨ager S, Deinzer F, et al. Esophagus segmentation by spatially-constrained shape interpolation. Proc BVM. 2008; p. 247–51.
Hoffmann M, Brost A, Koch M, et al. Electrophysiology catheter detection and reconstruction from two views in fluoroscopic images. Trans Med Imaging. 2015;ahead of print.
King AP, Boubertakh R, Rhode KS, et al. A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures. Med Image Anal. 2009;13(3):419–31.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Hoffmann, M., Strobel, N., Maier, A. (2016). Registration of Atrium Models to C-arm X-ray Images Based on Devices Inside the Coronary Sinus and the Esophagus. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2016. Informatik aktuell. Springer Vieweg, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-49465-3_17
Download citation
DOI: https://doi.org/10.1007/978-3-662-49465-3_17
Publisher Name: Springer Vieweg, Berlin, Heidelberg
Print ISBN: 978-3-662-49464-6
Online ISBN: 978-3-662-49465-3
eBook Packages: Computer Science and Engineering (German Language)