Abstract
A questionnaire was mailed to 708 practicing radiologists and 348 members of the Society for Computer applications in Radiology (SCAR) in order to evaluate current practices and attitudes regarding the perceived advantages or disadvantages of film- and CRT-based image interpretation. A total of 27% of the 1,056 questionnaires (137 practicing radiologists; 145 SCAR members were returned. Ninety percent of practicing radiologists used film at least 75% of the time. Advantages of film-based reading listed by more than 75% of the respondents included: film reading is faster, and facilitates viewing multiple images. Advantages of CRT-based reading included: access to the entire dynamic range and potential image processing. Desirable attributes of existing displays included: adjustable grey scale, magnification, ability to view multiple images, allow quick review, and viewing by several individuals. Valued potential advances included: multiple higher resolution monitors, image processing and multimodality display. Practicing radiologists and computer applications society members had similar attitudes. Film-based reading is still nearly universal, but radiologists are interested in CRT-based reading if such devices have the proper features and become more available.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Wells PN: Display of visual information, in: Hendee WR, Wells PNT (eds): Visualization Science in Engineering, Computing and Medicine. An International Workshop Sponsored by the American College of Radiology. Reston, VA, American College of Radiology, 1988, pp 22–25
Huang HK, Rutherford HG, O’Hare J, et al: Ergonomics of the imaging workstation, in: Hendee WR, Wells PNT (eds), ACR report: Engineering Research in Visual Perception. Reston, VA, American College of Radiology, 1986
American National Standard for Human Factors Engineering of Visual Display Terminal Workstations: Santa Monica, CA, The Human Factors Society, 1988
Farrell RJ, Booth JM: Design handbook for imagery interpretation equipment. Seattle, WA, Boeing Aerospace Co, 1984, section 6.1–6.10
Pizer SM, Beard DV: Medical image workstations: Functions and implementation. J Digit Imag 2:185–193, 1989
Kazan B: New electronic displays and their possibilities for radiology. Invest Radiol 24:817–819, 1989
Foley DW, Jacobsen DR, Taylor AJ, et al: Display of CT studies on a two-screen electronic workstation versus a film panel alternator: Sensitivity and efficiency among radiologists. Radiology 174:769–773, 1990
Fisher P, Grover B, Brauer G, et al: Digital image display station performance requirements based on physician experience with a prototype system. J Digit Imag 2:150–155, 1989
Siegel S: Non-parametric statistics. New York, NY, McGraw-Hill, 1956
Author information
Authors and Affiliations
Additional information
Supported in part by USPHS Grants RO1-CA40444, PO1-CA41167 and T32-CA09536.
Rights and permissions
About this article
Cite this article
Coughlin, B.F., Seltzer, S.E., Swensson, R.G. et al. Practices and attitudes about cathode-ray tube-based and film-based image interpretation. J Digit Imaging 5, 50–53 (1992). https://doi.org/10.1007/BF03167823
Issue Date: