Abstract
There has been recent interest in using video cameras along with computer vision and photogrammetric techniques to aid in the daily positioning of patients for radiation therapy. We describe here a method to calibrate video cameras to the beam coordinate system of a radiation therapy treatment machine. Standard camera calibration relates the three-dimensional coordinate system of a calibration phantom to the two-dimensional image coordinates. Using a calibration phantom designed for simultaneous X-ray and video imaging, both types of images can be calibrated to a single coordinate system. A series of X-ray images of the calibration phantom is taken using the motion of the treatment machine. Camera calibration parameters derived from these images are used to find a transformation from the coordinate system of the calibration phantom to the beam coordinate system of the treatment machine. This transformation is applied to the video camera calibration to provide a camera calibration directly to the beam coordinates of the machine.
Chapter PDF
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Kenneth G.A. Gilhuijs, Automatic verification of radiation treatment geometry, Ph.D. thesis, University of Amsterdam, 1995.
Markus Menke, Frank Hirschfeld, Thomas Mack, Otto Pastyr, Volker Sturm, Wolfgang Schegel, “Photgrammetirc accuracy measurements of a head holder system used for fractionated radiotherapy,” Int. J. Radiat. Oncol. Biol. Phys., vol. 29, no. 5, pp. 1147–1155, 1994.
B.D. Milliken, S.J. Rubin, R.J. Hamilton, L.S. Johnson, G.T.Y. Chen, “Performance of a video-image-subtraction-based patient positioning system,” Int. J. Radiat. Oncol. Biol. Phys., vol. 38, no. 4, pp. 855–866, 1997.
Roger Y. Tsai, “A versatile camera calibration technique for high-accuracy 3d machine vision metrology using off-the-shelf TV camera and lenses,” IEEE Journal of Robotics and Automation, vol. RA-3, no. 4, pp. 323–344, 1987.
Paul P. Richard, Robot Manipulators, MIT Press, 1984.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1998 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Hadley, S.W., Johnson, L.S., Pelizzari, C.A. (1998). Calibration of video cameras to the coordinate system of a radiation therapy treatment machine. In: Wells, W.M., Colchester, A., Delp, S. (eds) Medical Image Computing and Computer-Assisted Intervention — MICCAI’98. MICCAI 1998. Lecture Notes in Computer Science, vol 1496. Springer, Berlin, Heidelberg. https://doi.org/10.1007/BFb0056205
Download citation
DOI: https://doi.org/10.1007/BFb0056205
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-65136-9
Online ISBN: 978-3-540-49563-5
eBook Packages: Springer Book Archive