Abstract
A post-processing ”autofocusing” algorithm for the reduction of motion artifacts in MR images has been developed and tested on a large clinical data set of high resolution shoulder images. The algorithm uses only the raw (complex) data from the MR scanner, and requires no knowledge of the patient motion during the scan, deducing that from the raw data itself. It operates by searching over the space of possible patient motions and optimizing the image quality. Evaluation of this technique on the clinical data set (for which navigator echo based measured motions and corrected images were available) show that the algorithm can correct for the effects of global translation during the scan almost as well as the navigator echo approach and is more robust.
Chapter PDF
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Ehman RL, Felmlee JP. Actaptive technique for high-definition MR imaging of moving structures. Radiology 1989; 173:225–263.
Atkinson D, Hill DL, Stoyle PN, Summers PE, Keevil SF. Automatic correection of motion artifacts in magnetic resonance images using an entropy focus criterion. IEEE Trans Med Img 1997; 16(6):903–910.
McGee KP, Grimm RC, Felmlee JP, Rydberg JR, Riederer SJ, Ehman RL. The shoulder: Actaptive motion correction of MR images. Radiology 1997; 205:341–354.
Bocker RP, Jones SA. ISAR motion compensation using the burst derivative measure as a focal quality indicator. Int J Imag Syst Technol 1992; 4:285–297.
Stoffa PL, Sen MK. Nonlinear multiparameter optimization using genetic algorithms: inversion of plane-wave seismograms. Geophysics 1991; 56:1794–1810.
Welch EB, Manduca A, Ehman RL. Fast autofocusing of motion-corrupted MR images using one-dimensional Fourier transforms. Proc SPIE Med Img 1998; 3338:391–397.
McGee KP, Manduca A, Felmlee JP, Grimm RC, Riederer SJ, Ehman RL. Auto-correction of high resolution shoulder MR images: analysis of image metrics. Proc ISMRM 1998.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1998 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Manduca, A., McGee, K.P., Welch, E.B., Felmlee, J.P., Ehman, R.L. (1998). Autofocusing of clinical shoulder MR images for correction of motion artifacts. In: Wells, W.M., Colchester, A., Delp, S. (eds) Medical Image Computing and Computer-Assisted Intervention — MICCAI’98. MICCAI 1998. Lecture Notes in Computer Science, vol 1496. Springer, Berlin, Heidelberg. https://doi.org/10.1007/BFb0056245
Download citation
DOI: https://doi.org/10.1007/BFb0056245
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-65136-9
Online ISBN: 978-3-540-49563-5
eBook Packages: Springer Book Archive