Abstract
A portable bienzymatic analytical system was developed for the chronoamperometric analysis of methanol–ethanol mixtures. The system consists of two biosensors, one based on alcohol dehydrogenase (ADH) that responds only to the ethanol and the second one based on alcohol oxidase (AOX) that responds to both methanol and ethanol. The transducers were screen-printed electrodes (SPEs) modified with mediators: Meldola blue for ADH and Co-phthalocyanine for AOX. The calibration graph of the ADH biosensor is linear between 0.3 and 8 mmol/L ethanol. The AOX biosensor is able to quantify both analytes in mixtures that contain methanol between 3 and 70 mmol/L and ethanol ranging from 15 to 110 mmol/L. Interferences due to non-specific oxidations from common oxidizable compounds like gallic acid and ascorbic acid were smaller in the case of transducer based on Meldola blue. The analytical system was successfully tested on real samples: non-alcoholised beer (NAB) spiked with ethanol or methanol and a falsified rose wine (FRW).
Similar content being viewed by others
Abbreviations
- ADH:
-
Alcohol dehydrogenase
- AOX:
-
Alcohol oxidase
- SPEs:
-
Screen-printed electrodes
- WE:
-
Working electrode
- NAD+/NADH:
-
Nicotinamide adenine dinucleotide oxidized/reduced forms
- FAD:
-
Flavin adenine dinucleotide
- K M :
-
Michaelis constant
- PVA-SbQ:
-
Polyvinyl alcohol containing stilbazolium groups
- NAB:
-
Non-alcoholic beer
- FRW:
-
Falsified rose wine
References
van Wyk JPH (2001) Trends Biotech 19:172–177. doi:10.1016/S0167-7799(01)01601-8
Jacobs P, Dewé W, Flament A, Gibella M, Ceccato A (2006) J Pharm Biomed Anal 40(2):294–304. doi:10.1016/j.jpba.2005.06.036
Klein H, Leubolt R (1993) J Chromatogr A 640(1–2):259–270. doi:10.1016/0021-9673(93)80189-F
Harmon BJ, Patterson DH, Regnier FE (1993) J Chromatogr A 657(2):429–434. doi:10.1016/0021-9673(93)80298-M
Azmak D (2006) Leg Med 8(1):39–42. doi:10.1016/j.legalmed.2005.07.002
Azevedo AM, Prazeres DMF, Cabral JMS, Fonseca LP (2005) Biosens Bioelectr 21:235–247. doi:10.1016/j.bios.2004.09.030
Sekine Y, Suzuki M, Takeuchi T, Tamiya E, Karube I (1993) Anal Chim Acta 280:179–184. doi:10.1016/0003-2670(93)85119-5
de Prada GV, Pena N, Mena ML, Reviejo AJ, Pingarron JM (2003) Biosens Bioelectr 18:1279–1288. doi:10.1016/S0956-5663(03)00074-5
Gulce H, Gulce A, Kavanoz M, Coskun H, Yildiz A (2002) Biosens Bioelectr 17:517–521. doi:10.1016/S0956-5663(02)00008-8
Avramescu A, Noguer T, Magearu V, Marty JL (2001) Anal Chim Acta 433:81–88. doi:10.1016/S0003-2670(01)00823-6
Bucur B, Mallat E, Gurban AM, Gocheva Y, Velasco C, Marty JL, Noguer T (2006) Biosens Bioelectr 21(12):2290–2297. doi:10.1016/j.bios.2005.10.022
Andreescu S, Barthelmebs L, Marty JL (2002) Anal Chim Acta 464:171–180. doi:10.1016/S0003-2670(02)00518-4
Chaubey A, Malhotra BD (2002) Biosens Bioelectr 17:441–456. doi:10.1016/S0956-5663(01)00313-X
Gorton L, Dominguez E (2002) Rev Mol Biotechnol 82:371–392. doi:10.1016/S1389-0352(01)00053-8
Jordan J, Ciolkosz MK (1991) J Solut Chem 20(10):995–1000. doi: 10.1007/BF00663998
Vasilescu A, Noguer T, Andreescu S, Calas-Blanchard C, Bala C, Marty JL (2003) Talanta 59:751–765. doi:10.1016/S0039-9140(02)00614-8
Abass AK, Hart JP, Cowell DC, Chappell A (1998) Anal Chim Acta 373(1):1–8. doi:10.1016/S0003-2670(98)00368-7
Curulli A, Valentini F, Orlanduci S, Terranova ML, Palleschi G (2004) Biosens Bioelectr 20:1223–1232. doi:10.1016/j.bios.2004.06.026
Gilmartin MAT, Hart JP, Birch BJ (1994) Analyst 119:243–252. doi: 10.1039/AN9941900243
Gilmartin MAT, Hart JP (1994) Analyst 119:2331–2336. doi: 10.1039/AN9941902331
Leca B, Marty JL (1997) Biosens Bioelectr 12:1083–1088. doi:10.1016/S0956-5663(97)00075-4
Lushine KA, Harris CR, Holger JS (2003) J Emerg Med 24(4):433–436. doi:10.1016/S0736-4679(03)00041-6
Acknowledgements
Bucur Bogdan is a post-doctoral fellow of Romanian Ministry of Education and Research through Grant PD-011/2005. The work was supported by Romanian Ministry of Education and Research through Grant CEEX-156/2006. The Meldola blue modified screen-printed paste was a gift from Gwent Electronic Materials (UK). The authors wish to thank Prof. Jean-Louis Marty (BIOMEM-University of Perpignan, France) for the SPEs and PVA polymer and Prof. Didier Fournier (Paul Sabatier University, Toulouse, France) for helpful discussions on enzymatic kinetic.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bucur, B., Radu, G.L. & Toader, C.N. Analysis of methanol–ethanol mixtures from falsified beverages using a dual biosensors amperometric system based on alcohol dehydrogenase and alcohol oxidase. Eur Food Res Technol 226, 1335–1342 (2008). https://doi.org/10.1007/s00217-007-0662-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00217-007-0662-4