Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Endoscopy system for length measurement by manual pointing with an electromagnetic tracking sensor

  • Regular Papers
  • Published:
Optical Review Aims and scope Submit manuscript

Abstract

We propose a practical and simple measurement function of three dimensional (3D) length for endoscopy based on triangulation using manually pointed correspondences. This system is a novel combination of conventional methods. 3D length information is useful for many medical purposes and the burden of manual procedures can be reduced by focusing on length. We employed a novel combination for length measurement, that is, a monocular endoscope with an electromagnetic tracking sensor. The proposed method can measure the length without any equipment for light projection and changing the current procedure of endoscopy. Our method is made more robust and reliable than the automatic correspondence techniques through the best use of the expertise of endoscopists. We developed a prototype system and evaluated its accuracy. From experimental results, we showed that the proposed method can measure the 3D length of static objects accurately as long as the measurement geometry is suitable.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. Sonnenberg, M. Giger, L. Kern, C. Noll, K. Stuby, K. B. Weber, and A. L. Blum: Br. Med. J. 2 (1979) 1322.

    Article  Google Scholar 

  2. K. Deguchi and T. Okatani: Proc. IEEE/SIAM Joint Workshop Mathematical Methods in Biomedical Image Analysis, 1996, p. 290.

  3. H. Haneishi, T. Ogura, and Y. Miyake: Opt. Lett. 19 (1994) 601.

    Article  ADS  Google Scholar 

  4. K. Hasegawa, K. Noda, and Y. Sato: Proc. Int. Conf. Pattern Recognition, 2002, p. 792.

  5. D. Yelin, I. Rizvi, W. M. White, J. T. Motz, T. Hasan, B. E. Bouma, and G. J. Tearney: Nature 443 (2006) 765.

    Article  ADS  Google Scholar 

  6. M. Chan, W. Lin, C. Zhou, and J. Y. Qu: Appl. Opt. 42 (2003) 1888.

    Article  ADS  Google Scholar 

  7. H. Nakatani, K. Abe, A. Miyakawa, and S. Terakawa: J. Biomed. Opt. 12 (2007) 051803.

    Article  ADS  Google Scholar 

  8. N. Oda, J. Hasegawa, T. Nonami, M. Yamaguchi, and N. Ohyama: Opt. Rev. 2 (1995) 110.

    Article  Google Scholar 

  9. K. Deguchi, T. Sasano, H. Arai, and H. Yoshikawa: IEICE Trans. Inf. Syst. E79-D (1996) 1329.

    Google Scholar 

  10. K. Yao, T. Matsui, H. Furukawa, T. Yao, T. Sakurai, and T. Mitsuyasu: Gastrointest. Endosc. 55 (2002) 412.

    Article  Google Scholar 

  11. D. Koppel, C.-I. Chen, Y.-F. Wang, H. Lee, J. Gu, A. Poirson, and R. Wolters: Proc. SPIE 6509 (2007) 65091L.

    Article  Google Scholar 

  12. D. G. Lowe: Int. J. Comput. Vision 60 (2004) 91.

    Article  Google Scholar 

  13. G. Bradski and A. Kaebler: Learning OpenCV (O’Reilly, Sebastopol, CA, 2008).

    Google Scholar 

  14. R. Horaud and F. Dornaika: Int. J. Robot Res. 14 (1995) 195.

    Article  Google Scholar 

  15. T. Grossman and R. Balakrishnan: ACM Trans. Comput.-Hum. Interaction 12 (2005) 435.

    Article  Google Scholar 

  16. J. O. Wobbrock, E. Cutrell, S. Harada, and I. S. MacKenzie: Proc. 26th Annu. SIGCHI Conf. Human Factors in Computing Systems, 2008, p. 1613.

  17. S. Zhai, J. Kong, and X. Ren: Int. J. Hum.-Comput. Stud. 61 (2004) 823.

    Article  Google Scholar 

  18. V. Vezhnevets and A. Velizhev: GML C++ Camera Calibration Toolbox (2005) [http://research.graphicon.ru/calibration/gml-c++-camera-calibration-toolbox.html].

  19. R. Hartley and A. Zisserman: Multiple View Geometry in Computer Vision (Cambridge University Press, Cambridge, U.K., 2003).

    Google Scholar 

  20. M. Nakamoto, K. Nakada, Y. Sato, K. Konishi, M. Hashizume, and S. Tamura: IEEE Trans. Med. Imaging 27 (2008) 255.

    Article  Google Scholar 

  21. M. Feuerstein, T. Reichl, J. Vogel, A. Schneider, H. Feussner, and N. Navab: Proc. Medical Image Computing and Computer-Assisted Intervention, 2007, LNCS 4791, p. 458.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takeshi Koishi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Koishi, T., Sasaki, M., Nakaguchi, T. et al. Endoscopy system for length measurement by manual pointing with an electromagnetic tracking sensor. OPT REV 17, 54–60 (2010). https://doi.org/10.1007/s10043-010-0010-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10043-010-0010-y

Keywords