Abstract
Arsenic is a widespread contaminant in the environment. The intake of water containing high concentrations of arsenic could have serious impact on human health, such as skin and lung cancer. In the European Union, thus, also in Italy, the arsenic limit in drinking water is 10 μg L−1. Several water remediation treatment technologies are available for arsenic removal. For some processes, the removal efficiencies can be improved after an oxidation step. Most full-scale applications are based on conventional oxidation processes for chemical micropollutant removal. However, if water contains arsenic and refractory organic contaminants, the advanced oxidation processes could be considered. The aim of this work was to investigate the effectiveness of ultraviolet (UV) radiation alone and in combination with hydrogen peroxide for the oxidation of arsenic and terbuthylazine (TBA). The experimental tests were performed in groundwater at the laboratory scale (0.1 mg L−1 As(III) and 10 μg L−1 TBA). Hydrogen peroxide alone (15 mg L−1) was ineffective on both arsenic and TBA oxidation; the 253.7-nm radiation alone did not oxidize arsenic(III), but photolyzed efficiently TBA (52 % removal yield at a UV dose of 1,200 mJ cm−2). The UV/H2O2 advanced oxidation (UV dose 600–2,000 mJ cm−2, 5–15 mg L−1 H2O2) was the most effective process for the oxidation of both arsenic and TBA, with observed oxidation efficiencies of 85 and 94 %, respectively, with 5 mg L−1 H2O2 and a UV dose of 2,000 mJ cm−2.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
APAT–IRSA (2003). APAT and IRSA 5060. Metodi analitici per le acque: prodotti fitosanitari (antiparassitari e pesticidi). Manuale e Linee Guida 29.5 (analytical methods for water: phytosanitary products (pesticides)). Manual and guidelines 29.5, pp. 661–678. Rome: APAT–IRSA
Bissen, M., & Frimmel, F. H. (2003). Arsenic—a review. Part II: oxidation of arsenic and its removal in water treatment. Acta Hydrochimica et Hydrobiologica, 31(2), 97–107.
Bolton, J. R., & Linden, K. G. (2003). Standardization of methods for fluence (UV dose) determination in bench-scale experiments. Journal of Environmental Engineering, 129(3), 209–216.
Bolton, J. R., & Stefan, M. I. (2002). Fundamental photochemical approach to the concepts of fluence (UV dose) and electrical energy efficiency in photochemical degradation reactions. Research on Chemical Intermediates, 28(7–9), 857–870.
Chiron, S., Fernandez-Alba, A., Rodriguez, A., & Garcia-Calvowat, E. (2000). Pesticide chemical oxidation: state-of-the-art. Water Research, 34(2), 366–377.
Ghurye, G., & Clifford, D. (2004). As(III) oxidation using chemical and solid-phase oxidants. Journal - American Water Works Association, 96(1), 84–96.
ISPRA (2013). Rapporto nazionale pesticidi nelle acque - dati 2009–2010 - Edizione 2013. Rapporti 175/2013. Rome: ISPRA.
Lànyi, K., & Dinya, Z. (2005). Photodegradation study for assessing the environmental fate of some triazine-, urea- and thiolcarbamate-type herbicides. Microchemical Journal, 80, 79–87.
Minero, C., Pramauro, E., Pelizzetti, E., Dolci, M., & Marchesini, A. (1992). Photosensitized transformations of atrazine under simulated sunlight in aqueous humic acid solution. Chemosphere, 24(11), 1597–1606.
Nick, K., Schöler, H. F., Mark, G., Söylemez, T., Akhlaq, M. S., Schuchmann, H. P., et al. (1992). Degradation of some triazine herbicides by UV radiation such as used in the UV disinfection of drinking water. Journal of Water Supply: Research and Technology - Aqua, 41(2), 82–87.
Ormad, M. P., Miguel, N., Claver, A., Matesanz, J. M., & Ovelleiro, J. L. (2008). Pesticides removal in the process of drinking water production. Chemosphere, 71, 97–106.
Palm, W. U., Kopetzky, R., & Ruck, W. (2003). OH-radical reactivity and direct photolysis of triphenyltin hydroxide in aqueous solution. Journal of Photochemistry and Photobiology A: Chemistry, 156, 105–114.
Sanlaville, Y., Guittonneau, S., Mansour, M., Feicht, E. A., Meallier, P., & Kettrup, A. (1996). Photosensitized degradation of terbuthylazine in water. Chemosphere, 33(2), 353–362.
Sorlini, S., & Gialdini, F. (2010). Conventional oxidation treatments for the removal of arsenic with chlorine dioxide, hypochlorite, potassium permanganate and monochloramine. Water Research, 44, 5653–5659.
Sorlini, S., Gialdini, F., & Stefan, M. (2010). Arsenic oxidation by UV radiation combined with hydrogen peroxide. Water Science and Technology, 61(2), 339–344.
Yang, H., Lin, W. Y., & Rajeshwar, K. (1999). Homogeneous and heterogeneous photocatalytic reactions involving As(III) and As(V) species in aqueous media. Journal of Photochemistry and Photobiology A: Chemistry, 123, 137–143.
WHO (2003). Terbuthylazine (TBA) in drinking-water. Background document for development of guidelines for drinking-water quality. Report WHO/SDE/WSH/03.04/63. Geneva: WHO.
WHO. (2011). Guidelines for drinking-water quality (4th ed.). Geneva: WHO.
Zaw, M., & Emett, M. (2002). Arsenic removal from water using advanced oxidation processes. Toxicology Letters, 133, 113–118.
Acknowledgments
The authors thank Trojan Technologies for the collaboration in the research project. Special thanks are also given to engineer Valerio Zani for supporting this experimental work. Dr. Sabrina Sorlini supervised the experimental work and data analysis. Dr. Francesca Gialdini carried out the experimental test and data analysis. Dr. Stefan Mihaela was the external collaborator and advised on the experimental protocol and data interpretation.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sorlini, S., Gialdini, F. & Stefan, M. UV/H2O2 oxidation of arsenic and terbuthylazine in drinking water. Environ Monit Assess 186, 1311–1316 (2014). https://doi.org/10.1007/s10661-013-3481-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10661-013-3481-z