Abstract
Ventriculomegaly is the most commonly detected abnormality in neonatal brain. It can be defined as a condition when the human brain ventricle system becomes dilated. This in turn increases the intracranial pressure inside the skull resulting in progressive enlargement of the head. Sometimes it may also cause mental disability or death. For these reasons early detection of ventriculomegaly has become an important task. In order to identify ventriculomegaly from neonatal brain ultrasound images, we propose an automated image processing based approach that measures the anterior horn width as the distance between medial wall and floor of the lateral ventricle at the widest point. Measurement is done in the plane of the scan at the level of the intraventricular foramina. Our study is based on neonatal brain ultrasound images in the midline coronal view. In addition to ventriculomegaly detection, this work also includes both cross sectional and longitudinal study of anterior horn width of lateral ventricles. Experiments were carried out on brain ultrasound images of 96 neonates with gestational age ranging from 26 to 39 weeks and results have been verified with the ground truth provided by doctors. Accuracy of the proposed scheme is quite promising.
Similar content being viewed by others
References
Cheng, H. D., Shan, J., Ju, W., Guo, Y., and Zhang, L., Automated breast cancer detection and classification using ultrasound images: A survey. Pattern Recogn. 43(1):299–317, 2010.
Mondal, P., Mukhopadhyay, J., Sural, S., Majumdar, A. K., Biswas, A., Singh, A., and Mukherjee, S., A user interactive method for measuring lateral ventricle width in neonates. International Conference on Systems in Medicine and Biology, pp. 315–319, 2010.
Institute of Post Graduate Medical Education & Research and Seth Sukhlal Karnani Memorial Hospital. www.ipgmer.gov.in.
Thangavel, K., Manavalan, R., and Aroquiaraj, I. L., Removal of speckle noise from ultrasound medical image based on special filters: comparative study. Intl. Jrnl. Grap. Vis. Imag. Process. 9(3):25–32, 2009.
Rennie, J. M., Hagmann, C. F., and Robertson, N. J., Neonatal cerebral investigation, 2nd edn. Cambridge University Press, 2008.
Noble, J. A., and Boukerroui, D., Ultrasound image segmentation: A survey. IEEE Trans. Med. Imag. 25(8):987–1010, 2006.
Wells, P. N. T., Ultrasound imaging. Phys. Med. Biol. 51:R83–R98, 2006.
Portilla, J., Strela, V., Wainwright, M. J., and Simoncelli, E. P., Image denoising using scale mixtures of Gaussians in the wavelet domain. IEEE Trans. Image Process. 12(11):1338–1351, 2003.
Davies, M. W., Swaminathan, M., Chuang, S. L., and Betheras, F. R., Reference ranges for the linear dimensions of the intracranial ventricles in preterm neonates. Arch. Dis. Child., Fetal Neonatal Ed. 82:218–223, 2000.
Fitzgibbon, A., Pilu, M., and Fisher, R. B., Direct least square fitting of ellipses. IEEE Trans. Pattern Anal. Mach. Intell. 21(5):476–480, 1999.
Kuan, D. T., Sawchuk, A. A., Strand, T. C., and Chavel, P., Adaptive noise smoothing filter for images with signal-dependent noise. IEEE Trans. Pattern Anal. Mach. Intell. 7(2):165–177, 1985.
Hirashima, Y., Shindo, K., and Endo, S., Measurement of the area of the anterior horn of the right lateral ventricle for the diagnosis of brain atrophy by CT. Neuroradiology 25:23–27, 1983.
Levene, M. I., Measurement of the growth of the lateral ventricles in preterm Infants with real-time ultrasound. Arch. Dis. Child. 56:900–904, 1981.
Lee, J., Image enhancement and noise filtering by use of local statistics. IEEE Trans. Pattern Anal. Mach. Intell. 2(2):165–168, 1980.
Acknowledgements
The authors wish to thank all the members of the Department of Neonatology, IPGME & R and SSKM Hospital, Kolkata, India, for their support during data collection and analysis.
Author information
Authors and Affiliations
Corresponding author
Additional information
This research was supported by Ministry of Communication and Information Technology under Approval No. 1(23)/2006-ME & TMD (11-12-2006), Department of Information Technology, Govt. of India.
Rights and permissions
About this article
Cite this article
Mondal, P., Mukhopadhyay, J., Sural, S. et al. A Robust Method for Ventriculomegaly Detection from Neonatal Brain Ultrasound Images. J Med Syst 36, 2817–2828 (2012). https://doi.org/10.1007/s10916-011-9760-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10916-011-9760-8