Abstract
Extra-cellular neuro-recording signals used for functional mapping in deep brain stimulation (DBS) surgery and invasive brain computer interfaces, may suffer from poor signal to noise ratio. Therefore, a reliable automatic noise estimate is essential to extract spikes from recordings. We show that current methods are biased toward overestimation of noise-levels with increasing neuronal activity or artifacts. An improved and novel method is proposed that is based on an estimate of the mode of the distribution of the signal envelope. Our method makes use of the inherent characteristics of the noise distribution. For band-limited Gaussian noise the envelope of the signal is known to follow the Rayleigh distribution. The location of the peak of this distribution provides a reliable noise-level estimate. It is demonstrated that this new ‘envelope’ method gives superior performance both on simulated data, and on actual micro-electrode recordings made during the implantation surgery of DBS electrodes for the treatment of Parkinson’s disease.
Similar content being viewed by others
References
Abeles M, Goldstein MH (1977) Multi-spike train analysis. Proc IEEE 65:762–773. doi:10.1109/PROC.1977.10559
Amirnovin R, Williams ZM, Cosgrove GR, Eskandar EN (2006) Experience with microelectrode guided subthalamic nucleus deep brain stimulation. Neurosurgery 58:96–102. doi:10.1227/01.NEU.0000192690.45680.C2
Benabid AL, Krack PP, Benazzouz A, Limousin P, Koudsie A, Pollak P (2000) Deep brain stimulation of the subthalamic nucleus for Parkinson’s disease: methodologic aspects and clinical criteria. Neurology 55:S40–S44
Benazzouz A, Breit S, Koudsie A, Pollak P, Krack P, Benabid AL (2002) Intraoperative microrecordings of the subthalamic nucleus in Parkinson’s disease. Mov Disord 17:S145–S149. doi:10.1002/mds.10156
Donoho DL, Johnstone IM (1992) Ideal spatial adaptation via wavelet shrinkage. Biometrika 81:425–455. doi:10.1093/biomet/81.3.425
Fang Z-S, Xie N (1995) An analysis of various methods for computing the envelope of a random signal. Appl Ocean Res 17:9–19. doi:10.1016/0141-1187(94)00024-H
Israel Z, Schulder M (2004) History of electrophysiological recording for functional neurosurgery. Thieme Medical Publishers Inc, New York
Lozano AM, Hutchison WD, Dostrovsky JO (1995) Microelectrode monitoring of cortical and subcortical structures during stereotactic surgery. Acta Neurochir Suppl (Wien) 64:30–34
Moffitt MA, McIntyre CC (2005) Cortical recording with silicon microelectrodes: model-based analysis of contact dimension and encapsulation changes on recorded waveforms. In: Proceedings of 2005 2nd international IEEE/EMBS conference on neural engineering, IEEE, Arlington, pp 149–150
Moran A, Bar-Gad I, Bergman H, Israel Z (2006) Real-time refinement of subthalamic nucleus targeting using Bayesian decision-making on the root mean square measure. Mov Disord 21:1425–1431. doi:10.1002/mds.20995
Mrakic-Sposta S, Marceglia S, Egidi M, Carrabba G, Rampini P, Locatelli M, Foffania G, Accolla E, Cogiamanian F, Tarrima F, Barbieri S, Priori A (2008) Extracellular spike microrecordings from the subthalamic area in Parkinson’s disease. J Clin Neurosci 15:559–567. doi:10.1016/j.jocn.2007.02.091
Novak P, Daniluk S, Ellias SA, Nazzaro JM (2007) Detection of the subthalamic nucleus in microelectrographic recordings in Parkinson disease using the high-frequency (>500 Hz) neuronal background. J Neurosurg 106:175–179. doi:10.3171/jns.2007.106.1.175
Pancrazio JJ, Gray SA, Shubin YS, Kulagina N, Cuttino DS, Shaffer KM, Eisemann K, Curran A, Zim B, Gross GW (2003) A portable microelectrode array recording system incorporating cultured neuronal networks for neurotoxin detection. Biosens Bioelectron 18:1339–1347. doi:10.1016/S0956-5663(03)00092-7
Papoulis A (1984) Probability, random variables, and stochastic processes, 2nd edn. McGraw-Hill, New York
Proakis JG (1983) Digital communications. McGraw-Hill, New York, pp 607–608
Quiroga RQ, Nadasdy Z, Ben-Shaul Y (2004) Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering. Neural Comput 16:1661–1687. doi:10.1162/089976604774201631
Santiago RA, McNames J, Falkenberg H, Burchiel K (2002) Automatic target localization using microelectrode recordings. In: Conference proceedings. Second joint EMBS-BMES conference 2002 24th annual international conference of the engineering in medicine and biology society. Annual fall meeting of the biomedical engineering society, vol 41, IEEE, Houston, pp 42–43
Starr PA (2002) Placement of deep brain stimulators into the subthalamic nucleus or Globus pallidus internus: technical approach. Stereotact Funct Neurosurg 79:118–145. doi:10.1159/000070828
Watkins PT, Santhanam G, Shenoy KV, Harrison RR (2004) Validation of adaptive threshold spike detector for neural recording. In: Proceedings of the 26th annual international conference of the IEEE EMBS’04, San Francisco
Acknowledgments
K. Dolan and H.C.F. Martens gratefully acknowledge the support of the BrainGain Smart Mix Programme of the Netherlands Ministry of Economic Affairs and the Netherlands Ministry of Education, Culture, and Science.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Dolan, K., Martens, H.C.F., Schuurman, P.R. et al. Automatic noise-level detection for extra-cellular micro-electrode recordings. Med Biol Eng Comput 47, 791–800 (2009). https://doi.org/10.1007/s11517-009-0494-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-009-0494-4