Abstract
Histological examinations typically require the excision of tissue, followed by its fixation, slicing, staining, mounting and imaging, with timeframes ranging from minutes to days. This process may remove functional tissue, may miss abnormalities through under-sampling, prevents rapid decision-making, and increases costs. Here, we report the feasibility of microscopes based on swept confocally aligned planar excitation technology for the volumetric histological imaging of intact living tissue in real time. The systemsâ single-objective, light-sheet geometry and 3D imaging speeds enable roving image acquisition, which combined with 3D stitching permits the contiguous analysis of large tissue areas, as well as the dynamic assessment of tissue perfusion and function. Implemented in benchtop and miniaturized form factors, the microscopes also have high sensitivity, even for weak intrinsic fluorescence, allowing for the label-free imaging of diagnostically relevant histoarchitectural structures, as we show for pancreatic disease in living mice, for chronic kidney disease in fresh human kidney tissues, and for oral mucosa in a healthy volunteer. Miniaturized high-speed light-sheet microscopes for in-situ volumetric histological imaging may facilitate the point-of-care detection of diverse cellular-level biomarkers.
This is a preview of subscription content, access via your institution
Access options
Access Nature and 54 other Nature Portfolio journals
Get Nature+, our best-value online-access subscription
$29.99 /Â 30Â days
cancel any time
Subscribe to this journal
Receive 12 digital issues and online access to articles
$119.00 per year
only $9.92 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout







Similar content being viewed by others
Data availability
The main data supporting the results in this study are available within the paper and its Supplementary Information. The raw and analysed datasets generated during the study are too large to be publicly shared, yet they are available for research purposes from the corresponding authors on reasonable request.
Code availability
All custom MATLAB and ImageJ scripts used to process and stitch data are available from the authors upon request. Pairwise stitching code for stitching roving scans in ImageJ is available on the Hillman Lab GitHub github.com/hillmanlab/mediSCAPE_stitching.
References
Biopsy Devices - Global Analysis and Market Forecasts. 66 (GlobalData MediPoint, 2016).
Jaafar, H. Intra-operative frozen section consultation: concepts, applications and limitations. Malays. J. Med. Sci. 13, 4â12 (2006).
Vieth, M., Ell, C., Gossner, L., May, A. & Stolte, M. Histological analysis of endoscopic resection specimens from 326 patients with Barrettâs esophagus and early neoplasia. Endoscopy 36, 776â781 (2004).
Wang, T. D. et al. Functional imaging of colonic mucosa with a fibered confocal microscope for real-time in vivo pathology. Clin. Gastroenterol. Hepatol. 5, 1300â1305 (2007).
Goetz, M. & Kiesslich, R. Advances of endomicroscopy for gastrointestinal physiology and diseases. Am. J. Physiol. Gastrointest. Liver Physiol. 298, G797âG806 (2010).
van Dam, G. M. et al. Intraoperative tumour-specific fluorescence imaging in ovarian cancer by folate receptor-alpha targeting: first in-human results. Nat. Med. 17, 1315â1319 (2011).
Hsiung, P. L. et al. Detection of colonic dysplasia in vivo using a targeted heptapeptide and confocal microendoscopy. Nat. Med. 14, 454â458 (2008).
Sun, Y. et al. Endoscopic fluorescence lifetime imaging for in vivo intraoperative diagnosis of oral carcinoma. Microsc. Microanal. 19, 791â798 (2013).
Saar, B. G. et al. Video-rate molecular imaging in vivo with stimulated Raman scattering. Science 330, 1368â1370 (2010).
Grosberg, L. E., Radosevich, A. J., Asfaha, S., Wang, T. C. & Hillman, E. M. Spectral characterization and unmixing of intrinsic contrast in intact normal and diseased gastric tissues using hyperspectral two-photon microscopy. PLoS ONE 6, e19925 (2011).
You, S. et al. Intravital imaging by simultaneous label-free autofluorescence-multiharmonic microscopy. Nat. Commun. 9, 2125 (2018).
Orringer, D. A. et al. Rapid intraoperative histology of unprocessed surgical specimens via fibre-laser-based stimulated Raman scattering microscopy. Nat. Biomed. Eng. https://doi.org/10.1038/s41551-016-0027 (2017).
Hollon, T. C. et al. Near real-time intraoperative brain tumour diagnosis using stimulated Raman histology and deep neural networks. Nat. Med. 26, 52â58 (2020).
Konig, K. et al. Clinical two-photon microendoscopy. Microsc. Res. Tech. 70, 398â402 (2007).
Bouchard, M. B. et al. Swept confocally-aligned planar excitation (SCAPE) microscopy for high speed volumetric imaging of behaving organisms. Nat. Photonics 9, 113â119 (2015).
Xu, L. et al. Widespread receptor-driven modulation in peripheral olfactory coding. Science https://doi.org/10.1126/science.aaz5390 (2020).
Voleti, V. et al. Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0. Nat. Methods 16, 1054â1062 (2019).
Vaadia, R. D. et al. Characterization of proprioceptive system dynamics in behaving Drosophila larvae using high-speed volumetric microscopy. Curr. Biol. 29, 935â944.e4 (2019).
Hillman, E. M. et al. High-speed 3D imaging of cellular activity in the brain using axially-extended beams and light sheets. Curr. Opin. Neurobiol. 50, 190â200 (2018).
Yin, C. et al. Miniature in vivo MEMS-based line-scanned dual-axis confocal microscope for point-of-care pathology. Biomed. Opt. Express 7, 251â263 (2016).
Liu, J. T. et al. Point-of-care pathology with miniature microscopes. Anal. Cell Pathol. 34, 81â98 (2011).
Flusberg, B. A. et al. Fiber-optic fluorescence imaging. Nat. Methods 2, 941â950 (2005).
Husain, S. A. et al. Reproducibility of deceased donor kidney procurement biopsies. Clin. J. Am. Soc. Nephrol. 15, 257â264 (2020).
Deal, J. et al. Identifying molecular contributors to autofluorescence of neoplastic and normal colon sections using excitation-scanning hyperspectral imaging. J. Biomed. Opt. 24, 1â11 (2018).
Pavlova, I., Williams, M., El-Naggar, A., Richards-Kortum, R. & Gillenwater, A. Understanding the biological basis of autofluorescence imaging for oral cancer detection: high-resolution fluorescence microscopy in viable tissue. Clin. Cancer Res. 14, 2396â2404 (2008).
Hu, W. Y. & Fu, L. Simultaneous characterization of pancreatic stellate cells and other pancreatic components within three-dimensional tissue environment during chronic pancreatitis. J. Biomed. Opt. https://doi.org/10.1117/1.Jbo.18.5.056002 (2013).
Hingorani, S. R. et al. Trp53R172H and KrasG12D cooperate to promote chromosomal instability and widely metastatic pancreatic ductal adenocarcinoma in mice. Cancer Cell 7, 469â483 (2005).
Preibisch, S., Saalfeld, S. & Tomancak, P. Globally optimal stitching of tiled 3D microscopic image acquisitions. Bioinformatics 25, 1463â1465 (2009).
Siegel, R. L., Miller, K. D., Fuchs, H. E. & Jemal, A. Cancer statistics, 2021. CA Cancer J. Clin. 71, 7â33 (2021).
Thekkek, N. et al. Vital-dye enhanced fluorescence imaging of GI mucosa: metaplasia, neoplasia, inflammation. Gastrointest. Endosc. 75, 877â887 (2012).
Giacomelli, M. G. et al. Virtual hematoxylin and eosin transillumination microscopy using epi-fluorescence imaging. PLoS ONE 11, e0159337 (2016).
Skala, M. C. et al. In vivo multiphoton microscopy of NADH and FAD redox states, fluorescence lifetimes, and cellular morphology in precancerous epithelia. Proc. Natl Acad. Sci. USA 104, 19494â19499 (2007).
Liang, W., Hall, G., Messerschmidt, B., Li, M. J. & Li, X. Nonlinear optical endomicroscopy for label-free functional histology in vivo. Light Sci. Appl. https://doi.org/10.1038/lsa.2017.82 (2017).
Drezek, R. et al. Autofluorescence microscopy of fresh cervical-tissue sections reveals alterations in tissue biochemistry with dysplasia. Photochem. Photobiol. 73, 636â641 (2001).
Neira, J. A. et al. Aggressive resection at the infiltrative margins of glioblastoma facilitated by intraoperative fluorescein guidance. J. Neurosurg. 127, 111â122 (2017).
Miller, S. E. et al. First-in-human intraoperative near-infrared fluorescence imaging of glioblastoma using cetuximab-IRDye800. J. Neurooncol. 139, 135â143 (2018).
Abeytunge, S. et al. Confocal microscopy with strip mosaicing for rapid imaging over large areas of excised tissue. J. Biomed. Opt. 18, 61227 (2013).
Giacomelli, M. G. et al. Comparison of nonlinear microscopy and frozen section histology for imaging of Mohs surgical margins. Biomed. Opt. Express 10, 4249â4260 (2019).
Fereidouni, F. et al. Microscopy with ultraviolet surface excitation for rapid slide-free histology. Nat. Biomed. Eng. 1, 957â966 (2017).
Barner, L. A., Glaser, A. K., Huang, H., True, L. D. & Liu, J. T. C. Multi-resolution open-top light-sheet microscopy to enable efficient 3D pathology workflows. Biomed. Opt. Express 11, 6605â6619 (2020).
Glaser, A. K. et al. Light-sheet microscopy for slide-free non-destructive pathology of large clinical specimens. Nat. Biomed. Eng. https://doi.org/10.1038/s41551-017-0084 (2017).
Abadie, S. et al. 3D imaging of cleared human skin biopsies using light-sheet microscopy: a new way to visualize in-depth skin structure. Skin Res. Technol. 24, 294â303 (2018).
Noe, M. et al. Immunolabeling of cleared human pancreata provides insights into three-dimensional pancreatic anatomy and pathology. Am. J. Pathol. 188, 1530â1535 (2018).
Hillman, E. M. & Moore, A. All-optical anatomical co-registration for molecular imaging of small animals using dynamic contrast. Nat. Photonics 1, 526â530 (2007).
Xing, J. Liu S. and Zhao, W. FPGA-accelerated real-time volume rendering for 3D medical image. 2010 3rd International Conference on Biomedical Engineering and Informatics https://doi.org/10.1109/BMEI.2010.5639475 (2010).
Jin, K., Lee, K. & Kim, G. in 3rd IEEE International Conference on Computer and Communications (ICCC) 2085â2088 (2017).
Rivenson, Y. et al. Virtual histological staining of unlabelled tissue-autofluorescence images via deep learning. Nat. Biomed. Eng. 3, 466â477 (2019).
Kester, R. T., Tkaczyk, T. S., Descour, M. R., Christenson, T. & Richards-Kortum, R. High numerical aperture microendoscope objective for a fibre confocal reflectance microscope. Opt. Express 15, 2409â2420 (2007).
Barretto, R. P., Messerschmidt, B. & Schnitzer, M. J. In vivo fluorescence imaging with high-resolution microlenses. Nat. Methods 6, 511â512 (2009).
McCaslin, A. F., Chen, B. R., Radosevich, A. J., Cauli, B. & Hillman, E. M. In vivo 3D morphology of astrocyte-vasculature interactions in the somatosensory cortex: implications for neurovascular coupling. J. Cereb. Blood Flow Metab. 31, 795â806 (2011).
Preibisch, S., Saalfeld, S. & Tomancak, P. Globally optimal stitching of tiled 3D microscopic image acquisitions. Bioinformatics 25, 1463â1465 (2009).
Schindelin, J. et al. Fiji: an open-source platform for biological-image analysis. Nat. Methods 9, 676â682 (2012).
Horl, D. et al. BigStitcher: reconstructing high-resolution image datasets of cleared and expanded samples. Nat. Methods 16, 870â874 (2019).
Acknowledgements
We thank L. Hammond and D. Peterka at the Zuckerman Instituteâs Cellular Imaging platform for help with confocal and slide imaging; the Histology Core facility services within the Molecular Pathology Shared Resource (CUMC Herbert Irving Comprehensive Cancer Center) for processing all histological samples; H. Remotti (Columbia) and J. Poneros (Columbia) for their support and valuable insights on possible application spaces; S. Sastra and C. Palermo (Columbia) for assistance with mouse pancreas experiments; M. Hortsch (University of Michigan Medical School) for sharing high-quality histology images of human tissues on their Virtual Microscopy Database (under CC BY-SA-NC); C. Kim and S. Kim for assistance with mouse work, and other members of the Hillman laboratory for their support and assistance, including H. Yu, W. Yan, M. Shaik, H. Yu, L. Grosberg and K. Stewart. Funding for this work was provided by the Columbia-Coulter Translational Research Partnership (37) and the Coulter Foundation Early Career programme to E.M.C.H.; the National Institutes of Health BRAIN initiative grants U01NS09429, UF1NS108213 to E.M.C.H. and U19NS104649 to R. Costa; NCI grant U01CA236554 to E.M.C.H. and D. Brenner; the National Science Foundation NSF-GRFP DGE - 1644869 to K.B.P., IGERT 0801530 to V.V. and CAREER CBET-0954796 to E.M.C.H.; the Simons Foundation Collaboration on the Global Brain 542951 to E.M.C.H.; the Department of Defense MURI W911NF-12-1-0594 to E.M.C.H.; and the Kavli Institute for Brain Science to E.M.C.H.
Author information
Authors and Affiliations
Contributions
E.M.C.H. and K.B.P. conceived the use of MediSCAPE for clinical applications, planned experiments, analysed and discussed results. K.B.P., V.V. and E.M.C.H. designed and built the primary MediSCAPE system used in these studies, while the miniature MediSCAPE system was designed and built by W. Liang, M.J.C., K.B.P. and E.M.C.H. In vivo and fresh mouse tissue experiments were performed by K.B.P., M.J.C., W. Liang, W. Li, C.P.-C. and G.S.L., with assistance from H.T.Z. and Al.J.Y. Mouse pancreatic cancer models were provided by K.P.O. and imaged by K.B.P., Al.J.Y. and W. Liang. Human in vivo imaging was performed by M.J.C., W.Liang, W. Li, K.P.B. and E.M.C.H. Human tissue sample access, including regulatory documentation, was managed by S.M.C., who also provided extensive review of imaging data, histopathology and clinical interpretation of kidney and related images with K.B.P. K.P.O. provided extensive review and consultation on image interpretation for the pancreatic cancer data; An.J.Y. and E.P. provided consultation and review of human oral mucosa imaging. J.M.L. assisted with stitching stage-scans. Image analysis, stitching, rendering, figure and movie preparation were performed by K.B.P. and M.J.C. Manuscript was prepared and reviewed by K.B.P., E.M.C.H., S.M.C. and W. Liang.
Corresponding author
Ethics declarations
Competing interests
Columbia University holds intellectual property rights on SCAPE and MediSCAPE, some of which are licensed to Leica Microsystems. E.M.C.H., K.B.P., V.V., W. Li, W. Liang, G. S. Lee and C.P.C. could financially benefit from the commercial development of MediSCAPE. The other authors declare no competing interests.
Peer review
Peer review information
Nature Biomedical Engineering thanks Ralf Bauer, Matthias Gunzer and the other, anonymous, reviewer(s) for their contribution to the peer review of this work.
Additional information
Publisherâs note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data
Extended Data Fig. 1 Dual colour autofluorescence visualization.
xy image planes acquired by MediSCAPE in fresh mouse brain cortex, including a prominent blood vessel. Contrast corresponds to autofluorescence excited by 488ânm light. Dual colour emission images are acquired simultaneously using an image splitter in front of the camera and positioning each colour channels side-by-side on the camera chip (along y). a and b show grayscale raw emission channels acquired with 525/50ânm and 618/50ânm bandpass filters respectively. These channels are converted to c, âyellow hotâ and d, blue colormaps and then merged, as shown in e. This colour-scheme was chosen to enable the highly overlapping colour channels to be more easily distinguished when merged than conventional RBG scaling, while also being more colour-blind accessible. Scale bars, 100âµm.
Extended Data Fig. 2 Label-free imaging of fresh mouse tissue with miniaturized MediSCAPE.
xy (top) and yz (bottom) cross-sections in various fresh mouse tissue acquired with the miniaturized MediSCAPE system with 488ânm excitation and dual colour emission channels labelled as shown. Cross- sections show a, tubules in the kidney cortex, b, capsule and underlying cords of hepatocytes in the liver, c, cardiac muscle in the heart and d, crypts of Lieberkühn in the colon mucosa. White dotted lines in the xy planes indicate the location of corresponding yz planes shown. e. 3D rendering (Imaris) of a stitched field of view created from 16âseconds of continuous volume acquisition at 11.2 VPS while roving across the colon mucosa. Insets to the right show single planes from the ROI indicated (yellow dotted box). Yellow dotted lines in the xy cross-section show the locations of corresponding depth cross- sections. Only emission at ~525ânm is shown here, in grayscale. All scale bars, 100âµm.
Extended Data Fig. 3 Autofluorescence in diabetic human kidney tissue imaged with MediSCAPE.
Autofluorescence captured by MediSCAPE reveals features common to and beyond those seen on routine histology. a, PAS histology image of kidney cortex tissue from an older, diabetic patient with features of mild diabetic nephropathy. Scale bar, 200âµm. b, a MediSCAPE xy slice from a stage-scanned volume of the same piece of tissue (while fresh) showing autofluorescence excited at 488ânm. Yellow arrows point to the kidney capsule, white arrows indicate urinary casts, seen in both SCAPE and PAS images. Dotted line squares indicate regions of interest shown in more detail in c, highlighting features more evident by SCAPE than PAS histology. Scale bar, 200âµm. c(i), A focal subcapsular collection of tubules with autofluorescent cytoplasmic granules (teal arrow). Urinary cast material (white arrows) is also evident in the xy plane, and further evidenced by characteristically strong autofluorescence in the yz plane. c(ii). Tubules with accentuated peritubular autofluorescence (red arrow). c(iii) Glomerulus with focal autofluorescent granules. Scale bars, 50âµm.
Extended Data Fig. 4 MediSCAPE label-free imaging of elastic fibres and fat cells in human perirenal fat.
a, 3D rendering (ImageJ 3DViewer) of a section of normal human perirenal fat showing highly fluorescent elastic fibres and fat cells. b, a yz cross-section from the plane indicated shows layering of fibres over fat cells, which can be distinguished as circular yellow droplets. c, lateral cross-sections with corresponding tissue depth indicated on the bottom left corner. Fat cells are indicated with red arrows and intersecting vessels also labelled. All scale bars, 100âµm.
Extended Data Fig. 5 MediSCAPE images of proflavine-stained fresh human kidney biopsy including pseudocolour H&E.
a, xy slice in a stage-scanned field of view showing proflavine, a nuclear dye (green), and red autofluorescence emission (blue), both acquired simultaneously with 488ânm excitation. Autofluorescence is shown on a log scale for better visualization. b, Pseudocolored xy slice from panel a, approximating H&E histology with proflavine shown in purple and autofluorescence shown in pink. c, Inset showing a glomerulus (white arrow) and tubules in greater detail with true H&E histology of an adjacent region shown in d for comparison. See Supplementary Movie 10 for a depth fly-through. All scale bars, 100âµm.
Extended Data Fig. 6 Stained human kidney tissues imaged with MediSCAPE.
Fresh human kidney tissues showing features of arterionephrosclerosis were stained with nuclear dye, either b, 1% methylene blue (exc. 637ânm, em. >685ânm) or d-k, 0.01% proflavine (exc. 488ânm, em. 525/50ânm). imaged by MediSCAPE, then processed for histology where the same tissue block faces were stained with PAS and/or H&E. a-c, demonstrate how the 4 main renal histologic components which must be routinely evaluated with both PAS and H&E histology appear in a, PAS histology, b, an xy slice of a MediSCAPE volume stained with methylene blue and c, H&E histology. These components are indicated as following: glomeruli (white arrows), arteries (red arrows), tubules (black arrows), and interstitium (blue arrows). Methylene blue in the MediSCAPE image defines cellular cytoplasmic, nuclear and extracellular compartments, similar to H&E but better highlights arterial elastic lamina and tubular and interstitial compartments, similar to PAS histologic sections. A second biopsy piece from the same patient shows scarred tubulointerstitium in a focal area of fibrosis (green arrows) in both d, MediSCAPE and e, corresponding H&E histology. f, a 3D rendering (Imaris) of the larger stage-scanned volume acquired on MediSCAPE, shows the 3D structure of fibrosis (green arrow), arteries and glomeruli (white arrows). The lengthwise white dotted line indicates the origin of the xz depth section shown in g. h, A non-sclerotic glomerulus is shown in more detail across 20um in depth. See Supplementary Movie 11 for a moving 3D render and depth fly-throughs of lateral and depth cross-sections of the full 3D volume. A second region of the same tissue shows i, globally- sclerotic glomeruli (yellow arrows) and urinary casts (light blue arrow) in a xy slice and depth slice taken at the white dotted line. j, H&E histology of a deeper section of the same region and k, MediSCAPE xy cross-section of the entire stage-scanned volume also shows globally-sclerotic glomeruli (yellow arrows) and normal glomeruli (white arrows). All scale bars, 100âµm.
Extended Data Fig. 7 Comparison of topical dyes applied to fresh mouse colon mucosa.
Single xy (top) and yz (bottom) slices in samples of fresh mouse colon mucosa imaged with MediSCAPE. Contrast is derived from a, 0.01% proflavine, a nuclear dye (exc. 488ânm, em. 525/50ânm), b, 1% methylene blue, a clinically-used nuclear dye (exc. 637ânm, em. >685ânm), and c, fluorescein sodium, an FDA-approved topical and IV dye (exc. 488ânm, em. 525/50ânm). Yellow dotted lines indicate locations of corresponding cross-sections and yellow arrows indicate nuclei in insets. Depth penetration of topically applied dyes is both stain- and tissue-dependent, as shown in yz depth sections. Also shown for comparison is d, autofluorescence (exc. 488ânm, em. 525/50ânm) imaged with MediSCAPE with e, corresponding en face and depth-sectioned H&E histology of a similar region in the same colon tissue. White arrows, crypts of Lieberkühn. Red arrows, goblet cells. Scale bars 100âµm.
Supplementary information
Supplementary Information
Supplementary Notes 1 and 2, Movies 1â18, Tables 1 and 2, and References.
Supplementary Movie 1
Fresh mouse kidney imaged with low and high magnification on MediSCAPE.
Supplementary Movie 2
Autofluorescence in fresh mouse heart, brain, lung and liver imaged with MediSCAPE.
Supplementary Movie 3
Autofluorescence in fresh mouse spleen, bladder, muscle and colon imaged with MediSCAPE.
Supplementary Movie 4
Autofluorescence in normal pancreas and pancreatic ductal adenocarcinoma (PDA) imaged with MediSCAPE.
Supplementary Movie 5
Fresh mouse kidney, liver, heart and colon imaged with a miniaturized version of MediSCAPE.
Supplementary Movie 6
Label-free in vivo mouse kidney imaged with MediSCAPE at 9.3âVPS.
Supplementary Movie 7
Stitched roving scan of in vivo label-free pancreatic tissue in a mouse model of pancreatic ductal adenocarcinoma (PDA) imaged with MediSCAPE.
Supplementary Movie 8
Label-free MediSCAPE imaging of in vivo mouse heart imaged at 12.9âVPS.
Supplementary Movie 9
MediSCAPE autofluorescence image of fresh human kidney biopsy with chronic kidney disease.
Supplementary Movie 10
3D H&E pseudocolour MediSCAPE image stack of fresh normal human kidney tissue stained with proflavine.
Supplementary Movie 11
A 3D rendering and flythrough of proflavine-stained human kidney tissue imaged with MediSCAPE.
Supplementary Movie 12
3D rendering of MediSCAPE roving data acquired in vivo on the human tongue.
Supplementary Movie 13
3D rendering of stitched MediSCAPE roving data acquired in vivo on the human tongue.
Supplementary Movie 14
3D rendering of MediSCAPE roving data acquired in vivo on the human lip.
Supplementary Movie 15
Depth flythrough of mini-MediSCAPE roving data acquired in vivo on the human tongue and inner lip.
Supplementary Movie 16
Roving MediSCAPE imaging of in vivo mouse brain vasculature with IV FITC-dextran.
Supplementary Movie 17
In vivo time lapse of ischaemia-reperfusion in mouse kidney acquired with MediSCAPE.
Supplementary Movie 18
In vivo imaging of FNa infusion in mouse kidney in real-time with MediSCAPE.
Rights and permissions
About this article
Cite this article
Patel, K.B., Liang, W., Casper, M.J. et al. High-speed light-sheet microscopy for the in-situ acquisition of volumetric histological images of living tissue. Nat. Biomed. Eng 6, 569â583 (2022). https://doi.org/10.1038/s41551-022-00849-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41551-022-00849-7