Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
  • Rapid Communication

Effect of fractional blood flow on plasma skimming in the microvasculature

Jiho Yang, Sung Sic Yoo, and Tae-Rin Lee
Phys. Rev. E 95, 040401(R) – Published 25 April 2017

Abstract

Although redistribution of red blood cells at bifurcated vessels is highly dependent on flow rate, it is still challenging to quantitatively express the dependence of flow rate in plasma skimming due to nonlinear cellular interactions. We suggest a plasma skimming model that can involve the effect of fractional blood flow at each bifurcation point. To validate the model, it is compared with in vivo data at single bifurcation points, as well as microvascular network systems. In the simulation results, the exponential decay of the plasma skimming parameter M along fractional flow rate shows the best performance in both cases.

  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Received 25 January 2017

DOI:https://doi.org/10.1103/PhysRevE.95.040401

©2017 American Physical Society

Physics Subject Headings (PhySH)

Fluid DynamicsPhysics of Living Systems

Authors & Affiliations

Jiho Yang1,2, Sung Sic Yoo1, and Tae-Rin Lee1,*

  • 1Advanced Institutes of Convergence Technology, Seoul National University, Suwon 443-270, Republic of Korea
  • 2Department of Computer Science, Technische Universität München, Boltzmannstraße 3, Garching, Germany

  • *Corresponding author: taerinlee@snu.ac.kr

Article Text (Subscription Required)

Click to Expand

References (Subscription Required)

Click to Expand
Issue

Vol. 95, Iss. 4 — April 2017

Reuse & Permissions
Access Options
Author publication services for translation and copyediting assistance advertisement

Authorization Required


×

Images

  • Figure 1
    Figure 1

    Plots of plasma skimming parameter M against fractional blood flow and illustrations of RBC redistribution in two cases. Here Q1/Q0 denotes the fractional blood flow between the largest daughter vessel and parent vessel. (a)–(c) Without using the fractional blood flow model, there is negligible change in RBC redistributions at bifurcation since M is set as a constant. (d)–(f) When including the effect of fractional blood flow, both hemoconcentration and hemodilution after plasma skimming become more significant.

    Reuse & Permissions
  • Figure 2
    Figure 2

    Ratio of hematocrit between parent and daughter vessels (Hi/H0) against fractional blood flow (Qi/Q0) at single bifurcation for comparing fractional blood flow model with the model developed by Gould and Linninger [26] and experimental data [24]. Two cases of geometries stated in Table 1 are considered. Significant amplifications in both hemoconcentration and hemodilution are produced by using fractional blood flow model, accurately matching the experimental data.

    Reuse & Permissions
  • Figure 3
    Figure 3

    Ratio of hematocrit between parent and daughter vessels (Hi/H0) against fractional blood flow (Qi/Q0) at a single bifurcation for different k values. The second case stated in Table 1 is considered. The plots clearly show the high sensitivity of k and that k=4 gives the best match with the experimental data [24].

    Reuse & Permissions
  • Figure 4
    Figure 4

    Computational model of the microvascular network and the corresponding hemodynamic calculations.

    Reuse & Permissions
  • Figure 5
    Figure 5

    Comparison of hemodynamic characteristics at the microvascular network level between (a)–(c) Gould and Linninger's model and (d)–(f) the fractional flow model. Vessel diameters are asymmetrically decreased from 40 to 6μm. The pressure drop between the root vessel to capillary ends is set to 47 mm Hg. Flow velocity and pressure data are compared with two sets of in vivo experimental data [34, 35]. Also shown is the relative hematocrit distribution along with vessel diameters for the microvascular network model. The systemic hematocrit Hsys is set to 0.45. Black triangles represent in vivo experimental data [36]. The initial hematocrit at the root vessel is varied from 0.3 to 0.45.

    Reuse & Permissions
×

Sign up to receive regular email alerts from Physical Review E

Log In

Cancel
×

Search


Article Lookup

Paste a citation or DOI

Enter a citation
×