Abstract
A combination technique of some kinds of enzymatic reactions for flow injection analysis with an immobilized enzyme-reactor column was studied. This system consisted of hand-made reactor columns packed with glucose oxidase and horseradish peroxidase immobilized onto chitosan beads, and a fluorometric detector. It was applied for the determination of glucose in some beverages, Japanese Sake and liquor samples. Under the recommended conditions, it could determine a sample within 10 min. The calibration curve for glucose was linear from 20.0 mg dm–3 to 0.5 mg dm–3 in the low-sensitivity region of the detector, and from 0.5 mg dm–3 to 30 μg dm–3 in the high-sensitivity region of the detector. The detection limit (S/N=10) was 30 μg dm–3 as the concentration of glucose, and 54 ng as its absolute amount. There was no interference from major substances present in either beverage or serum samples.
Similar content being viewed by others
References
S. Milardovic, I. Kruhak, D. Ivekovic, V. Rumenjak, M. Tkalcec, and B. S. Grabaric, Anal. Chim. Acta, 1997, 350, 91.
N. Kiba, A. Itagaki, S. Fukumura, K. Saegusa, and M. Furusawa, Anal. Chim. Acta.1997, 354, 205.
J. F. Sierra, J. Galban, S. de Marcos, and J. R. Castillo, Anal. Chim. Acta.1998, 368, 97.
M. Khayyami, G. Johansson, D. Kriz, B. Xie, P. O. Larsson, and B. Danielsson, Talanta.1996, 43, 957.
M. Abraham, J. Nemcsok, and B. Szujani, Intern. J. Anal. Chem. 1992, 50, 53.
L. Gorton and L. Ögren, Anal. Chim. Acta, 1981, 130, 45.
I. L. Mattos, J. M. Fernandez-Romero, M. D. Luque De Castro, and M. Valcárcel, Analyst, 1995, 120, 179.
H. Ukeda, M. Ohira, and M. Sawamura, Anal. Sci. 1999, 15, 447.
G. P. Avila, A. Salvador, and M. de la Guardia, Analyst, 1998, 123, 999.
A. Sakuragawa, T. Taniai, and T. Okutani, Anal. Chim. Acta, 1998, 374, 191.
T. Taniai, A. Sakuragawa, and T. Okutani, Anal. Sci, 1999, 15, 1077.
J. Pütter, “Method of Enzymatic Analysis”. ed. H. U. Bergmeryer, Vol. 2, 1974. Verlag Chemie, Weinheim/Academic Press, New York.
B. E. P. Swoboda and V. Massay, J. Biol. Chem. 1965, 240, 2209.
A. Krug, R. Göbel, and R. Kellner, Anal. Chim. Acta. 1994, 287, 59.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Taniai, T., Sakuragawa, A. & Okutani, T. Fluorometric Determination of Glucose by Flow Injection Analysis Using Immobilized Enzyme-Reactor Columns Prepared by Coupling Glucose Oxidase and Peroxidase onto Chitosan Beads. ANAL. SCI. 16, 517–521 (2000). https://doi.org/10.2116/analsci.16.517
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.16.517