Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Info: Zenodo’s user support line is staffed on regular business days between Dec 23 and Jan 5. Response times may be slightly longer than normal.

Published November 1, 2021 | Version v1
Dataset Open

Fabrication of a Soft Robotic Gripper With Integrated Strain Sensing Elements Using Multi-Material Additive Manufacturing

  • 1. Department of Functional Materials, Empa, Überlandstrasse 129, 8600 Dübendorf, Switzerland
  • 2. Brubotics, Vrije Universiteit Brussel (VUB) and Imec, Pleinlaan 2, B-1050 Brussels, Belgium

Description

With the purpose of making soft robotic structures with embedded sensors, additive manufacturing techniques like fused deposition modeling (FDM) are popular. Thermoplastic polyurethane (TPU) filaments, with and without conductive fillers, are now commercially available. However, conventional FDM still has some limitations because of the marginal compatibility with soft materials. Material selection criteria for the available material options for FDM have not been established. In this study, an open-source soft robotic gripper design has been used to evaluate the FDM printing of TPU structures with integrated strain sensing elements in order to provide some guidelines for the material selection when an elastomer and a soft piezoresistive sensor are combined. Such soft grippers, with integrated strain sensing elements, were successfully printed using a multi-material FDM 3D printer. Characterization of the integrated piezoresistive sensor function, using dynamic tensile testing, revealed that the sensors exhibited good linearity up to 30% strain, which was sufficient for the deformation range of the selected gripper structure. Grippers produced using four different TPU materials were used to investigate the effect of the Shore hardness of the TPU on the piezoresistive sensor properties. The results indicated that the in situ printed strain sensing elements on the soft gripper were able to detect the deformation of the structure when the tentacles of the gripper were open or closed. The sensor signal could differentiate between the picking of small or big objects and when an obstacle prevented the tentacles from opening. Interestingly, the sensors embedded in the tentacles exhibited good reproducibility and linearity, and the sensitivity of the sensor response changed with the Shore hardness of the gripper. Correlation between TPU Shore hardness, used for the gripper body and sensitivity of the integrated in situ strain sensing elements, showed that material selection affects the sensor signal significantly.

Files

Figure_2a.csv

Files (19.6 MB)

Name Size Download all
md5:e7ee99b37eed874be6d562b573030115
1.6 MB Preview Download
md5:893a3121e27cded764b1d907b9836723
81 Bytes Preview Download
md5:832f52c17fe113271d7d7f9762d6030b
6.0 kB Preview Download
md5:1cdd2f42f591746dd7824ffe1f7f81b2
781.4 kB Preview Download
md5:240435dbd8b4b6335d1d9ddd3b4a53e6
2.5 MB Preview Download
md5:52407f4692f923cf8477cda1fc51ffd1
9.8 kB Preview Download
md5:d84aaf3d4d9a484c47ef344dae2c3160
590.9 kB Preview Download
md5:304b04cacabaefb5709427c47e94bc43
53.2 kB Preview Download
md5:5f43b4cd3a804d840555caa84dc289b5
8.6 kB Preview Download
md5:05693637475bb4082698d3152abc534e
8.0 kB Preview Download
md5:0770467ed2ea4f9af337b365484bfc60
2.5 MB Preview Download
md5:5096f49380e55f9961b28dc52cb627db
7.1 MB Preview Download
md5:a285c0467717a026e7484a34de0b06e6
2.6 MB Preview Download
md5:2da226318a4f64d2201d85f1b17033bb
1.9 MB Preview Download

Additional details

Related works

Is source of
Journal article: 10.3389/frobt.2021.615991 (DOI)

Funding

SHERO – Self-HEaling soft RObotics 828818
European Commission