Reboiler E 304
Reboiler E 304
Reboiler E 304
Diseño de Plantas II
Parte 8
Reboliler E-304
𝐿𝑏
𝑉 18426,776
= ℎ
𝐿ℎ𝑎𝑧 𝑡𝑢𝑏𝑢𝑙𝑎𝑟 10 𝑝𝑖𝑒
𝑉 𝐿𝑏
= 1842,677
𝐿ℎ𝑎𝑧 𝑡𝑢𝑏𝑢𝑙𝑎𝑟 ℎ ∗ 𝑝𝑖𝑒
PRESSURE SPECIFICATION:
HOT SIDE PRESSURE SCALE FACTOR 1.0000 HOT SIDE MAX FRACTIONAL DP 0.4000
COLD SIDE PRESSURE SCALE FACTOR 1.0000 COLD SIDE MAX FRACTIONAL DP 0.4000
HEAT TRANSFER COEFFICIENT SPECIFICATION: HEAT TRANS. COEFF. SCALE FACTOR 1.0000
EQUIPMENT SPECIFICATIONS:
NUMBER OF SHELL PASSES 1 NUMBER OF TUBE PASSES 2
TEMA SHELL TYPE E ORIENTATION HORIZONTAL
BAFFLE TYPE SEGMENTAL SHELL INSIDE DIAMETER FT 1.0000
SHELL TO BUNDLE CLEARANCE FT 0.1339
STREAMS:
--------------------------------------
| |
133 ----->| HOT (TUBE) |-----> 135
T= 3.8840D+02 | | T= 3.8830D+02
P= 2.1578D+02 | | P= 2.1551D+02
V= 1.0000D+00 | | V= 1.9389D-03
| |
35 <-----| COLD (SHELL) |<----- 34
T= 3.1000D+02 | | T= 3.1402D+02
P= 4.4724D+01 | | P= 4.9352D+01
V= 9.9611D-01 | | V= 0.0000D+00
--------------------------------------
DUTY AND AREA:
CALCULATED HEAT DUTY BTU/HR 2569821.1409 CALCULATED (REQUIRED) AREA SQFT 120.6854
ACTUAL EXCHANGER AREA SQFT 137.4450 PER CENT OVER-DESIGN 13.8869
PRESSURE DROP:
SHELLSIDE, BAFFLED FLOW AREA PSI 3.5285 SHELLSIDE, NOZZLE PSI 1.1017
SHELLSIDE, TOTAL PSI 4.6303 TUBESIDE, TUBES PSI 0.2798
TUBESIDE, NOZZLE PSI -0.0143 TUBESIDE, TOTAL PSI 0.2655
HOT (TUBE)
-------------------------------------------------------------
| |
133 | COND | 135
------> | |------>
388.4 | | 388.3
| |
35 | BOIL | 34
<------ | |<------
310.0 | | 314.0
| |
-------------------------------------------------------------
COLD (SHELL)