Calculo de Dotacion de Agua
Calculo de Dotacion de Agua
Calculo de Dotacion de Agua
Dotación para almacenamiento de 3 días: 7.87 m3/d x 3d = 23.61 m3
VTC = 17.10 m3
17.10 m3 = a x b x h si h = 1.8
17.10/1.8 = a x b si a=b
9.5 = a2
a = √9.5 = 3.08 m
VTE = 8.60 m3
8.60 m3 = a x b x h si h=1.40
8.60/1.4 = a x b si a=b
6.14 = a2
a = √6.14 = 2.48 m
Dotación para almacenamiento de agua para SS-HH de 3 días:
TE = 3.80m3
VTE = 3.80m3
3.80= a x b x h si h = 1.20m
3.80/1.20 = a x b si a=b
3.17 = a2
a = √3.17 = 1.78 m
H = PR – PS – HT
Dónde:
H = 22 – (2X1.42) - (1X1.42)
H = 17.74 lb/pl2
H = 8.87 lb/pl2
28 0.71
29 X
30 0.75
(0.75−0.71) ( 29−28)
𝑥= + 0.71
(30−28)
X = 0.73
85 1.5
88 X
90 1.56
(1.56−1.5) ( 88−85)
𝑥= + 1.50
(90−85)
X = 1.536
PISOS PIEZA TIPO CANTIDAD U.H TOTAL U.H
IMNODORO CON TANQUE 4 5 20
BEBEDERO SIMPLE 4 1 4
3° DUCHAS 4 4 16
LAVADERO DE COCINA 1 4 4
TOTAL U.H 44
90 1.56
92 X
95 1.62
(1.62−1.56) ( 92−90)
𝑥= + 1.56
(95−90)
X = 1.584
92 X
95 1.62
(1.62−1.56) ( 92−90)
𝑥= + 1.56
(95−90)
X = 1.584
48 1.09
49 X
50 1.13
(1.13−1.09) ( 49−48)
𝑥= + 1.09
(50−48)
X = 1.11
γ X Q X HD
PT =
75 X n
Donde:
n = eficiencia de la bomba
Q = caudal en m3/s
PT = potencia de la electrobomba