Fiber 2
Fiber 2
Fiber 2
Información general
Nombre de archivo: Fiber2.trc
Fecha de la prueba: 19/08/2021 Cliente: YOFC
Hora de la prueba: 16:35:43 Empresa: H&L
ID de cable: CA1T600039 ID de fibra: Fiber2
ID de trabajo: REGION SAN MARTIN
Comentarios:
Ubicaciones
Ubicación A Ubicación B
Ubicación A B
Operario H&L H&L
Modelo MAX-720C-SM1-EI
Número de serie 1391538
Fecha de calibración 14/10/2020 (UTC)
Results
Span length: 4.0032 km Average loss: 0.444 dB/km Injection level: 24.8 dB
Span loss: 1.779 dB Average splice loss: ---
Span ORL: 35.37 dB Maximum splice loss: ---
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.335 dB/km A-B average loss: 0.180 dB/km
a 0.0032 24.575 A-B LSA loss: 1.339 dB 4-point Event Loss: -0.682 dB
A 0.0032 24.575 A-B ORL: 35.65 dB Maximum reflectance: -71.9 dB
B 4.0044 23.856
b 4.0044 23.856
Macrobend
No macrobend detected.
Pass/Fail Thresholds
1310 nm (9 µm)
Fiber section attenuation (dB/km) 0.350
Test Parameters
A→B
Wavelength (nm) 1310 nm (9 µm)
Range (km) 6.0000
Pulse (ns) 100
Duration (s) 30
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.466700 1310 nm - 1550 nm 0.500
Backscatter (dB) -79.20
Helix factor (%) 1.35
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -78.0
End-of-fiber detection threshold (dB) 10.000
Ubicaciones
Ubicación A Ubicación B
Ubicación A B
Operario H&L H&L
Modelo MAX-720C-SM1-EI
Número de serie 1391538
Fecha de calibración 14/10/2020 (UTC)
Results
Span length: 4.0034 km Average loss: 0.275 dB/km Injection level: 23.4 dB
Span loss: 1.102 dB Average splice loss: ---
Span ORL: 37.13 dB Maximum splice loss: ---
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.191 dB/km A-B average loss: 0.007 dB/km
a 0.0032 23.319 A-B LSA loss: 0.765 dB 4-point Event Loss: -0.774 dB
A 0.0032 23.319 A-B ORL: 37.41 dB Maximum reflectance: -74.2 dB
B 4.0044 23.293
b 4.0044 23.293
Macrobend
No macrobend detected.
Pass/Fail Thresholds
1550 nm (9 µm)
Fiber section attenuation (dB/km) 0.200
Test Parameters
A→B
Wavelength (nm) 1550 nm (9 µm)
Range (km) 6.0000
Pulse (ns) 100
Duration (s) 30
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467100 1310 nm - 1550 nm 0.500
Backscatter (dB) -81.70
Helix factor (%) 1.35
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -78.0
End-of-fiber detection threshold (dB) 10.000