DISEÑO DE LOSA ALIGERADA

3 𝑉𝑆 25𝑥30
DATOS:
f´c = 210 Kg/cm2
Fy = 4200 Kg/cm2

𝑽𝑷 𝟐𝟓𝒙𝟑𝟓

𝑽𝑷 𝟐𝟓𝒙𝟓𝟓
SOBRE CARGA S/C = 75 Kg/cm2 2.48m
P. Acabados = 100 Kg/cm2
P. Tabiqueria = Kg/cm2

2 𝑉𝑆 25𝑥30
1𝑚
𝑚^2

𝑽𝑷 𝟐𝟓𝒙𝟑𝟓

𝑽𝑷 𝟐𝟓𝒙𝟓𝟓
2.48m

1 𝑉𝑆 25𝑥30
2.71m
A B
𝑃𝐿𝐴𝑁𝑇𝐴

1) CALCULO DE LA ALTURA DE LOSA MACIZA.

2.71m h=0.20 m
𝒉=𝑳/𝟐𝟓 ###
24

2) METRADO DE CARGAS.
a) Carga muerta o permanente. b) Carga Viva.
Peso propio de la Losa: 300.00 Kg/m2
Peso de Tarrajeo: 30.00 Kg/m2
Peso de teja andina: 12.00 Kg/m2
Peso de Cielorraso 50.00 Kg/m2
Peso de Ladrillo: 40.00 Kg/m2 c) Calculo de la Carga Ultima Ampificada.
TOTAL = WD = 432.00 Kg/m2 𝑾𝑼=𝟏.𝟒∗𝑾𝑫+𝟏.𝟕∗𝑾𝑳

d) Calculo de Carga Ultima por Vigueta.


〖𝑊𝑈〗 _𝑣𝑖𝑔𝑢𝑒𝑡𝑎
b = 0.40 m
WU = 0.732 Tn/m

30 cm 10 cm 30 cm 10 cm 30 cm

〖𝑾𝑼〗 _𝒗𝒊𝒈𝒖𝒆𝒕𝒂=𝑾𝑼∗𝒃 732.3 Kg/m2 * 0.40 m = 292.92 Kg/m WUvigueta = 0.293 Tn/m

3) CALCULO DE LOS MOMENTOS MAXIMOS USANDO METODO SIMPLIFICADO DE LOS COEFICIENTES.

WU = 0.293 Tn/m

𝑽𝑰𝑮𝑼𝑬𝑻𝑨 𝑴𝑨=𝟏/𝟐𝟒∗ 〖𝑾𝑼〗 _𝑽∗𝑳^𝟐


𝐴 𝑒𝑥𝑡. 𝐴 𝑒𝑥𝑡.
𝑴𝑩=𝟏/𝟐𝟒∗ 〖𝑾𝑼〗 _𝑽∗𝑳^𝟐
𝑉𝑃 𝑇. 𝐸𝑥𝑡. 𝑉𝑃
A B
𝑴𝑨𝑩=𝟏/𝟏𝟒∗ 〖𝑾𝑼〗 _𝑽∗𝑳^𝟐
2.71m
0.090 Tn.m
0.090 Tn.m

− −
𝐷.𝑀.𝐹.=
+

0.154Tn.m

4) CALCULO DEL REFUERZO NECESARIO.

A B
0.090 Tn.m 0.090 Tn.m
𝑀𝑈=
0.154Tn.m

0.017 0.017
𝑊=
0.029 h=0.20 m
ok ok
0.001 0.001
𝜌=
0.001
ok ∅= 0.90
0.1445 cm2 0.145 cm2
𝐴𝑠=
0.247 cm2 Ø (Pulg.) As (cm2)
Ø 1/4" 0.32
1.224 cm2 1.224 cm2 Ø 3/8" 0.71
〖𝐴𝑠〗 _𝑚𝑖𝑛= 0.306 cm2 Ø 1/2" 1.29
Ø 5/8" 2
1.224 cm2 1.224 cm2 Ø 3/4" 2.84
〖𝐴𝑠〗 _𝑝𝑟𝑒𝑣𝑖𝑠𝑡𝑜=
0.306 cm2 Ø 1" 5.1
Ø 1 1/8" 6.45
Ø 1 1/4" 8.19
Ø 1/2" cumple Ø 1/2" Ø 1 3/8" 10.07
∅=
Ø 1/2"
cumple

5) CALCULO DEL REFUERZO POR TEMPERATURA.

𝑇𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑎
b = 100cm

h=0.20 m

〖𝑨𝒔〗 _𝒎𝒊𝒏=𝟎.𝟎𝟎𝟏𝟖∗𝒃∗𝑻 0.0018 * 100 * 5 = 0.90cm2

*Considerando siempre Ø 1/4"

0.90cm2
#𝐵𝑎𝑟𝑟𝑎𝑠= 〖𝐴𝑠〗 _𝑚𝑖𝑛/ 〖𝐴𝑠〗 _𝑏 Ø 1/4"
= 3 Ø1/4 𝑺_𝒎𝒂𝒙=𝑺∗𝑻
0.32cm2

𝑺_∅=𝒃/(#𝑩𝒂𝒓𝒓𝒂𝒔) 100 cm → usaremos:


= 33 cm
3

*DISPOSICION DE LA ARMADURA.
𝑉𝑆

𝑙/5 𝑙/5

𝑙/6 𝑙/6

𝑽𝑷

𝑽𝑷
𝑉𝑆

Ø 1/2" Ø 1/2"
0.54m 0.68m
𝑽𝑷

𝑽𝑷
Ø 1/2"

𝑉𝑆
𝑃𝐿𝐴𝑁𝑇𝐴
𝑽𝑷 𝟐𝟓𝒙𝟓𝟓
𝑽𝑷 𝟐𝟓𝒙𝟓𝟓

B
𝑃𝐿𝐴𝑁𝑇𝐴

WL = 75.00 Kg/m2

Carga Ultima Ampificada.


+𝟏.𝟕∗𝑾𝑳 WU = 732 Kg/m2
WU = 0.732 Tn/m2
1
𝑼〗 _𝑽∗𝑳^𝟐 * 0.293 * 2.71^2 = 0.090 Tn.m
24
1
𝑼〗 _𝑽∗𝑳^𝟐 * 0.293 * 2.71^2 = 0.090 Tn.m
24
1
𝑾𝑼〗 _𝑽∗𝑳^𝟐 * 0.293 *2.71^2= 0.154Tn.m
14
7 Ø 1" 5.1

b = 40cm 𝒅=𝒉−𝟑

h=0.20 m
d = 17cm
17.000
bw=10 cm 10.000

0
0
0 0

T = 5cm

5 * 5 = 25 cm
#REF!

Ø 1/4" @ 25cm
0

0.05m

0.15m Ø 1/4"
@ 25cm

Acero𝑇𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑎

𝑅𝑒𝑓𝑢𝑒𝑟𝑧𝑜 𝑃𝑟𝑖𝑛𝑐𝑖𝑝𝑎𝑙 𝐷𝐸𝑇𝐴𝐿𝐿𝐸


𝐷𝐸
𝐿𝑂𝑆𝐴
𝐷𝐸𝑇𝐴𝐿𝐿𝐸
𝐷𝐸
𝐿𝑂𝑆𝐴