Tablas Xlpe TR
Tablas Xlpe TR
Tablas Xlpe TR
2
C
33.6
1/0
C
53.5
2/0
C
67.4
3/0
C
85
4/0
C
107
250
C
127
350
C
177
500
C
253
750
C
380
6.81
8.53
9.55
10.7
12.1
13.2
15.6
18.7
23.1
19
1.5
305.0
0.531
37
1.36
485.1
0.423
37
1.52
611.5
0.266
37
1.71
771.1
0.211
37
1.92
972.0
0.167
37
1.63
1149.0
0.141
61
2
1609.0
0.101
61
2.3
2298
0.0708
91
2.31
3447
0.0472
0.522
0.328
0.261
0.207
0.16
0.139
0.0991
0.069
0.0462
AISLAMIENTO:
XLPE-TR
ESPESOR:
NORMA ICEA S-93-639/NEMA WC 74-2006 (MILS) Tabla 4-4 Pg.17 o (Mtric) Tabla 4-4 Pag.18
8 KV
3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68
15 KV
5.21
5.21
5.21
5.21
5.21
5.21
5.21
5.21
5.21
25 KV
------
7.37
7.37
7.37
7.37
7.37
7.37
7.37
7.37
46 KV
------
------
------
------
12.6
12.6
12.6
12.6
12.6
8 KV
2,921
2,921
2,921
2,921
2,921
2,921
2,921
2,921
2,921
15 KV
4,445
4,445
4,445
4,445
4,445
4,445
4,445
4,445
4,445
NOMINAL (mm)
25 KV
6,604
6,604
6,604
6,604
6,604
6,604
6,604
6,604
6,604
46 KV
------
------
------
------
11,303
11,303
11,303
11,303
11,303
MXIMO (m.m)
MINIMO EN UN PUNTO, mm
8KV
2.79
2.79
2.79
2.79
2.79
2.79
2.79
2.79
2.79
15KV
4.19
4.19
4.19
4.19
4.19
4.19
4.19
4.19
4.19
25V
------
6.22
6.22
6.22
6.22
6.22
6.22
6.22
6.22
46KV
------
------
------
------
10.8
10.8
10.8
10.8
10.8
6,100
6,100
6,100
6,100
6,100
RESISTENCIA DE AISLAMIENTO
(Mohmio-Km)
6,100
6,100
6,100
6,100
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
1000
1000
1000
1000
1000
1000
1000
1000
1000
A 130C
1000
1000
1000
1000
1000
1000
1000
1000
1000
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
500
500
500
500
500
500
500
500
500
A 110C
500
500
500
500
500
500
500
500
500
BLINDAJE METALICO:
ESPESOR MNIMO, mm
0.06
ESPESOR DE LA CUBIERTA:
PROMEDIO MNIMO (mm)
(120% DEL MNIMO ESTABLECIDO EN LA NORMA)
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
15 KV
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
25 KV
-----
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
46 KV
-----
-----
-----
-----
2.03
2.03
2.03
2.79
2.79
8 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
2.54
15 KV
1.8
1.78
1.78
1.78
1.78
1.78
1.78
2.54
2.54
25 KV
-----
1.78
1.78
1.78
1.78
1.78
1.78
2.54
2.54
46 KV
-----
-----
-----
-----
1.78
1.78
1.78
2.54
Negro
Negro
Negro
Negro
Negro
Negro
Negro
Negro
2.54
Negro
CARGA MXIMA ADMISIBLE, PARA SERVICIO PERMANENTE CABLES AISLADOS CON XLPE
NORMA NEC (NATIONAL ELECTRICAL CODE HANDBOOK 2005) TABLAS Nos. 310.73 Y 310.77 (Pgs. 308 y 309)
CALIBRE AWG / Kcmil
CONDICIN DE LA INSTALACIN
1/0
2/0
3/0
4/0
250
(AMP)
350
500
750
155
200
230
260
295
325
390
465
565
150
195
225
260
295
330
395
480
585
act*-Pg. 9)
1000
C
507
26.9
91
2.66
4596
0.0354
0.0348
18
3.68
5.21
7.37
12.6
2,921
4,445
6,604
11,303
2.79
4.19
6.22
10.8
6,100
0.38
0.15
1000
1000
0.38
0.15
500
500
2.79
2.79
2.79
2.79
2.54
2.54
2.54
2.54
Negro
y 309)
1000
640
675
TABLA 2
CABLE APANTALLADO CON CINTA DE COBRE AL 133% DE AISLAMIENTO
CONDUCTOR DE COBRE NORMA ASTM B8 ICEA S-93-639/NEMA WC 74-2006 (Tabla 2-4-Columna Compact*-Pg. 9)
SECCION, mm: (Tabla 2-4 Pg. 9)
2
C
33.6
1/0
C
53.5
2/0
C
67.4
3/0
C
85
4/0
C
107
250
C
127
350
C
177
500
C
253
750
C
380
6.81
8.53
9.55
10.7
12.1
13.2
15.6
18.7
23.1
19
37
37
37
37
37
61
61
91
1.5
305.0
1.36
485.1
1.52
611.5
1.71
771.1
1.92
972.0
1.63
1149.0
2
1609.0
2.3
2298
2.31
3447
0.531
0.423
0.266
0.211
0.167
0.141
0.101
0.0708
0.0472
0.522
0.328
0.261
0.207
0.16
0.139
0.0991
0.069
0.0462
ESPESOR:
NORMA ICEA S-93-639/NEMA WC 74-2006 (MILS) Tabla 4-4 Pg.17 o (Mtric) Tabla 4-4 Pag.18
8 KV
4.32
4.32
4.32
4.32
4.32
4.32
4.32
4.32
4.32
15 KV
6.35
6.35
6.35
6.35
6.35
6.35
6.35
6.35
6.35
25 KV
------
8.89
8.89
8.89
8.89
8.89
8.89
8.89
8.89
46 KV
------
-------
-------
------
16
16
16
16
8 KV
3,556
3,556
3,556
3,556
3,556
3,556
3,556
3,556
3.56
15 KV
5,588
5,588
5,588
5,588
5,588
5,588
5,588
5,588
5.59
NOMINAL (mm)
25 KV
------
8,128
8,128
8,128
8,128
46 KV
------
-------
-------
-------
14,732 14,732
MXIMO (m.m)
MINIMO EN UN PUNTO, mm
8,128
8,128
16
8,128
8.13
14,732
14,732
14.73
8KV
3.43
3.43
3.43
3.43
3.43
3.43
3.43
3.43
3.43
15KV
5.33
5.33
5.33
5.33
5.33
5.33
5.33
5.33
5.33
25V
------
7.75
7.75
7.75
7.75
7.75
7.75
7.75
7.75
46KV
------
------
-------
-------
14
14
14
14
14
6,100
6,100
6,100
6,100
6,100
RESISTENCIA DE AISLAMIENTO
(Mohmio-Km)
6,100
6,100
6,100
6,100
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
1000
1000
1000
1000
1000
1000
1000
1000
1000
A 130C
1000
1000
1000
1000
1000
1000
1000
1000
1000
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
500
500
500
500
500
500
500
500
500
A 110C
500
500
500
500
500
500
500
500
500
BLINDAJE METALICO:
ESPESOR MNIMO, mm
0.06
ESPESOR DE LA CUBIERTA:
PROMEDIO MNIMO (mm)
(120% DEL MNIMO ESTABLECIDO EN LA NORMA)
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
15 KV
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
25 KV
-----
2.03
2.03
2.03
2.03
2.03
2.03
2.79
2.79
46 KV
-----
-----
-----
-----
2.03
2.03
2.03
2.79
2.79
8 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
2.54
15 KV
1.8
1.78
1.78
1.78
1.78
1.78
1.78
2.54
2.54
25 KV
-----
1.78
1.78
1.78
1.78
1.78
1.78
2.54
2.54
46 KV
-----
-----
-----
-----
1.78
1.78
1.78
2.54
Negro
Negro
Negro
Negro
Negro
Negro
Negro
Negro
2.54
Negro
CARGA MXIMA ADMISIBLE, PARA SERVICIO PERMANENTE CABLES AISLADOS CON XLPE
NORMA NEC (NATIONAL ELECTRICAL CODE HANDBOOK 2005) TABLAS Nos. 310.73 Y 310.77 (Pgs. 308 y 309)
CALIBRE AWG / Kcmil
CONDICIN DE LA INSTALACIN
1/0
2/0
3/0
4/0
250
(AMP)
350
500
750
155
200
230
260
295
325
390
465
565
150
195
225
260
295
330
395
480
585
act*-Pg. 9)
1000
C
507
26.9
91
2.66
4596
0.0354
0.0348
18
4.32
6.35
8.89
16
3.56
5.59
8.13
14.73
3.43
5.33
7.75
14
6,100
0.38
0.15
1000
1000
0.38
0.15
500
500
2.79
2.79
2.79
2.79
2.54
2.54
2.54
2.54
Negro
y 309)
1000
640
675
TABLA 3
CABLE NEUTRO CONCENTRICO HILOS DE COBRE 1/3 DE SECCIN 100% DE AISLAMIENTO
CONDUCTOR DE COBRE NORMA ASTM B8 ICEA S-93-639/NEMA WC 74-2006 (Tabla 2-4-Columna Compact*-Pg. 9)
2
C
33.6
6.81
1/0
C
53.5
8.53
2/0
C
67.4
9.55
3/0
C
85
10.7
4/0
C
107
12.1
250
C
127
13.2
350
C
177
15.6
500
C
253
18.7
750
C
380
23.1
19
37
37
37
37
37
61
61
91
1.5
305.0
0.531
0.522
1.36
485.1
0.423
0.328
1.52
611.5
0.266
0.261
1.71
771.1
0.211
0.207
1.92
972.0
0.167
0.16
1.63
1149.0
0.141
0.139
2
1609.0
0.101
0.0991
2.3
2298
0.0708
0.069
2.31
3447
0.0472
0.0462
ESPESOR:
3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68
15 KV
5.21
5.21
5.21
5.21
5.21
5.21
5.21
5.21
5.21
25 KV
------
7.37
7.37
7.37
7.37
7.37
7.37
7.37
7.37
46 KV
------
------
------
------
12.6
12.6
12.6
12.6
12.6
8 KV
2,921
2,921
2,921
2,921
2,921
2,921
2,921
2,921
2,921
15 KV
4,445
4,445
4,445
4,445
4,445
4,445
4,445
4,445
4,445
NOMINAL (mm)
25 KV
6,604
6,604
6,604
6,604
6,604
6,604
6,604
6,604
6,604
46 KV
------
------
------
------
11,303
11,303
11,303
11,303
11,303
MXIMO (m.m)
MINIMO EN UN PUNTO, mm
8KV
2.79
2.79
2.79
2.79
2.79
2.79
2.79
2.79
2.79
15KV
4.19
4.19
4.19
4.19
4.19
4.19
4.19
4.19
4.19
25V
------
6.22
6.22
6.22
6.22
6.22
6.22
6.22
6.22
46KV
------
------
------
------
10.8
10.8
10.8
10.8
10.8
6,100
6,100
6,100
6,100
6,100
RESISTENCIA DE AISLAMIENTO
(Mohmio-Km)
6,100
6,100
6,100
6,100
0.38
0.38
0.38
0.38
0.38
0.38
0.51
0.51
0.64
0.30
0.30
0.30
0.30
0.30
0.30
0.41
0.41
0.51
1000
1000
1000
1000
1000
1000
1000
1000
1000
A 130C
1000
1000
1000
1000
1000
1000
1000
1000
1000
0.76
0.76
0.76
0.76
0.76
0.76
1.02
1.02
0.76
1.52
1.52
1.52
1.52
1.52
1.52
1.91
1.91
1.52
500
500
500
500
500
500
500
500
500
A 110C
500
500
500
500
500
500
500
500
500
BLINDAJE METALICO:
NORMA:
ICEA S-94-649
17.83
22.47
28.35
35.73
42.22
CALIBRE AWG
SECCION, mm
16
16
16
16
14
14
CANTIDAD MIN.
14
18
22
MATERIAL DE LA CUBIERTA:
ESPESOR DE LACUBIERTA:
18
21
59.13
84.47
126.66
14
12
12
29
26
39
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
15 KV
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
25 KV
-----
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
46 KV
-----
-----
-----
-----
3.05
2.03
2.03
2.03
2.79
8 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.44
15 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.44
25 KV
-----
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.44
MNIMO)
46 KV
-----
-----
-----
-----
1.78
1.78
1.78
1.78
Negro
Negro
Negro
Negro
Negro
Negro
Negro
Negro
2.44
Negro
CARGA MXIMA ADMISIBLE, PARA SERVICIO PERMANENTE CABLES AISLADOS CON XLPE
NORMA NEC (NATIONAL ELECTRICAL CODE HANDBOOK 2005) TABLAS Nos. 310.73 Y 310.77 (Pgs. 308 y 309)
CALIBRE AWG / Kcmil
1/0
2/0
3/0
4/0
CONDICIN DE LA INSTALACIN
250
350
500
750
(AMP)
155
200
230
260
295
325
390
465
565
150
195
225
260
295
330
395
480
585
O
act*-Pg. 9)
1000
C
507
26.9
91
2.66
4596
0.0354
0.0348
3.68
5.21
7.37
12.6
2,921
4,445
6,604
11,303
2.79
4.19
6.22
10.8
6,100
0.64
0.51
1000
1000
1.02
1.91
500
500
OR
168.9
10
32
2.79
2.79
2.79
2.79
2.44
2.44
2.44
2.44
Negro
y 309)
1000
640
675
TABLA 4
CABLE NEUTRO CONCENTRICO HILOS DE COBRE 1/3 DE SECCIN 133% DE AISLAMIENTO
CONDUCTOR DE COBRE NORMA ASTM B8 ICEA S-93-639/NEMA WC 74-2006 (Tabla 2-4-Columna Compact*-Pg. 9)
CALIBRE AWG / Kcmil
CLASE
SECCION, mm: (Tabla 2-4 Pg. 9)
DIAMETRO NOMINAL , mm: (Tabla 2-4 Pg. 9)
NMER DE ALAMBRES COBRE: (Tabla H-3 Pg. 83)
DIAMETRO ALAMBRES: (Tabla H-3 Pg. 83)
PESO UNITARIO, Kg/Km: (Tabla H-1 Pg. 82)
RESISTE. DC MAX, 25C, ohm/Km (Tabla 2-3 Pg. 7)
RESIS. DC MAX, 20C, ohm/Km (INEN 2214 Tabla 4) ASTM B 496
1/0
2/0
3/0
4/0
250
350
500
750
C
33.6
6.81
19
1.5
305.0
0.531
0.522
C
53.5
8.53
37
1.36
485.1
0.423
0.328
C
67.4
9.55
37
1.52
611.5
0.266
0.261
C
85
10.7
37
1.71
771.1
0.211
0.207
C
107
12.1
37
1.92
972.0
0.167
0.16
C
127
13.2
37
1.63
1149.0
0.141
0.139
C
177
15.6
61
2
1609.0
0.101
0.0991
C
253
18.7
61
2.3
2298
0.0708
0.069
C
380
23.1
91
2.31
3447
0.0472
0.0462
ESPESOR:
4.32
4.32
4.32
4.32
4.32
4.32
4.32
4.32
4.32
15 KV
6.35
6.35
6.35
6.35
6.35
6.35
6.35
6.35
6.35
25 KV
------
8.89
8.89
8.89
8.89
8.89
8.89
8.89
8.89
46 KV
------
-------
-------
------
16
16
16
16
8 KV
3,556
3,556
3,556
3,556
3,556
3,556
3,556
3,556
3.56
15 KV
5,588
5,588
5,588
5,588
5,588
5,588
5,588
5,588
5.59
NOMINAL (mm)
25 KV
------
8,128
8,128
8,128
8,128
46 KV
------
-------
-------
-------
14,732 14,732
MXIMO (m.m)
MINIMO EN UN PUNTO, mm
8,128
8,128
16
8,128
8.13
14,732
14,732
14.73
8KV
3.43
3.43
3.43
3.43
3.43
3.43
3.43
3.43
3.43
15KV
5.33
5.33
5.33
5.33
5.33
5.33
5.33
5.33
5.33
25V
------
7.75
7.75
7.75
7.75
7.75
7.75
7.75
7.75
46KV
------
------
-------
-------
14
14
14
14
14
6,100
6,100
6,100
6,100
6,100
RESISTENCIA DE AISLAMIENTO
(Mohmio-Km)
6,100
6,100
6,100
6,100
0.38
0.38
0.38
0.38
0.38
0.38
0.51
0.51
0.64
0.30
0.30
0.30
0.30
0.30
0.30
0.41
0.41
0.51
1000
1000
1000
1000
1000
1000
1000
1000
1000
A 130C
1000
1000
1000
1000
1000
1000
1000
1000
1000
0.76
0.76
0.76
0.76
0.76
0.76
1.02
1.02
1.02
1.52
1.52
1.52
1.52
1.52
1.52
1.91
1.91
1.91
500
500
500
500
500
500
500
500
500
A 110C
500
500
500
500
500
500
500
500
500
BLINDAJE METALICO:
NORMA:
ICEA S-94-649
17.83
22.47
28.35
35.73
42.22
59.13
84.47
126.66
CALIBRE AWG
SECCION, mm
16
16
16
16
14
14
14
12
12
CANTIDAD MIN.
14
18
22
18
21
29
26
39
MATERIAL DE LA CUBIERTA:
ESPESOR DE LA CUBIERTA:
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
15 KV
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
25 KV
-----
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.79
46 KV
-----
-----
-----
-----
3.05
2.03
2.03
2.03
2.79
8 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.44
15 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.44
25 KV
-----
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.44
MNIMO)
46 KV
-----
-----
-----
-----
1.78
1.78
1.78
1.78
Negro
Negro
Negro
Negro
Negro
Negro
Negro
Negro
2.44
Negro
CARGA MXIMA ADMISIBLE, PARA SERVICIO PERMANENTE CABLES AISLADOS CON XLPE
NORMA NEC (NATIONAL ELECTRICAL CODE HANDBOOK 2005) TABLAS Nos. 310.73 Y 310.77 (Pgs. 308 y 309)
CALIBRE AWG / Kcmil
1/0
2/0
3/0
4/0
CONDICIN DE LA INSTALACIN
250
350
500
750
(AMP)
155
200
230
260
295
325
390
465
565
150
195
225
260
295
330
395
480
585
O
act*-Pg. 9)
1000
C
507
26.9
91
2.66
4596
0.0354
0.0348
4.32
6.35
8.89
16
3.56
5.59
8.13
14.73
3.43
5.33
7.75
14
6,100
0.64
0.51
1000
1000
1.02
1.91
500
500
OR
168.9
10
32
2.79
2.79
2.79
2.79
2.44
2.44
2.44
2.44
Negro
y 309)
1000
640
675
TABLA 5
CABLE APANTALLADO CON HILOS Y CINTA DE COBRE AL 100% DE AISLAMIENTO
CONDUCTOR DE COBRE NORMA ASTM B8 ICEA S-93-639/NEMA WC 74-2006 (Tabla 2-4-Columna Compact*-Pg. 9)
CALIBRE AWG / Kcmil
CLASE
SECCION, mm: (Tabla 2-4 Pg. 9)
DIAMETRO NOMINAL , mm: (Tabla 2-4 Pg. 9)
NMER DE ALAMBRES COBRE: (Tabla H-3 Pg. 83)
DIAMETRO ALAMBRES: (Tabla H-3 Pg. 83)
PESO UNITARIO, Kg/Km: (Tabla H-1 Pg. 82)
RESISTE. DC MAX, 25C, ohm/Km (Tabla 2-3 Pg. 7)
RESIS. DC MAX, 20C, ohm/Km (INEN 2214 Tabla 4) ASTM B 496
ESPESOR:
2
C
33.6
6.81
19
1.5
305.0
0.531
0.522
1/0
C
53.5
8.53
37
1.36
485.1
0.423
0.328
2/0
C
67.4
9.55
37
1.52
611.5
0.266
0.261
3/0
C
85
10.7
37
1.71
771.1
0.211
0.207
4/0
C
107
12.1
37
1.92
972.0
0.167
0.16
250
C
127
13.2
37
1.63
1149.0
0.141
0.139
350
C
177
15.6
61
2
1609.0
0.101
0.0991
500
C
253
18.7
61
2.3
2298
0.0708
0.069
750
C
380
23.1
91
2.31
3447
0.0472
0.0462
NORMA ICEA S-93-639/NEMA WC 74-2006 (MILS) Tabla 4-4 Pg.17 o (Mtric) Tabla 4-4 Pag.18
8 KV
3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68
3.68
15 KV
5.21
5.21
5.21
5.21
5.21
5.21
5.21
5.21
5.21
25 KV
------
7.37
7.37
7.37
7.37
7.37
7.37
7.37
7.37
46 KV
------
------
------
------
12.6
12.6
12.6
12.6
12.6
8 KV
2,921
2,921
2,921
2,921
2,921
2,921
2,921
2,921
2,921
15 KV
4,445
4,445
4,445
4,445
4,445
4,445
4,445
4,445
4,445
NOMINAL (mm)
25 KV
6,604
6,604
6,604
6,604
6,604
6,604
6,604
6,604
6,604
46 KV
------
------
------
------
11,303
11,303
11,303
11,303
11,303
MXIMO (m.m)
8KV
2.79
2.79
2.79
2.79
2.79
2.79
2.79
2.79
2.79
15KV
4.19
4.19
4.19
4.19
4.19
4.19
4.19
4.19
4.19
25V
------
6.22
6.22
6.22
6.22
6.22
6.22
6.22
6.22
46KV
------
------
------
------
10.8
10.8
10.8
10.8
10.8
6,100
6,100
6,100
6,100
6,100
MINIMO EN UN PUNTO, mm
RESISTENCIA DE AISLAMIENTO
(Mohmio-Km)
6,100
6,100
6,100
6,100
0.38
0.38
0.38
0.38
0.38
0.51
0.51
0.51
0.61
0.30
0.30
0.30
0.30
0.30
0.41
0.41
0.41
0.51
1000
1000
1000
1000
1000
1000
1000
1000
1000
A 130C
1000
1000
1000
1000
1000
1000
1000
1000
1000
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
500
500
500
500
500
500
500
500
500
A 110C
500
500
500
500
500
500
500
500
500
(REF:ENERSIS E-MT-012)
0.82
0.82
0.82
0.82
0.82
0.82
0.82
1.31
CALIBRE AWG
SECCION, mm
18
18
18
18
18
18
18
18
16
CANTIDAD MIN.
30
30
30
30
30
30
30
30
38
ESPESOR DE LA CUBIERTA:
PROMEDIO MNIMO (mm)
(120% DEL MNIMO ESTABLECIDO EN LA NORMA)
8 KV
2.14
2.14
2.14
2.14
2.14
2.14
2.14
2.14
3.05
15 KV
2.14
2.14
2.14
2.14
2.14
2.14
2.14
2.14
3.05
25 KV
-----
2.14
2.14
2.14
2.14
2.14
2.14
2.14
3.05
46 KV
-----
-----
-----
-----
2.14
2.14
2.14
2.14
3.05
8 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
15 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
25 KV
-----
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
46 KV
-----
-----
-----
-----
1.78
1.78
1.78
1.78
Negro
Negro
Negro
Negro
Negro
Negro
Negro
Negro
2.54
Negro
CARGA MXIMA ADMISIBLE, PARA SERVICIO PERMANENTE CABLES AISLADOS CON XLPE
NORMA NEC (NATIONAL ELECTRICAL CODE HANDBOOK 2005) TABLAS Nos. 310.73 Y 310.77 (Pgs. 308 y 309)
1/0
2/0
3/0
4/0
CONDICIN DE LA INSTALACIN
250
350
500
750
(AMP)
155
200
230
260
295
325
390
465
565
150
195
225
260
295
330
395
480
585
act*-Pg. 9)
1000
C
507
26.9
91
2.66
4596
0.0354
0.0348
18
y 309)
3.68
5.21
7.37
12.6
2,921
4,445
6,604
11,303
2.79
4.19
6.22
10.8
6,100
0.61
0.51
1000
1000
0.38
0.15
500
500
1.31
16
38
3.05
3.05
3.05
3.05
2.54
2.54
2.54
2.54
Negro
1000
640
675
TABLA 6
CABLE APANTALLADO CON HILOS Y CINTA DE COBRE AL 133% DE AISLAMIENTO
CONDUCTOR DE COBRE NORMA ASTM B8 ICEA S-93-639/NEMA WC 74-2006 (Tabla 2-4-Columna Compact*-Pg. 9)
2
C
33.6
6.81
19
1.5
305.0
1/0
C
53.5
8.53
37
1.36
485.1
2/0
C
67.4
9.55
37
1.52
611.5
3/0
C
85
10.7
37
1.71
771.1
4/0
C
107
12.1
37
1.92
972.0
250
C
127
13.2
37
1.63
1149.0
0.531
0.423
0.266
0.211
0.167
0.522
0.328
0.261
0.207
0.16
ESPESOR:
350
C
177
15.6
61
2
1609.0
500
C
253
18.7
61
2.3
2298
750
C
380
23.1
91
2.31
3447
0.141
0.101
0.0708
0.0472
0.139
0.0991
0.069
0.0462
NORMA ICEA S-93-639/NEMA WC 74-2006 (MILS) Tabla 4-4 Pg.17 o (Mtric) Tabla 4-4 Pag.18
8 KV
4.32
4.32
4.32
4.32
4.32
4.32
4.32
4.32
4.32
15 KV
6.35
6.35
6.35
6.35
6.35
6.35
6.35
6.35
6.35
25 KV
------
8.89
8.89
8.89
8.89
8.89
8.89
8.89
8.89
46 KV
------
-------
-------
------
16
16
16
16
8 KV
3,556
3,556
3,556
3,556
3,556
3,556
3,556
3,556
3.56
15 KV
5,588
5,588
5,588
5,588
5,588
5,588
5,588
5,588
5.59
NOMINAL (mm)
25 KV
------
8,128
8,128
8,128
8,128
46 KV
------
-------
-------
-------
14,732 14,732
MXIMO (m.m)
8,128
8,128
16
8,128
8.13
14,732
14,732
14.73
8KV
3.43
3.43
3.43
3.43
3.43
3.43
3.43
3.43
3.43
15KV
5.33
5.33
5.33
5.33
5.33
5.33
5.33
5.33
5.33
25V
------
7.75
7.75
7.75
7.75
7.75
7.75
7.75
7.75
46KV
------
------
-------
-------
14
14
14
14
14
6,100
6,100
6,100
6,100
6,100
MINIMO EN UN PUNTO, mm
RESISTENCIA DE AISLAMIENTO
(Mohmio-Km)
6,100
6,100
6,100
6,100
0.38
0.38
0.38
0.38
0.38
0.51
0.51
0.51
0.61
0.30
0.30
0.30
0.30
0.30
0.41
0.41
0.41
0.51
1000
1000
1000
1000
1000
1000
1000
1000
1000
A 130C
1000
1000
1000
1000
1000
1000
1000
1000
1000
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
500
500
500
500
500
500
500
500
500
A 110C
500
500
500
500
500
500
500
500
500
(REF:ENERSIS E-MT-012)
0.82
0.82
0.82
0.82
0.82
0.82
0.82
1.31
CALIBRE AWG
SECCION, mm
18
18
18
18
18
18
18
18
16
CANTIDAD MIN.
30
30
30
30
30
30
30
30
38
ESPESOR DE LA CUBIERTA:
PROMEDIO MNIMO (mm)
(120% DEL MNIMO ESTABLECIDO EN LA NORMA)
8 KV
2.14
2.14
2.14
2.14
2.14
2.14
2.14
2.14
3.05
15 KV
2.14
2.14
2.14
2.14
2.14
2.14
2.14
2.14
3.05
25 KV
-----
2.14
2.14
2.14
2.14
2.14
2.14
2.14
3.05
46 KV
-----
-----
-----
-----
2.14
2.14
2.14
2.14
3.05
8 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
15 KV
1.78
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
25 KV
-----
1.78
1.78
1.78
1.78
1.78
1.78
1.78
2.54
46 KV
-----
-----
-----
-----
1.78
1.78
1.78
1.78
Negro
Negro
Negro
Negro
Negro
Negro
Negro
Negro
2.54
Negro
CARGA MXIMA ADMISIBLE, PARA SERVICIO PERMANENTE CABLES AISLADOS CON XLPE
NORMA NEC (NATIONAL ELECTRICAL CODE HANDBOOK 2005) TABLAS Nos. 310.73 Y 310.77 (Pgs. 308 y 309)
1/0
2/0
3/0
4/0
CONDICIN DE LA INSTALACIN
250
350
500
750
(AMP)
155
200
230
260
295
325
390
465
565
150
195
225
260
295
330
395
480
585
act*-Pg. 9)
1000
C
507
26.9
91
2.66
4596
0.0354
0.0348
18
y 309)
4.32
6.35
8.89
16
3.56
5.59
8.13
14.73
3.43
5.33
7.75
14
6,100
0.61
0.51
1000
1000
0.38
0.15
500
500
1.31
16
38
3.05
3.05
3.05
3.05
2.54
2.54
2.54
2.54
Negro
1000
640
675