Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Detalles Estructurales para Viviendas

Descargar como pdf o txt
Descargar como pdf o txt
Está en la página 1de 1

0.

70

0.70 0.275 0.15 0.275

0.075 0.55 0.075


0.15 0.15 0.15

0.15
REFUERZO VARRILLA NO.4

INDICA COLUMNA EST. No.2 ESL. No.2 EST. No.2

0.21

0.21
EST.No.2

0.19
ALTURA COLUMNA
VARIABLE SEGÚN
PROYECCIÓN @ 0.15 @ 0.15 @ 0.15

0.15
@ 0.15
COLUMNA TIPO A

EST. No. 3 @ 0.15


2 VARILLA No. 3

0.70
A CIMIENTO CORRIDO
4 VARILLAS No.3
BLOCK TIPO U PREFABRICADO
4 VARILLAS No.3 4 VARILLAS No.4

4 NO.3 + EST. NO.2 @ 0.15 RECUBRIMIENTO 2.5 CMS. 4 NO.3 + EST. NO.2 @ 0.15 4 NO.4 + EST. No.2 @ 0.15

INDICA REFUERZO RECUBRIMIENTO 2.5 CMS. RECUBRIMIENTO 2.5 CMS. RECUBRIMIENTO 2.5 CMS.
0.075
No. 4 COLUMNA

0.20
REFUERZO
No. 4 @ 0.10
solera corona solera intermedia solera intermedia columna tipo A
EN AMBOS SENTIDOS
esc: 1:10 esc: 1:10 esc: 1:10 esc: 1:10

0.075
- REFUERZO No. 4 @ 0.10 Mt EN AMBOS SENTIDOS
- RECUBRIMIENTO 0.075 Mt

planta zapata tipo 1 sección a-a' zapata tipo 1


concentríca concentríca
esc: 1:12.5 esc: 1:12.5
0.70

0.70 0.20 0.50


0.075 0.55 0.075

REFUERZO VARRILLA NO.4

ALTURA COLUMNA
COLUMNA

VARIABLE SEGÚN
INDICA

PROYECCIÓN
0.30
COLUMNA
0.15
EST. No. 3 @ 0.15 0.15
0.70

A CIMIENTO CORRIDO
0.15
EST. No.2 EST. No.2

0.30
0.27
0.21
INDICA REFUERZO EST. No.2 @ 0.15
0.075 @ 0.15
No. 4 COLUMNA @ 0.15 EST.No.2

0.20

0.15
@ 0.15
REFUERZO
No. 4 @ 0.10
EN AMBOS SENTIDOS 4 VARILLAS No.4
6 VARILLAS No.4 8 VARILLAS No.4

0.075
- REFUERZO No. 4 @ 0.10 Mt EN AMBOS SENTIDOS 4 VARILLAS No.3
4 NO.4 + EST. NO.2 @ 0.15
- RECUBRIMIENTO 0.075 Mt
6 NO.4 + EST. NO.2 @ 0.15 8 NO.4 + EST. NO.2 @ 0.15
RECUBRIMIENTO 2.5 CMS. 4 NO.4 + EST. No.2 @ 0.15
RECUBRIMIENTO 2.5 CMS. RECUBRIMIENTO 2.5 CMS.
RECUBRIMIENTO 2.5 CMS.

planta zapata tipo 1 sección a-a' zapata tipo 1 columna tipo A-1 columna tipo A-2 columna tipo A-3 columna tipo b
colindante colindante esc: 1:10 esc: 1:10 esc: 1:10 esc: 1:10
esc: 1:12.5 esc: 1:12.5

1.00
0.075 0.85 0.075
0.075

1.00

INDICA
0.35 0.30 0.35
PROYECCIÓN

COLUMNA TIPO A

REFUERZO VARRILLA NO.4


0.15
ALTURA COLUMNA

COLUMNA
VARIABLE SEGÚN

A
0.85
1.00

0.15

0.10
EST. No. 3 @ 0.15

0.27
INDICA REFUERZO EST. No.2 EST. No.2

0.21
No. 4 COLUMNA
@ 0.15 @ 0.15 ESL. No.2

0.15
CIMIENTO CORRIDO
@ 0.15

0.075
2 VARILLAS No.3
0.20

4 VARILLAS No.3 6 VARILLAS No.3


REFUERZO
No. 4 @ 0.10
4 NO.3 + EST. NO.2 @ 0.15 6 NO.3 + EST. NO.2 @ 0.15 2 NO.3 + ESL. No.2 @ 0.15
EN AMBOS SENTIDOS
- REFUERZO No. 4 @ 0.10 Mt EN AMBOS SENTIDOS RECUBRIMIENTO 2.5 CMS. RECUBRIMIENTO 2.5 CMS. RECUBRIMIENTO 2.5 CMS.
0.075

0.075

- RECUBRIMIENTO 0.075 Mt

columna tipo b-1 columna tipo b-2 columna tipo c


esc: 1:10 esc: 1:10 esc: 1:10
planta zapata tipo 2 sección a-a' zapata tipo 2
concentríca concentríca esc: 1:12.5
esc: 1:12.5

1.00
0.075 0.85 0.075
0.075

1.00

0.30 0.70

0.20

REFUERZO VARRILLA NO.4


ESL. NO.2 @ 0.19
ALTURA COLUMNA

COLUMNA
VARIABLE SEGÚN
0.85
1.00

0.08
EST. No.2
A
INDICA
0.30

@ 0.15
PROYECCIÓN EST. No. 3 @ 0.15
COLUMNA

0.19

0.19
TIPO A3
6 NO.4 + EST. NO.2 @ 0.15
CIMIENTO CORRIDO
RECUBRIMIENTO 2.5 CMS.

INDICA REFUERZO
0.075
No. 4 COLUMNA 6 VARILLAS No.4
1 VARILLA 1 VARILLA
0.20

No.3 o No. 4 No.3 o No. 4


REFUERZO
No. 4 @ 0.10

- REFUERZO No. 4 @ 0.10 Mt EN AMBOS SENTIDOS


EN AMBOS SENTIDOS SECCIÓN TRANSVERSAL
0.075

0.075

- RECUBRIMIENTO 0.075 Mt VIGA DE CIMENTACIÓN detalle anclaje pines detalle pin aislado
esc: 1:10 esc: 1:10 esc: 1:10

planta zapata tipo 2 sección a-a' zapata tipo 2


conlindante colindante
esc: 1:12.5 esc: 1:12.5