CURI, Yoni - AI-441 REPORTE N°7
CURI, Yoni - AI-441 REPORTE N°7
CURI, Yoni - AI-441 REPORTE N°7
AYACUCHO – PERU
2024
I. OBJETIVOS
II. DATOS
Tabla N° 01
Tabla N° 03
L (m) 5.20 m
di 0.0132
Lado del tubo interno
do 0.016
Di 0.023
Lado del tubo externo
Do 0.025
Tabla N° 04
Tabla N° 05
Tabla N° 06
Paralelo Cp ρ k µ pr
Tp °C J/Kg°C Kg/m^3 W/m. K Kg/m. s
28.35 4180.40 997.35 0.609 0.000750 6.3090
Fluido
28.85 4180.76 997.77 0.613 0.000780
frio
28.2 4180.20 997.25 0.607 0,000744
51,75 4182.60 987.60 0.6453 0.000545
Fluido 49.35 4181.40 987.32 0.635 0.000546
caliente 45.05 4180.06 990.6 0.638 0.000597
Tabla N° 07
Contracorriente Cp ρ k µ
Tp °C J/Kg°C Kg/m^3 W/m.°K Kg/m. s
28.65 4178.50 996.63 0.6166 0.000796
Fluido
29.70 4178.83 996.71 0.6172 0.000797
frio
28.35 4178.31 996.41 0.6154 0.000796
52.10 4181.74 988.11 0.6446 0.000547
Fluido 50.80 4181.17 988.15 0.6442 0.000508
caliente 47.55 4180.43 995.45 0.6441 0.000555
𝑚 = 𝑄 ∗ 𝜌 = 0.00010𝑚3/𝑠 ∗ 997.35𝑘𝑔/𝑚3
𝑚 = 0.099735kg/s
Hallando q experimental
𝒒 = 6547. 4013𝑾
Hallamos velocidad
𝑄 0.00010𝑚3/𝑠
𝑉= = = 0.0003826𝑚/𝑠
Ao 0.2614𝑚2
Hallamos NRe
997.35𝑘𝑔
𝑚3𝑥0.0003826𝑚
𝑠𝑥0.016𝑚
NRe= kg =8.1405
0.000750 m .s
Hallamos Uo experimental
𝐴𝑇2 − 𝐴𝑇1
𝐴𝑇𝐿 = 𝐴𝑇2
𝐿𝑛(𝐴𝑇 )
1
42.5°𝐶 − 6.4°𝐶
𝐴𝑇𝐿 = = 23.26°𝐶
𝐿𝑛(42.5°𝐶
6.4°𝐶 )
𝑞
𝑈𝑜 =
𝐴𝑜 ∗ 𝐴𝑇𝐿
6547. 4013W
𝑈𝑜 =
0.2614𝑚2 ∗ 23.26°𝐶
𝑈𝑜 = 1076.8462𝑊/𝑚2. 𝐾
Hallamos coeficiente individual de transferencia de calor experimental (hi), del lado del
tubo.
𝜌. 𝑉. 𝑑𝑖 𝐶𝑝. 𝑢 1/3
0.023𝑥𝑘𝑥( )0.8𝑥( )
ℎ𝑖 = 𝑢 𝑘
𝑑𝑖
0.0132
hi=21.6715
𝑁𝑢 = 0.023(𝑅𝑒)0.8(𝑃𝑟)1/3
ℎ𝑜 = 1270.0885𝑊/𝑚2. 𝐾
𝑑𝑖
ℎ𝑖𝑜 = ( )
𝑑𝑜
0.0132
ℎ𝑖𝑜 = 21.6715𝑥( )
0.016
ℎ𝑖𝑜 =1 7 . 8 7 9 0 𝑊/𝑚2. 𝐾
𝑘𝑎𝑐𝑒𝑟𝑜 = 50.2𝑊/𝑚. 𝐾
• Hallamos el coeficiente global teórico de transferencia de calor (Uo)
𝑼𝒐 = 𝟏7.6213𝑾/𝒎𝟐. 𝑲
𝑚 = 0.00099kg/s
Hallando q experimental
q=0.00099kg/sx4182.60J/Kg.°Cx (62.7-40.8)°C=90.6830
Hallamos velocidad
0.00001𝑚3/𝑠
v= = 4.638x10-5m/s
0.2156𝑚2
Hallamos NRe
= 987.60kg/m3x0.0003826m/sx0..0132m
=9.1517
0.000545kg/m.s
Hallamos Uo experimental
𝐴𝑇2 − 𝐴𝑇1
𝐴𝑇𝐿 = 𝐴𝑇2
𝐿𝑛(𝐴𝑇 )
1
20.3°𝐶 – 36.5°𝐶
𝐴𝑇𝐿 = = 27.61°𝐶
𝐿𝑛(20.3°𝐶
36.5°𝐶 )
𝑞
𝑈𝑜 =
𝐴𝑖 ∗ 𝐴𝑇𝐿
Tabla 10
Hallamos coeficiente individual de transferencia de calor experimental (ho), del lado del anulo.
Tabla 11
ho hio
7.21511 6.266006
fluido 7.32543 6.361816
frio 7.26424 6.308671
10.8227 9.399061
fluido 17.0474 14.80493
caliente 38.404 33.3522
Uo
2.6635
fluido 2.69574
frio 2.67788
3.62255
fluido 4.91493
caliente 7.50308
Tabla 13
log
un pr re log(nu/pr) re
fluido 1.87977 5.6576 120.23 -0.479 2.08
frio 1.9052 5.5856 122.91 -0.467 2.09
1.89355 5.6792 121.14 -0.477 2.083
fluido 2.25833 3.445 185.56 -0.183 2.268
caliente 3.7237 3.5968 340.6 0.0151 2.532
11.9567 3.8344 1425.9 0.4939 3.154
GRAFICA T VS Z
T°C
Z(m)
𝑚 = 0.099663kg/s
Hallando q experimental
𝒒 =8370. 4811𝑾
Hallamos velocidad
𝑄 0.00010𝑚3/𝑠
𝑉= = = 0.0003826𝑚/𝑠
Ao 0.2614𝑚2
Hallamos NRe
996.63𝑘𝑔 m
𝜌 𝑥 𝑣 𝑥 𝑑𝑜 𝑥0.0007040 s 𝑥 0.016𝑚
𝑁𝑟𝑒 = = 𝑚3 =
u 0.000796 kg/m. s
Nre=14.1031
Hallamos Uo experimental
𝐴𝑇2 − 𝐴𝑇1
𝐴𝑇𝐿 = 𝐴𝑇2
𝐿𝑛(𝐴𝑇 )
1
1.3°𝐶 – 45.6°𝐶
𝐴𝑇𝐿 = = 12.45°𝐶
𝐿𝑛(1.3°𝐶
45.6°𝐶
𝑈𝑜 = 𝑞
𝐴𝑜 ∗ 𝐴𝑇𝐿
𝑈𝑜 8370. 4811W
=
0.2614𝑚2 ∗ 12.45°𝐶
𝑼𝒐 =2572.0227 𝑾/𝒎𝟐. 𝑲
Hallamos coeficiente individual de transferencia de calor experimental (hi), para tubo
interno (caliente)
Kg 𝐽
0.099663 ∗ 4181.74 ∗ (40 – 64.2)°𝐶
𝑠 𝑘𝑔°𝐶
ℎ𝑖 = 2
0.2156𝑚 ∗ 34.2°𝐶
ℎ𝑖 = 1367.8279𝑊/𝑚2. 𝐾
ℎ𝑜 =58.7206𝑊/𝑚2. 𝐾
ℎ𝑖𝑜 = 1 1 2 8 4 . 5 8 0 𝑊/𝑚2. 𝐾
𝑘𝑎𝑐𝑒𝑟𝑜 = 50.2𝑊/𝑚. 𝐾
1
=
U° 1 0.0132𝑚 0.016𝑚 1
+ 𝑥 )+
11284.580𝑊/𝑚2. 𝐾 2 ∗ 50.2𝑊/𝑚. 𝐾 0.0132𝑚 58.7206𝑊 /𝑚2. 𝐾
𝑈𝑜 = 58.3304 𝑊/𝑚2. 𝐾
𝑁𝑢 = 0.023(𝑅𝑒)0.8(𝑃𝑟)1/3
𝑁𝑢 = 0.023(14.1031)0.8(6,4425)1/3
Nu=0.3555
Tabla 10
16.2157975
%eficiencia= 25.5227502
28.7836103