Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Access Control Terminal: User Manual

Télécharger au format pdf ou txt
Télécharger au format pdf ou txt
Vous êtes sur la page 1sur 24

Access Control Terminal

User Manual
UD.6L0206D1135A01
Access Control Terminal·User Manual
User Manual
© 2015 Hangzhou Hikvision Digital Technology Co., Ltd.

This manual is applied for access control terminal.

Product
Model Product Name
Serials
Access Control Terminal
DS-K1T801E
(EM Card)
DS-K1T801
Access Control Terminal
DS-K1T801M
(Mifare Card)

It includes instructions on how to use the Product. The software


embodied in the Product is governed by the user license
agreement covering that Product.

About this Manual


This Manual is subject to domestic and international copyright
protection. Hangzhou Hikvision Digital Technology Co., Ltd.
(“Hikvision”) reserves all rights to this manual. This manual cannot
be reproduced, changed, translated, or distributed, partially or
wholly, by any means, without the prior written permission of
Hikvision.

Trademarks
and other Hikvision marks are the property of
Hikvision and are registered trademarks or the subject of
applications for the same by Hikvision and/or its affiliates. Other
trademarks mentioned in this manual are the properties of their
respective owners. No right of license is given to use such
trademarks without express permission.

i
Access Control Terminal·User Manual
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW,
HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
REGARDING THIS MANUAL. HIKVISION DOES NOT WARRANT,
GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE
USE OF THE MANUAL, OR THE CORRECTNESS, ACCURACY, OR
RELIABILITY OF INFORMATION CONTAINED HEREIN. YOUR USE OF
THIS MANUAL AND ANY RELIANCE ON THIS MANUAL SHALL BE
WHOLLY AT YOUR OWN RISK AND RESPONSIBILITY.

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN


NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES,
OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL,
CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,
INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS
PROFITS, BUSINESS INTERRUPTION, SECURITY BREACHES, OR LOSS
OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE
OF OR RELIANCE ON THIS MANUAL, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR


LIMITATION OF LIABILITY OR CERTAIN DAMAGES, SO SOME OR ALL
OF THE ABOVE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO
YOU.

Support
Should you have any questions, please do not hesitate to contact
your local dealer.

0100001051122

ii
Access Control Terminal·User Manual
Regulatory Information
FCC Information
FCC compliance: This equipment has been tested and found to
comply with the limits for a digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
EU Conformity Statement
This product and - if applicable - the supplied
accessories too are marked with "CE" and comply
therefore with the applicable harmonized European
standards listed under the Low Voltage Directive 2006/95/EC, the
EMC Directive 2004/108/EC, the RoHS Directive 2011/65/EU.

2012/19/EU (WEEE directive): Products marked with


this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more information
see: www.recyclethis.info.
iii
Access Control Terminal·User Manual

2006/66/EC (battery directive): This product contains


a battery that cannot be disposed of as unsorted
municipal waste in the European Union. See the
product documentation for specific battery
information. The battery is marked with this symbol,
which may include lettering to indicate cadmium (Cd), lead (Pb),
or mercury (Hg). For proper recycling, return the battery to your
supplier or to a designated collection point. For more information
see: www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (A)/NMB-3(A) standards
requirements.
Safety Instruction
These instructions are intended to ensure that user can use the
product correctly to avoid danger or property loss.
The precaution measure is divided into Warnings and Cautions:
Warnings: Neglecting any of the warnings may cause serious
injury or death.
Cautions: Neglecting any of the cautions may cause injury or
equipment damage.

Warnings Follow Cautions Follow these


these safeguards to precautions to prevent
prevent serious injury potential injury or
or death. material damage.

iv
Access Control Terminal·User Manual

Warnings
 All the electronic operation should be strictly compliance with
the electrical safety regulations, fire prevention regulations and
other related regulations in your local region.
 Please use the power adapter, which is provided by normal
company. The power consumption cannot be less than the
required value.
 Do not connect several devices to one power adapter as
adapter overload may cause over-heat or fire hazard.
 Please make sure that the power has been disconnected before
you wire, install or dismantle the device.
 When the product is installed on wall or ceiling, the device shall
be firmly fixed.
 If smoke, odors or noise rise from the device, turn off the
power at once and unplug the power cable, and then please
contact the service center.
 If the product does not work properly, please contact your
dealer or the nearest service center. Never attempt to
disassemble the device yourself. (We shall not assume any
responsibility for problems caused by unauthorized repair or
maintenance.)

Cautions
 Do not drop the device or subject it to physical shock, and do
not expose it to high electromagnetism radiation. Avoid the
equipment installation on vibrations surface or places subject to
shock (ignorance can cause equipment damage).
 Do not place the device in extremely hot (refer to the
specification of the device for the detailed operating
temperature), cold, dusty or damp locations, and do not expose
it to high electromagnetic radiation.
 The device cover for indoor use shall be kept from rain and
moisture.

v
Access Control Terminal·User Manual
 Exposing the equipment to direct sun light, low ventilation or
heat source such as heater or radiator is forbidden (ignorance
can cause fire danger).
 Do not aim the device at the sun or extra bright places. A
blooming or smear may occur otherwise (which is not a
malfunction however), and affecting the endurance of sensor at
the same time.
 Please use the provided glove when open up the device cover,
avoid direct contact with the device cover, because the acidic
sweat of the fingers may erode the surface coating of the device
cover.
 Please use a soft and dry cloth when clean inside and outside
surfaces of the device cover, do not use alkaline detergents.
 Please keep all wrappers after unpack them for future use. In
case of any failure occurred, you need to return the device to
the factory with the original wrapper. Transportation without
the original wrapper may result in damage on the device and
lead to additional costs.
 Improper use or replacement of the battery may result in
hazard of explosion. Replace with the same or equivalent type
only. Dispose of used batteries according to the instructions
provided by the battery manufacturer.

vi
Access Control Terminal·User Manual
Table of Contents
1 Overview ...................................................................................................... 1
2 Appearance .................................................................................................. 2
2.1 Appearance of the Termianl ................................................... 2
2.2 Description of Keypad Items .................................................. 3
3 Terminal Connection .................................................................................... 4
3.1 Terminal Description .............................................................. 4
3.2 External Device Wiring ........................................................... 5
4 Installation ................................................................................................... 7
4.1 Mounting with Gang Box ....................................................... 7
4.2 Mounting without Gang Box .................................................. 8
5 Keypad Operation ...................................................................................... 10
5.1 Working Mode ..................................................................... 10
5.2 Programming Mode ............................................................. 11

vii
Access Control Terminal·User Manual

1 Overview

Figure 1-1 DS-K1T801 Series Standalone Access Control


Terminal
Main Features
 Equipped with 32-bit high-speed processor
 The communication data is specially encrypted to relieve the
concern of privacy leak
 Supports EM card and Mifare card reading
 Supports authentication methods of card, card and password
 Doorbell ring design
 Supports 3 thousand card No. storage
 Unlocking overtime alarm
 Data can be permanently saved after power-off
 Watchdog program to ensure the basic function of the
terminal

1
Access Control Terminal·User Manual
2 Appearance
2.1 Appearance of the Termianl
Please refer to the following content for detailed information of
the terminal.

Figure 2-1 Appearance of Access Control Terminal


Table 2-1 Description of Access Control Terminal
No. Name Description
1 Slow Flicking Card reader is
Green working properly.
The operation of
Solid Green
pressing keys or
Power for a period
Indicator swiping card is valid.
The operation of
Solid Red for pressing keys or
a period swiping card is
invalid.
2
Access Control Terminal·User Manual
No. Name Description
2 Numeric key 0 to 9, Clearing key *,
Keypad and Confirming key #
3 Door Bell Door Bell Ring

2.2 Description of Keypad Items


Table 2-2 Description of Keys
No. Description
0 to 9 Numeric Keys: Enter number in the
textbox.
* Exiting Key: Click the key to exit the
menu.
# Confirming Key: Click the key to
confirm operations.

3
Access Control Terminal·User Manual
3 Terminal Connection
3.1 Terminal Description
The following table shows the terminals description

Table 3-1 Terminal Description

Description Color
12V DC Red
Power Input
GND Black
Bell+ Orange
Bell
Bell- Yellow
BUTTON_IN Purple
DOOR_COM Green
DOOR_NO/NC Blue
Door Lock
SENSOR_IN White
GND Black
12V_LOCK Brown

4
Access Control Terminal·User Manual
3.2 External Device Wiring
Power Supply Wiring Doorbell Wiring

Figure 3-1 Power Supply Figure 3-2 Doorbell Wiring


Connection Diagram Diagram
Door Button Wiring Door Lock Wiring

Figure 3-3 Door Button Wiring Figure 3-4 Door Lock Wiring
Diagram Diagram

5
Access Control Terminal·User Manual
Door Magnetic Wiring

Figure 3-5 Door Magnetic Wiring Diagram

6
Access Control Terminal·User Manual
4 Installation
Before you start
 Please make sure that the device in the package is in good
condition and all the assembly parts are included.
 Make sure that all the related equipment is power-off during
the installation.
 Check the specification of the products for the installation
environment.
 Check whether the power supply is matched with your AC
outlet to avoid damage.
 If the product does not function properly, please contact your
dealer or the nearest service center. Do not disassemble the
camera for repair or maintenance by yourself.
 Please make sure the wall is strong enough to withstand three
times the weight of the camera and the mounting.

4.1 Mounting with Gang Box


Steps:
1. Route the cables through the cable hole of the mounting base.
2. Align the screw holes on mounting base with the screw holes on
gang box.
3. Fix the mounting base on the gang box with inserting two
KA4*22-SUS screws (supplied) into the two screw holes.

7
Access Control Terminal·User Manual

Figure 4-1 Install the Mounting Figure 4-2 Attach the Front
Base Cover
4. Connect the corresponded cables.
5. Align the buckle of the front cover with the slot of the mounting
base, and hang the front cover onto the mounting base. Make
sure the buckle is embedded into the slot.
6. Secure the front cover with inserting and tightening two screws
on the bottom of device.

Figure 4-3 Secure the Front Cover

4.2 Mounting without Gang Box


Steps:
1. Drill 4 screw holes in the wall according to the holes of the
mounting base, and then insert expansion screws sockets (not
supplied) into the holes.
2. Route the cables through the cable hole of the mounting base.

8
Access Control Terminal·User Manual
3. Align the screw holes on the base with the screw sockets on the
wall.
4. Attach the mounting base on the wall with Inserting 4
KA4*22-SUS screws (supplied) into the 4 screw sockets.

Figure 4-4 Install the Figure 4-5 Attach the Front


Mounting Base Cover
5. Connect the corresponded cables.
6. Align the buckle of the front cover with the slot of the mounting
base, and hang the front cover onto the mounting base. Make
sure the buckle is embedded into the slot.
7. Secure the front cover with inserting and tightening two screws
on the bottom of the device.

Figure 4-6 Secure the Front Cover

9
Access Control Terminal·User Manual
5 Keypad Operation
Access Control Terminal Working Mode
The access controller involves two modes: working mode and
programming mode.

5.1 Working Mode


After the access controller is powered on, its LED status indicator
turns green and blinks for 1 time firstly. Then it turns red and
blinks for 3 times, and the buzzer buzzes a beep sound indicating
the initialization process is completed.
 The controller supports swiping card, E series support EM
card, and M series support Mifare card.
 The controller also supports entering card No. by keypad. For
example, you can enter the card number by ending with #.
Enter the * key to clear the valid data input before, for example,
the valid data of “123456*7890123#” is “7890123”.
Enter [the programming password] + [*] + [0] + [#] to enter the
programming mode. The default programming password is 12345.
When using the access control terminal, it will send out different
sound prompt and the LED indicator on it has different statues.
For the detailed information, refer to the table below.
Sound LED Indicator Description
Prompt Status
Green and The access controller is
blinking slowly working normally.
Pressing keys prompt;
One beep
Swiping card prompt.
Two rapid Solid green The operation of pressing keys
beeps or swiping card is valid.
Three slow Solid red The operation of pressing keys
beeps or swiping card is invalid.
Two rapid The operation of entering the
10
Access Control Terminal·User Manual
Sound LED Indicator
Prompt Status Description
beeps programming mode is
successful.
Three slow The operation of entering the
beeps programming mode is failed.
Delayed door alarm (the door
Beep for 10
seconds is opened over the time
limitation)

5.2 Programming Mode


After entering the programming mode, LED status indicator turns
green and blinks rapidly.
After entering “*#”, the buzzer buzzes two rapid beeps for
switching the programming mode to the normal mode.
Change Password:
Command:
[00]+ [5-bit programming password]+[5-bit programming
password]+[#]

Sound Description
Prompt
3 slow beeps The operation of changing password is
failed.
2 rapid beeps The operation of changing password is
successful.

Add User:
Two ways are allowed to add the user: single adding and
continuous adding.
Steps:
1. Enter the user ID.

11
Access Control Terminal·User Manual
2. Swiping the card.
3. Enter the 6-bit card password.

The step 3 can be omitted, and the default card password is


000000.
 Single adding:
[01] +[4-bit code]+ [swipe card 1]+ [6-bit open door
password]+[#]
 Continuous adding:
[01] +[4-bit code]
+ [swipe card 1]+ [6-bit open door password]
+ [swipe card 2]+ [6-bit open door password]

+[#]
The open door password settings is optional.
Enter the 4-bit user ID, e.g. “0001” (note: the 4-bit user ID ranges
from 1 to 3000).
Sound Description
Prompt
3 slow beeps Enter another user ID for the current user
ID has been applied.
2 rapid beeps The user ID is valid, wait for swiping.
When adding cards continuously, different beeps stand for
different meanings.
Sound Description
Prompt
1 beep Swipe the card.
5 slow beeps The card is failed to be added for it has been
registered.
3 slow beeps The user ID exists.
2 rapid beeps The card is successfully added.
12
Access Control Terminal·User Manual
Delete User
Two ways are allowed to delete the user: swiping card, and
entering user ID
 Swiping card:
[02] +[swipe the card]+[#]
 Entering user ID:
[02] +[4-bit code]+[#]
Swipe the card and enter “#” after the buzzer buzzes one beep.
Sound Description
Prompt
3 slow beeps The operation of deleting card is failed.
2 rapid beeps The operation of deleting card is
successful.
Enter the user ID and enter “#”.
Sound Description
Prompt
3 slow beeps The operation of deleting card is failed.
2 rapid beeps The operation of deleting card is
successful.

Authentication Mode:
Command:
[03] + [data 1] + [#]

the value of data 1 can be 0 or 1.


Value Description
1 Card + Password
0 Card only
Other values Failed

13
Access Control Terminal·User Manual
Access Parameters:
Command:
[04] + [data 1]+ [data 2] +[data 3]+ [data 4] +[#]
 Data 1 is a 3-bit value, ranging from 001 to 255, and stands
for the door open time;
 Data 2 is a 2-bit value, ranging from 00 to 99, and stands for
the door open timeout;
 Data 3 is a 1-bit value, and stands for door magnetic type: 0-
normally close, and 1- normally open.
 Data 4 is a 1-bit value, and stands for the button type:
0-normally close, and 1- normally open.
Sound Description
Prompt
3 slow beeps The operation of editing the access
parameters is failed.
2 rapid beeps The operation of editing the access
parameters is successful.

Super Password:
Command:
[05] + [8-bit super password] + [8-bit super password] +[#]
Sound Description
Prompt
3 slow beeps The operation of editing the super
password is failed.
2 rapid beeps The operation of editing the super
password is successful.

If the 8-bit super password is set as 00000000, which means the


super password is disabled.
14
Access Control Terminal·User Manual
Enable Controller:
Command:
[06]+ [data 1] + [data 2] +[#]
Member Length Function Description
Data 1 1 bit Whether to enable the 0-disable;
key sound 1-enable
Data 2 1 bit Whether to enter the 0-no, 1-yes
card No. by keypad

Sound Prompt Description


3 slow beeps The operation is failed.
2 rapid beeps The operation is successful.

Clear Card:
Command:
[07]+ [5-bit programming password]+[#]
Sound Prompt Description
3 slow beeps The operation of clearing card is failed.
2 rapid beeps The operation of clearing card is
successful. And after 1 second, the
controller starts deleting all cards.

15
Access Control Terminal·User Manual
Restore Default Settings:
Command:
[08]+ [5-bit programming password]+[#]
Sound Prompt Description
3 slow beeps The operation of restoring default
settings is failed.
2 rapid beeps The operation of restoring default
settings is successful. And after 5
seconds, the controller starts restoring
the factory settings.

Reboot the Device:


Command:
[09]+ [5-bit programming password]+[#]
Sound Prompt Description
3 slow beeps The operation of rebooting is failed.
2 rapid beeps The operation of rebooting is successful.
And after 1 second, the controller starts
rebooting.

In the programming mode, the buzzer buzzes two beeps and the
controller is switched to the normal mode after no operation for
30 seconds.