Calcul Hala Metalica Disciplina Metal II PDF Free
Calcul Hala Metalica Disciplina Metal II PDF Free
Calcul Hala Metalica Disciplina Metal II PDF Free
Date de proiectare:
n 22
L 1800 cm 10 n cm 20.2 m
H 450cm 5 n cm 5.6 m
T 5.2m
nt 7
7deg
L
h tan ( ) 1.24 m
2
h 1.25m
kN
s k 1.5 Is 1 Ce 1 i 0.8 Ct 1
2
m
kN
s s k Is Ce Ct i 1.2
2
m
Ht H h 6.85 m
pe verticala-directia x
g Iw 1 q b 0.4kPa
we g Iw cpe q p ze
3
b 20.2m d 36.4m
ze Ht Ht
0.188
d
e min b 2 Ht 13.7 m
2 2
q p ( z) cpq c0 cr q b z0 0.3m zmin 5m
1
2
c0 1 kr 0.214 kr 0.046 b 2.35
cr kr ln
H
0.626 g 3.5
z0
2.35
Ivz 0.321
2.5 ln
H
z0
cpq 1 2 g Ivz 3.248
2 2
q p cpq c0 cr q b 0.51 kPa
cpe.A 1.2
wxA g Iw cpe.A q p 0.612 kPa
cpe.B 0.8
wxB g Iw cpe.B q p 0.408 kPa
cpe.C 0.5
wxC g Iw cpe.C q p 0.255 kPa
cpe.D 0.7
wxD g Iw cpe.D q p 0.357 kPa
cpe.E 0.3
wxE g Iw cpe.E q p 0.153 kPa
Ht
ze Ht 0.339
d
e min b 2 Ht 13.7 m
cpe.A 1.2
wyA g Iw cpe.A q p 0.612 kPa
cpe.B 0.8
wyB g Iw cpe.B q p 0.408 kPa
cpe.C 0.5
wyC g Iw cpe.C q p 0.255 kPa
0.25 0.8
hd cpe
1 0.7
2
cpe.D linterp ( hd cpe 0.339) 0.788
0.25 0.5
hd cpe
1 0.3
cpe.E linterp ( hd cpe 0.339) 0.476
Pentru acoperis
pe directia x
b 36.4m d 20.2 m
e min b 2 Ht 13.7 m
Ht
ze Ht 0.339
d
Ht
cr kr ln 0.669
z0
2.35
Ivz 0.3
Ht
2.5 ln
z0
cpq 1 2 g Ivz 3.103
A 4.69
2 2
q p cpq c0 cr q b 0.556 kPa
5 2.5
gr val
15 2.0
cpe1 linterp ( gr val 7) 2.4
5 1.7
gr val
15 0.9
cpe10 linterp ( gr val 7) 1.54
cpe cpe1 cpe10 cpe1 log ( A ) 1.823
wxFs g Iw cpe q p 1.014 kPa
3
5 0
gr val
15 0.2
cpe10 linterp ( gr val 7) 0.04
5 1.2
gr val
15 0.8
cpe10 linterp ( gr val 7) 1.12
wxGs g Iw cpe10 q p 0.623 kPa
5 0
gr val
15 0.2
cpe10 linterp ( gr val 7) 0.04
wxGp g Iw cpe10 q p 0.022 kPa
5 0.6
gr val
15 0.3
cpe10 linterp ( gr val 7) 0.54
5 0
gr val
15 0.2
cpe10 linterp ( gr val 7) 0.04
wxHp g Iw cpe10 q p 0.022 kPa
5 0.6
gr val
15 1.0
cpe10 linterp ( gr val 7) 0.68
5 0.2
gr val
15 0
cpe10 linterp ( gr val 7) 0.16
wxJp g Iw cpe10 q p 0.089 kPa
5 0.6
gr val
15 0.4
4
cpe10 linterp ( gr val 7) 0.56
5 0.6
gr val
15 0
cpe10 linterp ( gr val 7) 0.48
pe directia y
d 36.4m
b 20.2m
e min b 2 Ht 13.7 m
Ht
ze Ht 0.188
d
Ht
cr kr ln 0.669
z0
2.35
Ivz 0.3
Ht
2.5 ln
z0
cpq 1 2 g Ivz 3.103
A 4.69
2 2
q p cpq c0 cr q b 0.556 kPa
5 2.5
gr val
15 2.0
cpe1 linterp ( gr val 7) 2.4
5 1.7
gr val
15 0.9
cpe10 linterp ( gr val 7) 1.54
cpe cpe1 cpe10 cpe1 log ( A ) 1.823
wyFs g Iw cpe q p 1.014 kPa
5
5 0
gr val
15 0.2
cpe10 linterp ( gr val 7) 0.04
A 9.14
2 2
q p cpq c0 cr q b 0.556 kPa
5 2.0
gr val
15 1.5
cpe1 linterp ( gr val 7) 1.9
5 1.2
gr val
15 0.8
cpe10 linterp ( gr val 7) 1.12
cpe cpe1 cpe10 cpe1 log ( A ) 1.15
wyGs g Iw cpe q p 0.64 kPa
5 0
gr val
15 0.2
cpe10 linterp ( gr val 7) 0.04
5 0.6
gr val
15 0.3
cpe10 linterp ( gr val 7) 0.54
5 0
gr val
15 0.2
cpe10 linterp ( gr val 7) 0.04
wyHp g Iw cpe10 q p 0.022 kPa
5 0.6
gr val
15 0.4
cpe10 linterp ( gr val 7) 0.56
6
wyIs g Iw cpe10 q p 0.312 kPa
5 0.6
gr val
15 0
cpe10 linterp ( gr val 7) 0.48
wesv min wxA wxBwxCwxD wxEwyA wyBwyCwyD wyE 0.612 kPa
wesa min wxFs wxFp wxGs wxGp wxHs wxHp wxJs wxJp wxIs wx2Is wyFs wyFp wyGs wyGp wyHs wyHp wyIs wy2Is 1.014 kPa
wepa max wxFs wxFp wxGs wxGp wxHs wxHp wxJs wxJp wxIs wx2Is wyFs wyFp wyGs wyGp wyHs wyHp wyIs wy2Is 0.089 kPa
s 1.2 kPa
Alegerea panourilor
wesa 1.014 kPa
wepa 0.089 kPa
2
2 L
L' h 2 10.177 m
L' 10.20m
aleg :
kN
d pan 10cm mp 0.1234
2
m
mpanou mp T L 2 25.924 kN
7
KS1000RW pt acoperis
kN
Pp 1.5 wepa 0.134
2
m
kN -la o deschidere de 3 m;
Sp 1.5 wesa 1.521
2
m
aleg :
d pan 0.1 m
KS1000RW pt pereti
mpanou.2 mp T H 2 7.187 kN
Dimensionarea panelor
-aleg Z120/1.5+1.5+Z120/1.5
kN kN
Pr 1.83 Sr 1.89
2 2
m m
2
A pana 338mm
kN
Gpana 0.028
m
-alegerea profilelor C
kN
kN kN g c 0.02
Pc 0.77 Sc 0.918 m
2 2
m m
8
Forta taietoare de baza:
ag 0.15g
u
0 2.5 1.15 CT 0.085
1
3
4
T1p CT 6.85 0.36 s
0 m m
Sd ag 0.914 > 0.2 ag 0.294
q 2 2
s s
Ie 1
1
Fb Ie Sd m
kN kN
g s 0.88 g g 1.22
m m
ms 2g s H 9.856 kN
mg 2 g g L' 24.888 kN
Fb Ie Sd m 12.948 kN
9
Verificari structurale
Efectul imperfectiunilor:
1
0
200 Ht 6.85 m
2
h
6.85
0.5 1
1
m
2
3
0 h m 3.309 10
Stalp [HE300A] reducem sectiunea din considerente economice aleg [HEA260] - caracteristici
sectionale:
2 2
h s 250mm A s 86.8 10 mm
b s 260mm h is 225mm
4 4 4 4
Iy 10450 10 mm Iz 3668 10 mm
3 3 3 3
W el.y 836.4 10 mm W el.z 282.1 10 mm
3 3 3 3
W pl.y 919.8 10 mm W pl.z 430.2 10 mm
4 4
It 52.37 10 mm
9 6
2 2 Iw 516.4 10 mm
A vz 28.76 10 mm
Verificarea propriu-zisa:
-din infasuratoare ne rezulta momentul maxim si N si T aferent, deasemenea Mmax rezulta din
combinatia 6;
Mmax 240.61kN m
10
-combinatia 6 ne da momentul maxim si fortele axiale si taietoare maxime deci vom folosi la
dimensionarea si verificarea elementelor structurale;
Med 240.61kN m
M2 1.25
M0 1.00
M1 1.00
N N 235
fy 275 fu 430 s 0.924
2 2 275
mm mm
cs d s 0.177 m
Ned
d N 0.067 m
t ws fy
ds d N
s 0.689 s 0.50 1
2 d s
cs cs 396 s
23.6 1 -clasa 1
t ws t ws 13 1
-pentru talpa;
b s tws
cst 0.126 m
2
tfs 0.013 m
cst
10.1
t fs
cst 9 s cst 9 s
1 1 -clasa 1;
t fs t fs
11
=> alegem clasa 1:
1 A vz h is tws 1
fy
A vz
3
Vpl.Rd 456.626 kN
M0
Efort Axial;
A s fy 3
Npl.Rd 2.387 10 kN
M0 Npl.Rd.s Npl.Rd
Ned Npl.Rd 1
0.5 h is t ws fy
Ned 1
M0
Moment incovoietor:
W pl.y fy
Mpl.y.Rd 252.945 kN m
M0
Med Mpl.y.Rd 1
Verificarea de stabilitate-stalp
-determinarea lungimilor si coeficientilor de flambaj
12
4 4
Iygr 33740 10 mm
4 4
Iyst Iy 1.045 10 cm
Iygr Lst
k 1.773 -stalpul incastrat in fundatie=>
Lgr Iyst
N
y 1.09816 Lcry y Lst Es 210000 Gs 0.4 Es
2
mm
2
Es Iyst 3
Ncry 5.727 10 kN
2
Lcry
A s fy
y 0.646
Ncry
hs
0.962 tfs 12.5 mm y 0.21 -curba c;
bs =>
y 0.5 1 y y 0.2 y
2
0.755
1
y 0.872
2 2
y y y
Izst Iz
2
Es Izst 3
Ncrz 2.424 10 kN
2
Lcrz
A s fy
z 0.992
Ncrz
hs
0.962 tfs 12.5 mm z 0.34 -curba b;
bs =>
13
-pt flambaj lateral"
Lcr.lat Lst
M1 240.61kN m M2 133.03kN m
M2
y 0.553 => C1 2.06
M1
4 4
Iwst Iw Itst 85.17 10 mm
2 2
C1 Es Izst Iwst Lcr.lat Gs Itst 3
Mcr.lat 1.043 10 kN m
2 Izst 2
Lcr.lat Es Izst
hs
0.962 =>curba de flambaj c; lat 0.49
bs
W pl.y fy
lat 0.493
Mcr.lat
1
lat 0.847
2 2
lat lat lat
Ned Ned
1 1
Ncry Ncrz
y 0.997 z 0.977
Ned Ned
1 y 1 z
Ncry Ncrz
W pl.y
y 1.1 W pl.z
W el.y z 1.525 => limitam la 1,5 =>
W el.z z 1.5
Ned Itst 3
pl 0.058 alat 8.15 10
Npl.Rd.s Iyst
4 4
I0st Iyst Izst 1.412 10 cm
14
As 2 Iwst
Ncrt Gs Itst Es 6.497 103 kN
I0st
Lcr.lat
2
o 1 => C1 1
pt calculul lui λ.o vom considera
2
Es Izst I Lcr.lat Gs Itst
2
wst
Mcr0 1 506.135 kN m
2 Izst 2
Lcr.lat Es Izst
W pl.y fy
0 0.707 Ncrtf Ncrt -pt o sectiune dublu simetrica
Mcr0
4
Npl.Rd.s Npl.Rd.s
0 0.2 C1 1 1 1 => folosim al doilea set de formule
Ncrz Ncrtf
Ned
Cmy0 0.79 0.2 y 0.36 y 0.33
Ncry
0.672
Med As
y 18.134
Ned W el.y
y alat
Cmy Cmy0 1 Cmy0 0.683
1 y alat
2 alat 3
Cmlat Cmy 3.955 10
Ned Ned
1 N 1
Ncrt
crz
Cmlat 1 1 Cmlat 1
Medz 0
d lat 0 b lat 0
max max y z 0.992
15
W el.y
Cyy 1
W pl.y
Cmy max
2 2
Czy 1 y 1 1 2 14 d 1.088
5 pl lat
y
y W el.y
Czy 0.6 1
z W pl.y
-factori de interactiune
y 1
kyy Cmy Cmlat 0.695
Ned Cyy
1
Ncry
z 1 y
kzy Cmy Cmlat 0.6 0.323
Ned Czy z
1
Ncry
-verificarea de stabilitate
Ned Med
kyy 0.846
y Npl.Rd.s lat Mpl.y.Rd (daca reduc sectiunea de la HEA260 la HEA 240 nu imi mai
rezulta verificarea)
Ned Med
kzy 0.458
z Npl.Rd.s lat Mpl.y.Rd
Grinda [IPE 600]-reducem sectiunea grinzii din considerente economice[IPE 450]-caracteristici sectionale:
2 2
h p 450mm A p 98.8 10 mm
b p 190mm h ip 420.8mm
2 2
A vz.p 50.9 10 mm
16
3 3 3 3
W el.y.p 1500 10 mm W el.z.p 176 10 mm
3 3 3 3
W pl.y.p 1702 10 mm W pl.z.p 276 10 mm
4 4
Iyp 33740 10 mm
4 4
Izp 1676 10 mm
4 4
Itp 66.9 10 mm
9 6
Iwp 791 10 mm
Verificarea propriu-zisa:
-din infasuratoare ne rezulta momentul maxim si N si T aferent, deasemenea Mmax rezulta din
combinatia 6;
Mmax.p 311.16kN m
-combinatia 6 ne da momentul maxim si fortele axiale si taietoare maxime deci vom folosi la
dimensionarea si verificarea elementelor structurale;
Med.p 311.16kN m
Ved.p 111.85kN
Ned.p 81.07kN
cp d p 0.379 m
Ned.p
d N 0.038 m
twp fy
dp dN
p 0.55 s 0.50 1
2 d p
cp cp 396 s
40.298 1 -clasa 1
t wp t wp 13 1
17
-pentru talpa;
b p twp
cpt 0.09 m
2
tfp 0.015 m
cpt
6.185
tfp
cpt 9 s cpt 9 s
1 1 -clasa 1;
tfp tfp
=> alegem clasa 1 pentru ca daca verifica la clasa 1 va verifica la toate clasele mai inferioare;
1 A vz.p h ip t wp 1
fy
A vz.p
3
Vpl.Rd.p 808.146 kN
M0
Efort Axial;
A p fy 3
Npl.Rd.p 2.717 10 kN
M0
Ned.p Npl.Rd.p 1
0.5 h ip twp fy
Ned.p 1
M0
18
Moment incovoietor:
W pl.y.p fy
Mpl.y.Rd.p 468.05 kN m
M0
M ed.p
Med.p Mpl.y.Rd.p 1 0.665
M pl.y.Rd.p
Verificarea de stabilitate-grinda
-determinarea lungimilor si coeficientilor de flambaj
2
Es Iyp 3
Ncry 6.721 10 kN
2
Lcry
A p fy
y 0.636
Ncry
hp
2.368 tfp 14.6 mm y 0.21 -curba a;
bp =>
y 0.5 1 y y 0.2 y
2
0.748
1
y 0.876
2 2
y y y
2
Es Izp
Ncrz 333.882 kN
2
Lcrz
A p fy
z 2.853
Ncrz
hp
2.368 tfp 14.6 mm z 0.34 -curba b;
bp =>
19
z 0.5 1 z z 0.2 z 5.02
2
1
z 0.109
2 2
z z z
M1 311.16kN m M2 216.28kN m
M2
y 0.695 => C1 1.913
M1
2 2
C1 Es Izp Iwp Lcr.lat Gs Itp
Mcr.lat 296.509 kN m
2 Izp 2
Lcr.lat Es Izp
W pl.y.p fy
lat 1.256
Mcr.lat
1
lat 0.495
2 2
lat lat lat
Ned.p Ned.p
1 1
Ncry Ncrz
y 0.998 z 0.73
Ned.p Ned.p
1 y 1 z
Ncry Ncrz
W pl.y.p
y 1.135 W pl.z.p
W el.y.p z 1.568 => limitam la 1,5 =>
W el.z.p z 1.5
20
Ned.p Itp 3
pl 0.036 alat 1.983 10
Npl.Rd.p Iyp
4 4
I0p Iyp Izp 3.542 10 cm
Ap 2 Es Iwp
Ncrt Gs Itp 2.007 103 kN
I0p
Lcr.lat
2
o 1 => C1 1
pt calculul lui λ.o com considera
2
Es Izp I Lcr.lat Gs Itp
2
wp
Mcr0 1 154.997 kN m
2 Izp 2
Lcr.lat Es Izp
W pl.y.p fy
0 1.738 Ncrtf Ncrt -pt o sectiune dublu simetrica
M cr0
4
Npl.Rd.p Npl.Rd.p
0 0.2 C1 1 1 1 => folosim al doilea set de formule
Ncrz Ncrtf
Ned.p
Cmy0 0.79 0.2 y 0.36 y 0.33
Ncry
0.646
Med.p Ap
y 20.946
Ned.p W el.y.p
y alat
Cmy Cmy0 1 Cmy0 0.649
1 y alat
2 alat 3
Cmlat Cmy 1.018 10
Ned.p Ned.p
1 N 1 N
crz crt
Cmlat 1 1 Cmlat 1
max max y z 2.853
21
Cyy 1 y 1 2 Cmy max pl b lat 0.978
1.6 1.6
y
2
Cmy max
y
2 2
W el.y.p
Cyy 1
W pl.y.p
2
Cmy max
2
Czy 1 y 1 1 2 14 d 1.021
5 pl lat
y
y W el.y.p
Czy 0.6 1
z W pl.y.p
-factori de interactiune
y 1
kyy Cmy Cmlat 0.672
Ned.p Cyy
1
Ncry
z 1 y
kzy Cmy Cmlat 0.6 0.246
Ned.p Czy z
1
Ncry
-verificarea de stabilitate M1 1
Ned.p Med.p
kzy 0.659 Ned.p Med.p
z Npl.Rd.p kzy 11
lat Mpl.y.Rd.p z Npl.Rd.p lat Mpl.y.Rd.p
22
Dimensionare contravantuiri
-din programul de calcul static sap am obtinut prin incarcarea structurii din vant si seism contravantuire de
tip tirant care lucreaza doar la intindere
Nedc 36.87kN
Nedc 2
A nec 1.341 cm
fy
2
A seff 1.54cm
-aleg dispunerea contravantuirilor de ϕ14
fy
Nrd A seff 42.35 kN Nedc
1 0.871
Nrd
-din programul de calcul static sap am obtinut prin incarcarea structurii din vant si seism
contravantuire de tip grinda cu zabrele
Nedc 49.53kN
Nedc 2
A nec 1.801 cm
fy
2
A seff 2.01cm
-aleg dispunerea contravantuirilor de ϕ16
fy
Nrd A seff 55.275 kN Nedc
1 0.896
Nrd
Ned 48.26kN
lcr T 5.2 m
23
-verificare la flambaj a tevii
aleg teava circulara cu R55*
2
d 3 2
d 55mm A b 2.376 10 mm
4
4
d 5 4
Ib 8.984 10 mm
32
2
Es Ib
Ncrb 68.859 kN
2
lcr
A b fy
3.08
Ncrb
0.49 -curba c;
0.5 1 ( 0.2)
2
5.95
1
0.091
2 2
fy
Nrd A b 59.18 kN
1
Ned
0.815
Nrd
24