This paper introduces and compares the various techniques for identification and analysis of low ... more This paper introduces and compares the various techniques for identification and analysis of low frequency oscillations in a power system. Inter-area electromechanical oscillations are the focus of this paper. After multiresolution decomposition of characteristic signals, physical characteristics of system oscillations in signal components are identified and presented using the Fourier transform, Prony’s method, Matrix Pencil Analysis Method, S-transform, Global Wavelet Spectrum and Hilbert Huang transform (Hilbert Marginal Spectrum) in time-frequency domain representation. The analyses were performed on real frequency signals obtained from FNET/GridEye system during the earthquake that triggered the shutdown of the North Anna Nuclear Generating Station in the east coast of the United States. In addition, according to the obtained results the proposed methods have proven to be reliable for identification of the model parameters of low-frequency oscillation in power systems. The rele...
This paper specifies and compares the ancillary services used by transmission system operators in... more This paper specifies and compares the ancillary services used by transmission system operators in selected countries within ENTSO-E (European Network of Transmission System Operators-Electricity) for operational needs of their transmission systems. The comparison of the ancillary services’ unit prices is also given. In addition, analyses of various experiences gained by ENTSO-E countries within their electric power systems in relation to initiatives supporting the power generation from renewable energy sources (RES) and the methods of their integration into the electric power system were made. Namely, depending on the total amount of RES, depending on the incentive system for electricity production from RES and the development of an organized electricity market, different balancing responsibility models for electricity producers from RES were established.
The data include the results of measurements of the impedance spectrum of: - Bronze (Figure 3 a) ... more The data include the results of measurements of the impedance spectrum of: - Bronze (Figure 3 a) and Bronze with sulfide patina and two coating layers (Figure 3 b) in 3.5% aqueous sodium chloride solution, tap water and paste electrolyte. - Sulfide patinated bronze with one (1L), two (2L) and three coating layers (3L) (Figure 5a). - The four types of artificial patina on bronze without (Figure 6 a) and with (Figure 6 b) two coating layers. - Artificial sulfide patina on bronze with a single coating that has been mechanically damaged (Figure 7 a). - Artificial sulfide patina on bronze which has been mechanically damaged (Figure 8 a) - Bronze coins in the untouched state (Figure 9 a) and with a single layer of coating (Figure 9b).
2017 2nd International Multidisciplinary Conference on Computer and Energy Science (SpliTech), 2017
This paper deals with investigation of the impulse characteristics of transmission line tower gro... more This paper deals with investigation of the impulse characteristics of transmission line tower grounding. Investigations of the impulse characteristics of transmission lines tower grounding in this paper are based on experimental analysis conducted on type “A” grounding of transmission line tower. Firstly, paper describes the problem of back-flashover and impact of transmission lines tower grounding impedance on it. Also, experimental investigation of impulse characteristics with different rise time of current wave front on real type “A” grounding are given. Finally, detail analysis of experimental data is given.
The use of renewable energy sources increases the energy self-sustainability of cities, enabling ... more The use of renewable energy sources increases the energy self-sustainability of cities, enabling citizens to reduce energy costs, which results in an increase in their standard of living. However, solar energy penetration in Bosnia and Herzegovina, and its capital Sarajevo, is not in line with the possibilities. Furthermore, the Sarajevo Canton is extremely polluted during the winter months because of the use of unacceptable heating fuel. The aim of this paper is to introduce photovoltaic power systems use in heating electrification system. In this paper AQI is calculated based on historical data and the hybrid model EMD-SARIMA for air pollution and a solar production forecast is presented. The methodology was tested in the Sarajevo Canton, taking into account 35,000 households. In order to ensure clean air, renewable electric energy use for household heating should be implemented. The widespread use of inefficient individual heating systems characterized by inefficient and expensiv...
2012 International Conference and Exposition on Electrical and Power Engineering, 2012
Grounding systems have the most important role in safety of staff and substation equipment and th... more Grounding systems have the most important role in safety of staff and substation equipment and therefore they require detailed analysis of relevant parameters. This paper discusses the possibility of application of software packages based on finite element method (FEM), when conducting analysis of grounding systems. Firstly the paper describes a mathematical model with assumptions on which is based. Complex grounding grids buried in both single-layer and double-layer soil where analyzed. In order to verify the presented model, calculation results are compared with results of various analytical and numerical methods, as well as with measured results. Finally to show the practical application of this approach, an example of a real grounding grid is calculated.
Engineering, Technology & Applied Science Research
In order to decide the appropriate arrangements of fictitious charges in the charge simulation me... more In order to decide the appropriate arrangements of fictitious charges in the charge simulation method, the use of the Monte Carlo method is proposed for the estimation of the probability density function of two variables, the radius ratio, and the angle ratio. Τhe scale and shape parameters of the Weibull's distribution are determined by the maximum likelihood estimator. The obtained results are used to calculate the electric field at arbitrary points in the neighborhood of high voltage transmission lines. The comparisons between the results computed by this method, the results calculated by the genetic algorithm, and those measured, confirm the effectiveness and accuracy of the proposed method.
This paper considers the application of machine learning models to electric field intensity and m... more This paper considers the application of machine learning models to electric field intensity and magnetic flux density estimation in the proximity of the overhead transmission lines. The machine learning models are applied on two horizontal overhead transmission line configurations at different rated voltages, at height 1 m above ground surface. The obtained results are compared with the results obtained by charge simulation method and Biot-Savart law based method as well as with the field measurement results.
Cathodic protection system is commonly employed approach for the protection of the metallic infra... more Cathodic protection system is commonly employed approach for the protection of the metallic infrastructure placed in electrolyte against corrosion. Adequate design of the cathodic protection system requires the determination of electrical potential and current density distribution on the protected object surface that meets the defined criteria. In this paper, the application of the direct boundary element method in conjunction with Newton-Raphson method was considered for the calculation of the electric potential and current density distribution on the surface of the cathodically protected underground object. The considered method was applied on the sacrificial anode cathodic protection system of the underground pipeline. The non-linear boundary conditions of the electrode surfaces of the cathodic protection system are taken into account. The method was used to determine the current density and electric potential distribution on the external wall of the protected pipeline.
This paper introduces and compares the various techniques for identification and analysis of low ... more This paper introduces and compares the various techniques for identification and analysis of low frequency oscillations in a power system. Inter-area electromechanical oscillations are the focus of this paper. After multiresolution decomposition of characteristic signals, physical characteristics of system oscillations in signal components are identified and presented using the Fourier transform, Prony’s method, Matrix Pencil Analysis Method, S-transform, Global Wavelet Spectrum and Hilbert Huang transform (Hilbert Marginal Spectrum) in time-frequency domain representation. The analyses were performed on real frequency signals obtained from FNET/GridEye system during the earthquake that triggered the shutdown of the North Anna Nuclear Generating Station in the east coast of the United States. In addition, according to the obtained results the proposed methods have proven to be reliable for identification of the model parameters of low-frequency oscillation in power systems. The rele...
This paper specifies and compares the ancillary services used by transmission system operators in... more This paper specifies and compares the ancillary services used by transmission system operators in selected countries within ENTSO-E (European Network of Transmission System Operators-Electricity) for operational needs of their transmission systems. The comparison of the ancillary services’ unit prices is also given. In addition, analyses of various experiences gained by ENTSO-E countries within their electric power systems in relation to initiatives supporting the power generation from renewable energy sources (RES) and the methods of their integration into the electric power system were made. Namely, depending on the total amount of RES, depending on the incentive system for electricity production from RES and the development of an organized electricity market, different balancing responsibility models for electricity producers from RES were established.
The data include the results of measurements of the impedance spectrum of: - Bronze (Figure 3 a) ... more The data include the results of measurements of the impedance spectrum of: - Bronze (Figure 3 a) and Bronze with sulfide patina and two coating layers (Figure 3 b) in 3.5% aqueous sodium chloride solution, tap water and paste electrolyte. - Sulfide patinated bronze with one (1L), two (2L) and three coating layers (3L) (Figure 5a). - The four types of artificial patina on bronze without (Figure 6 a) and with (Figure 6 b) two coating layers. - Artificial sulfide patina on bronze with a single coating that has been mechanically damaged (Figure 7 a). - Artificial sulfide patina on bronze which has been mechanically damaged (Figure 8 a) - Bronze coins in the untouched state (Figure 9 a) and with a single layer of coating (Figure 9b).
2017 2nd International Multidisciplinary Conference on Computer and Energy Science (SpliTech), 2017
This paper deals with investigation of the impulse characteristics of transmission line tower gro... more This paper deals with investigation of the impulse characteristics of transmission line tower grounding. Investigations of the impulse characteristics of transmission lines tower grounding in this paper are based on experimental analysis conducted on type “A” grounding of transmission line tower. Firstly, paper describes the problem of back-flashover and impact of transmission lines tower grounding impedance on it. Also, experimental investigation of impulse characteristics with different rise time of current wave front on real type “A” grounding are given. Finally, detail analysis of experimental data is given.
The use of renewable energy sources increases the energy self-sustainability of cities, enabling ... more The use of renewable energy sources increases the energy self-sustainability of cities, enabling citizens to reduce energy costs, which results in an increase in their standard of living. However, solar energy penetration in Bosnia and Herzegovina, and its capital Sarajevo, is not in line with the possibilities. Furthermore, the Sarajevo Canton is extremely polluted during the winter months because of the use of unacceptable heating fuel. The aim of this paper is to introduce photovoltaic power systems use in heating electrification system. In this paper AQI is calculated based on historical data and the hybrid model EMD-SARIMA for air pollution and a solar production forecast is presented. The methodology was tested in the Sarajevo Canton, taking into account 35,000 households. In order to ensure clean air, renewable electric energy use for household heating should be implemented. The widespread use of inefficient individual heating systems characterized by inefficient and expensiv...
2012 International Conference and Exposition on Electrical and Power Engineering, 2012
Grounding systems have the most important role in safety of staff and substation equipment and th... more Grounding systems have the most important role in safety of staff and substation equipment and therefore they require detailed analysis of relevant parameters. This paper discusses the possibility of application of software packages based on finite element method (FEM), when conducting analysis of grounding systems. Firstly the paper describes a mathematical model with assumptions on which is based. Complex grounding grids buried in both single-layer and double-layer soil where analyzed. In order to verify the presented model, calculation results are compared with results of various analytical and numerical methods, as well as with measured results. Finally to show the practical application of this approach, an example of a real grounding grid is calculated.
Engineering, Technology & Applied Science Research
In order to decide the appropriate arrangements of fictitious charges in the charge simulation me... more In order to decide the appropriate arrangements of fictitious charges in the charge simulation method, the use of the Monte Carlo method is proposed for the estimation of the probability density function of two variables, the radius ratio, and the angle ratio. Τhe scale and shape parameters of the Weibull's distribution are determined by the maximum likelihood estimator. The obtained results are used to calculate the electric field at arbitrary points in the neighborhood of high voltage transmission lines. The comparisons between the results computed by this method, the results calculated by the genetic algorithm, and those measured, confirm the effectiveness and accuracy of the proposed method.
This paper considers the application of machine learning models to electric field intensity and m... more This paper considers the application of machine learning models to electric field intensity and magnetic flux density estimation in the proximity of the overhead transmission lines. The machine learning models are applied on two horizontal overhead transmission line configurations at different rated voltages, at height 1 m above ground surface. The obtained results are compared with the results obtained by charge simulation method and Biot-Savart law based method as well as with the field measurement results.
Cathodic protection system is commonly employed approach for the protection of the metallic infra... more Cathodic protection system is commonly employed approach for the protection of the metallic infrastructure placed in electrolyte against corrosion. Adequate design of the cathodic protection system requires the determination of electrical potential and current density distribution on the protected object surface that meets the defined criteria. In this paper, the application of the direct boundary element method in conjunction with Newton-Raphson method was considered for the calculation of the electric potential and current density distribution on the surface of the cathodically protected underground object. The considered method was applied on the sacrificial anode cathodic protection system of the underground pipeline. The non-linear boundary conditions of the electrode surfaces of the cathodic protection system are taken into account. The method was used to determine the current density and electric potential distribution on the external wall of the protected pipeline.
Uploads
Papers by Adnan Mujezinovic