Abstract The proposed Smart Health Monitoring Glove is an interdisciplinary system, which is desi... more Abstract The proposed Smart Health Monitoring Glove is an interdisciplinary system, which is designed keeping in view to track internal body changes. It is based on implementation of biggest innovation in technology- the wearable technology using Node Microcontroller Unit (MCU) which is known for their simultaneous operation and display of necessary information on the patient. This cost effective device uses a pulse sensor to track patient’s pulse rate, while the Max 30102 sensor is used to measure the temperature and blood oxygen level in the body. The sensors are mounted on the glove along with the display. The sensor based monitoring system sends information to the Node MCU used which then processes it and further sends a command to the display module. In addition to this a Wi-Fi module is placed on the glove which when connected to a mobile application - Blynk, displays the complete information of the patient and further stores this information in a database- accessible to doctor as well as the patient. Keywords: Wearable Technologies, Pulse Sensors, sensor based monitoring, Wi-Fi module, mobile application. Cite this Article Raashi Bhutani, Abhishek Gandhar, Saurabh Yadav, Shivam Mittal, Arvind Rehalia, Tushar Dhankhar. Smart Health Monitoring Glove. Journal of Instrumentation Technology & Innovations. 2020; 10(2): 19–23p.
Journal of instrumentation technology & innovations, Sep 26, 2013
Cardiac arrhythmia causes substantial morbidity and mortality; even with optimal pharmacotherapy ... more Cardiac arrhythmia causes substantial morbidity and mortality; even with optimal pharmacotherapy Cardiac pace maker and pulse meter has been instrumental in saving the life of mankind. The knowledge of basic concepts, application, types, and complications is essential for the medical and engineering professionals. Advances in the electronic circuitry and the battery have led to the development of safe, efficient and effective cardiac pace maker devices. The linking of pace maker and pulse meter is a challenging task for the bio medical engineers. Our systematic review summarizes the current evidence regarding the efficacy, effectiveness, safety and electronic perspective of cardiac pace maker and pulse meter. Keywords: P acemaker, pulse meter, cardiac arrythmia
Journal of Information and Optimization Sciences, Jan 2, 2022
Abstract Presently, the brain signals are recorded by the various techniques like MRI, FMRI, CT S... more Abstract Presently, the brain signals are recorded by the various techniques like MRI, FMRI, CT SCAN and EEG. Here we are using EEG technique to record the brain signals in this study. As it is a common technique used extensively for the detection of brain tumours. The motive behind this study is to examine the variations of the brain tumours. Here two different database of the EEG recordings are considered; Bern Barcelona (BB), and Bonn University (BU). The Butterworth filter is applied to take out the artifacts from the EEG signals. The decomposition technique is used to decompose the denoised EEG signals. This technique of decomposition helps to determine the necessary information, for the complete modeling of the multifarious time series data. This Fruitfly optimizer is used to extract the features from the main data signals. Finally, the data is classified into two different environments that is one being seizure and the other one is healthy. From the experimental simulation, proposed model has better accuracy in comparison, with the previous models. The significant improvement is observed in terms of accuracy is 5. 49%, sensitivity is 5%, specificity is 6% and positive predictive value is about 4 %.
Journal of Information and Optimization Sciences, Jan 2, 2022
Abstract A fractal antenna with triangular shape was introduced for Electromagnetic (EM) energy h... more Abstract A fractal antenna with triangular shape was introduced for Electromagnetic (EM) energy harvesting. Proposed antennas were designed at 10GHz using IE3D EM simulator software. Bandwidth plays very important role in wireless communication systems. More band width helps in collection of more energy from the atmosphere. Proposed multi band antenna of 0th iteration 9.8GHz, 15GHz and of 1st iteration 15.5GHz, 22GHz, 27GHz were achieved. Antennas with 0th and 1st iteration have 530MHz, 1220MHz and 410MHz, 1710MHz, 1820MHz respectively. The presented antenna can be very useful for radiofrequency (RF) energy harvesting system and can be used for many more applications.
International Journal of Modeling and Optimization, 2012
... www.embedtronics.com/nokia/fbus.html [7] Poverty in Numbers: The changing State from 2005 to ... more ... www.embedtronics.com/nokia/fbus.html [7] Poverty in Numbers: The changing State from 2005 to 2015, The Brookings Institution, Washington, DC, USA, January 2011, pp. 4. [8] Barriers and Gaps Affecting mHealth in Low and Middle Income Countries, Earth Institute, ...
ABSTRACT Rapid advances and developments in information technology and telecommunication have bro... more ABSTRACT Rapid advances and developments in information technology and telecommunication have brought in picture a promising technology, called mhealth, for delivery of health-care facilities via mobile communication technologies. For accelerating ...
Abstract The proposed Smart Health Monitoring Glove is an interdisciplinary system, which is desi... more Abstract The proposed Smart Health Monitoring Glove is an interdisciplinary system, which is designed keeping in view to track internal body changes. It is based on implementation of biggest innovation in technology- the wearable technology using Node Microcontroller Unit (MCU) which is known for their simultaneous operation and display of necessary information on the patient. This cost effective device uses a pulse sensor to track patient’s pulse rate, while the Max 30102 sensor is used to measure the temperature and blood oxygen level in the body. The sensors are mounted on the glove along with the display. The sensor based monitoring system sends information to the Node MCU used which then processes it and further sends a command to the display module. In addition to this a Wi-Fi module is placed on the glove which when connected to a mobile application - Blynk, displays the complete information of the patient and further stores this information in a database- accessible to doctor as well as the patient. Keywords: Wearable Technologies, Pulse Sensors, sensor based monitoring, Wi-Fi module, mobile application. Cite this Article Raashi Bhutani, Abhishek Gandhar, Saurabh Yadav, Shivam Mittal, Arvind Rehalia, Tushar Dhankhar. Smart Health Monitoring Glove. Journal of Instrumentation Technology & Innovations. 2020; 10(2): 19–23p.
Journal of instrumentation technology & innovations, Sep 26, 2013
Cardiac arrhythmia causes substantial morbidity and mortality; even with optimal pharmacotherapy ... more Cardiac arrhythmia causes substantial morbidity and mortality; even with optimal pharmacotherapy Cardiac pace maker and pulse meter has been instrumental in saving the life of mankind. The knowledge of basic concepts, application, types, and complications is essential for the medical and engineering professionals. Advances in the electronic circuitry and the battery have led to the development of safe, efficient and effective cardiac pace maker devices. The linking of pace maker and pulse meter is a challenging task for the bio medical engineers. Our systematic review summarizes the current evidence regarding the efficacy, effectiveness, safety and electronic perspective of cardiac pace maker and pulse meter. Keywords: P acemaker, pulse meter, cardiac arrythmia
Journal of Information and Optimization Sciences, Jan 2, 2022
Abstract Presently, the brain signals are recorded by the various techniques like MRI, FMRI, CT S... more Abstract Presently, the brain signals are recorded by the various techniques like MRI, FMRI, CT SCAN and EEG. Here we are using EEG technique to record the brain signals in this study. As it is a common technique used extensively for the detection of brain tumours. The motive behind this study is to examine the variations of the brain tumours. Here two different database of the EEG recordings are considered; Bern Barcelona (BB), and Bonn University (BU). The Butterworth filter is applied to take out the artifacts from the EEG signals. The decomposition technique is used to decompose the denoised EEG signals. This technique of decomposition helps to determine the necessary information, for the complete modeling of the multifarious time series data. This Fruitfly optimizer is used to extract the features from the main data signals. Finally, the data is classified into two different environments that is one being seizure and the other one is healthy. From the experimental simulation, proposed model has better accuracy in comparison, with the previous models. The significant improvement is observed in terms of accuracy is 5. 49%, sensitivity is 5%, specificity is 6% and positive predictive value is about 4 %.
Journal of Information and Optimization Sciences, Jan 2, 2022
Abstract A fractal antenna with triangular shape was introduced for Electromagnetic (EM) energy h... more Abstract A fractal antenna with triangular shape was introduced for Electromagnetic (EM) energy harvesting. Proposed antennas were designed at 10GHz using IE3D EM simulator software. Bandwidth plays very important role in wireless communication systems. More band width helps in collection of more energy from the atmosphere. Proposed multi band antenna of 0th iteration 9.8GHz, 15GHz and of 1st iteration 15.5GHz, 22GHz, 27GHz were achieved. Antennas with 0th and 1st iteration have 530MHz, 1220MHz and 410MHz, 1710MHz, 1820MHz respectively. The presented antenna can be very useful for radiofrequency (RF) energy harvesting system and can be used for many more applications.
International Journal of Modeling and Optimization, 2012
... www.embedtronics.com/nokia/fbus.html [7] Poverty in Numbers: The changing State from 2005 to ... more ... www.embedtronics.com/nokia/fbus.html [7] Poverty in Numbers: The changing State from 2005 to 2015, The Brookings Institution, Washington, DC, USA, January 2011, pp. 4. [8] Barriers and Gaps Affecting mHealth in Low and Middle Income Countries, Earth Institute, ...
ABSTRACT Rapid advances and developments in information technology and telecommunication have bro... more ABSTRACT Rapid advances and developments in information technology and telecommunication have brought in picture a promising technology, called mhealth, for delivery of health-care facilities via mobile communication technologies. For accelerating ...
Uploads
Papers by Arvind Rehalia