Positive margins after breast conservation surgery occur frequently and negatively influence loca... more Positive margins after breast conservation surgery occur frequently and negatively influence local control rates. Preoperative breast ultrasonography reduces the incidence of positive margins during breast conservation surgery. Case-control analysis. One hundred twenty-two consecutive patients with invasive breast cancer were studied. Palpation or needle-wire-guided breast conservation surgery was used in the first 61 patients (group 1). Preoperative breast ultrasonography was added to the protocol in the last 61 patients (group 2). Incidence of positive margins, distance to closest margin. There was a 3.7-fold reduction in positive margins (P =.04, 95% confidence interval, 1.06-16.73) and improved resection margins (P =.04, 95% confidence interval, 0.14-3.88) when breast ultrasonography was used. Reexcision of margins was done in 11% (7 of 61 patients) in group 1 and 3% (2 of 61 patients) in group 2 (P =.17). Preoperative breast ultrasonography improves the margins of resection and decreases the incidence of positive margins during breast conservation surgery.
Ultrasound is commonly used during diagnosis of breast lesions. Our purpose was to study the role... more Ultrasound is commonly used during diagnosis of breast lesions. Our purpose was to study the role of sonography for risk stratification of malignancy in the diagnosis and management of palpable breast cysts.This was a cohort study of 176 patients with palpable breast cysts. Sonographic findings were correlated with clinical and pathologic outcomes.Mean cyst size was 2.0 ± 1.8 cm. Cysts were simple, complex and probably benign, and complex and suspicious for neoplasm in 82.25%, 10.25% and 7.5% of patients, respectively. Thick cyst wall (P = 0.0001), mural tumor (P <0.00001), eccentric mass (P = 0.034), and internal septae (P = 0.031) were predictive of neoplasm. Of cysts >3 cm, 33% were cancerous (P = 0.000027). After 378 days of follow-up, 26 % of cysts had recurred. Recurrence was more frequent in patients with bilateral or multiple cysts (P = 0.004).Sonography is useful in risk stratification of malignancy in breast cysts. There is a high risk of recurrence after cyst aspiration.
Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to d... more Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to determine whether ultrasound-guided vacuum-assisted core biopsy (US-VACB) is safe and effective in completely removing presumed benign palpable breast masses. We conducted a cohort study of 201 consecutive patients with presumed benign palpable masses who underwent removal with US-VACB. The main outcome measured was the successful removal of palpable masses. Palpable masses were successfully removed with US-VACB in 99% of cases; 2% were cancer and 7.5% were atypical ductal hyperplasia or phyllodes tumor. Two clinical recurrences representing a seroma were seen on follow-up. US-VACB is safe and effective in the initial diagnosis and management of presumed benign palpable breast masses. It provides the benefits of percutaneous biopsy and the palpable abnormality no longer remains.
Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave ... more Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave energy is promising because it can preferentially heat high-water-content breast carcinomas, compared to adipose and glandular tissues. Methods: This is a prospective, multicenter, nonrandomized dose-escalation study of microwave treatment. Thermal dose was measured as (1) thermal equivalent minutes (cumulative equivalent minutes; CEM) of treatment relative to a temperature of 43°C and (2) peak tumor temperature. Microwaves were guided by an antenna-temperature sensor placed percutaneously into the tumor. Outcomes measured were pathologic response (tumor necrosis) side effects. Results: Twenty-five patients (mean age, 57 years) were enrolled. The mean tumor diameter was 1.8 cm. Tumoricidal temperatures (>43°C) were reached in 23 patients (92%). Tumor size was unchanged after thermotherapy (P = not significant). Pathologic necrosis was achieved in 17 (68%) patients. Complete necrosis of the invasive component was achieved in two patients. One hundred forty CEM is predictive of a 50% tumor response, and 210 CEM is predictive of a 100% tumor response (P = .003). Univariate linear regression predicts that peak tumor temperatures of 47.4°C and 49.7°C cause a 50% tumor response and a 100% tumor response, respectively. Conclusions: Thermotherapy causes tumor necrosis and can be performed safely with minimal morbidity. The degree of tumor necrosis is a function of the thermal dose. Future studies will evaluate the impact of high doses of thermotherapy on margin status and complete tumor ablation.
Positive margins after breast conservation surgery occur frequently and negatively influence loca... more Positive margins after breast conservation surgery occur frequently and negatively influence local control rates. Preoperative breast ultrasonography reduces the incidence of positive margins during breast conservation surgery. Case-control analysis. One hundred twenty-two consecutive patients with invasive breast cancer were studied. Palpation or needle-wire-guided breast conservation surgery was used in the first 61 patients (group 1). Preoperative breast ultrasonography was added to the protocol in the last 61 patients (group 2). Incidence of positive margins, distance to closest margin. There was a 3.7-fold reduction in positive margins (P =.04, 95% confidence interval, 1.06-16.73) and improved resection margins (P =.04, 95% confidence interval, 0.14-3.88) when breast ultrasonography was used. Reexcision of margins was done in 11% (7 of 61 patients) in group 1 and 3% (2 of 61 patients) in group 2 (P =.17). Preoperative breast ultrasonography improves the margins of resection and decreases the incidence of positive margins during breast conservation surgery.
Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to d... more Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to determine whether ultrasound-guided vacuum-assisted core biopsy (US-VACB) is safe and effective in completely removing presumed benign palpable breast masses. We conducted a cohort study of 201 consecutive patients with presumed benign palpable masses who underwent removal with US-VACB. The main outcome measured was the successful removal of palpable masses. Palpable masses were successfully removed with US-VACB in 99% of cases; 2% were cancer and 7.5% were atypical ductal hyperplasia or phyllodes tumor. Two clinical recurrences representing a seroma were seen on follow-up. US-VACB is safe and effective in the initial diagnosis and management of presumed benign palpable breast masses. It provides the benefits of percutaneous biopsy and the palpable abnormality no longer remains.
Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave ... more Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave energy is promising because it can preferentially heat high-water-content breast carcinomas, compared to adipose and glandular tissues. Methods: This is a prospective, multicenter, nonrandomized dose-escalation study of microwave treatment. Thermal dose was measured as (1) thermal equivalent minutes (cumulative equivalent minutes; CEM) of treatment relative to a temperature of 43°C and (2) peak tumor temperature. Microwaves were guided by an antenna-temperature sensor placed percutaneously into the tumor. Outcomes measured were pathologic response (tumor necrosis) side effects. Results: Twenty-five patients (mean age, 57 years) were enrolled. The mean tumor diameter was 1.8 cm. Tumoricidal temperatures (>43°C) were reached in 23 patients (92%). Tumor size was unchanged after thermotherapy (P = not significant). Pathologic necrosis was achieved in 17 (68%) patients. Complete necrosis of the invasive component was achieved in two patients. One hundred forty CEM is predictive of a 50% tumor response, and 210 CEM is predictive of a 100% tumor response (P = .003). Univariate linear regression predicts that peak tumor temperatures of 47.4°C and 49.7°C cause a 50% tumor response and a 100% tumor response, respectively. Conclusions: Thermotherapy causes tumor necrosis and can be performed safely with minimal morbidity. The degree of tumor necrosis is a function of the thermal dose. Future studies will evaluate the impact of high doses of thermotherapy on margin status and complete tumor ablation.
Breast cancer tumor ablation as part of a multimodality approach in the treatment of breast cance... more Breast cancer tumor ablation as part of a multimodality approach in the treatment of breast cancer is the subject of recent interest. This study was conducted to determine if the ability to perform sentinel node biopsy was impaired after thermal-induced ablation of breast cancer.We studied patients who had sentinel node biopsy after preoperative focused microwave phased array for breast cancer ablation.Twenty-one patients with T1-T2 breast cancer and clinically negative axilla underwent wide local excision and sentinel node biopsy guided by blue dye and sulfur colloid. Surgery was done an average of 17 days after microwave ablation. Fifteen of 22 patients (68%) had histologic evidence of tumor necrosis. Sentinel lymph node mapping was successful in 19 of 21 patients (91%). Axillary metastases were detected in 42% of cases.This study documents successful sentinel lymph node mapping for patients treated with antecedent local tumor ablation using focused microwave phased array ablation.
Positive margins after breast conservation surgery occur frequently and negatively influence loca... more Positive margins after breast conservation surgery occur frequently and negatively influence local control rates. Preoperative breast ultrasonography reduces the incidence of positive margins during breast conservation surgery. Case-control analysis. One hundred twenty-two consecutive patients with invasive breast cancer were studied. Palpation or needle-wire-guided breast conservation surgery was used in the first 61 patients (group 1). Preoperative breast ultrasonography was added to the protocol in the last 61 patients (group 2). Incidence of positive margins, distance to closest margin. There was a 3.7-fold reduction in positive margins (P =.04, 95% confidence interval, 1.06-16.73) and improved resection margins (P =.04, 95% confidence interval, 0.14-3.88) when breast ultrasonography was used. Reexcision of margins was done in 11% (7 of 61 patients) in group 1 and 3% (2 of 61 patients) in group 2 (P =.17). Preoperative breast ultrasonography improves the margins of resection and decreases the incidence of positive margins during breast conservation surgery.
Ultrasound is commonly used during diagnosis of breast lesions. Our purpose was to study the role... more Ultrasound is commonly used during diagnosis of breast lesions. Our purpose was to study the role of sonography for risk stratification of malignancy in the diagnosis and management of palpable breast cysts.This was a cohort study of 176 patients with palpable breast cysts. Sonographic findings were correlated with clinical and pathologic outcomes.Mean cyst size was 2.0 ± 1.8 cm. Cysts were simple, complex and probably benign, and complex and suspicious for neoplasm in 82.25%, 10.25% and 7.5% of patients, respectively. Thick cyst wall (P = 0.0001), mural tumor (P <0.00001), eccentric mass (P = 0.034), and internal septae (P = 0.031) were predictive of neoplasm. Of cysts >3 cm, 33% were cancerous (P = 0.000027). After 378 days of follow-up, 26 % of cysts had recurred. Recurrence was more frequent in patients with bilateral or multiple cysts (P = 0.004).Sonography is useful in risk stratification of malignancy in breast cysts. There is a high risk of recurrence after cyst aspiration.
Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to d... more Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to determine whether ultrasound-guided vacuum-assisted core biopsy (US-VACB) is safe and effective in completely removing presumed benign palpable breast masses. We conducted a cohort study of 201 consecutive patients with presumed benign palpable masses who underwent removal with US-VACB. The main outcome measured was the successful removal of palpable masses. Palpable masses were successfully removed with US-VACB in 99% of cases; 2% were cancer and 7.5% were atypical ductal hyperplasia or phyllodes tumor. Two clinical recurrences representing a seroma were seen on follow-up. US-VACB is safe and effective in the initial diagnosis and management of presumed benign palpable breast masses. It provides the benefits of percutaneous biopsy and the palpable abnormality no longer remains.
Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave ... more Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave energy is promising because it can preferentially heat high-water-content breast carcinomas, compared to adipose and glandular tissues. Methods: This is a prospective, multicenter, nonrandomized dose-escalation study of microwave treatment. Thermal dose was measured as (1) thermal equivalent minutes (cumulative equivalent minutes; CEM) of treatment relative to a temperature of 43°C and (2) peak tumor temperature. Microwaves were guided by an antenna-temperature sensor placed percutaneously into the tumor. Outcomes measured were pathologic response (tumor necrosis) side effects. Results: Twenty-five patients (mean age, 57 years) were enrolled. The mean tumor diameter was 1.8 cm. Tumoricidal temperatures (>43°C) were reached in 23 patients (92%). Tumor size was unchanged after thermotherapy (P = not significant). Pathologic necrosis was achieved in 17 (68%) patients. Complete necrosis of the invasive component was achieved in two patients. One hundred forty CEM is predictive of a 50% tumor response, and 210 CEM is predictive of a 100% tumor response (P = .003). Univariate linear regression predicts that peak tumor temperatures of 47.4°C and 49.7°C cause a 50% tumor response and a 100% tumor response, respectively. Conclusions: Thermotherapy causes tumor necrosis and can be performed safely with minimal morbidity. The degree of tumor necrosis is a function of the thermal dose. Future studies will evaluate the impact of high doses of thermotherapy on margin status and complete tumor ablation.
Positive margins after breast conservation surgery occur frequently and negatively influence loca... more Positive margins after breast conservation surgery occur frequently and negatively influence local control rates. Preoperative breast ultrasonography reduces the incidence of positive margins during breast conservation surgery. Case-control analysis. One hundred twenty-two consecutive patients with invasive breast cancer were studied. Palpation or needle-wire-guided breast conservation surgery was used in the first 61 patients (group 1). Preoperative breast ultrasonography was added to the protocol in the last 61 patients (group 2). Incidence of positive margins, distance to closest margin. There was a 3.7-fold reduction in positive margins (P =.04, 95% confidence interval, 1.06-16.73) and improved resection margins (P =.04, 95% confidence interval, 0.14-3.88) when breast ultrasonography was used. Reexcision of margins was done in 11% (7 of 61 patients) in group 1 and 3% (2 of 61 patients) in group 2 (P =.17). Preoperative breast ultrasonography improves the margins of resection and decreases the incidence of positive margins during breast conservation surgery.
Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to d... more Abstract: A palpable breast mass is a common reason for surgical consultation. Our goal was to determine whether ultrasound-guided vacuum-assisted core biopsy (US-VACB) is safe and effective in completely removing presumed benign palpable breast masses. We conducted a cohort study of 201 consecutive patients with presumed benign palpable masses who underwent removal with US-VACB. The main outcome measured was the successful removal of palpable masses. Palpable masses were successfully removed with US-VACB in 99% of cases; 2% were cancer and 7.5% were atypical ductal hyperplasia or phyllodes tumor. Two clinical recurrences representing a seroma were seen on follow-up. US-VACB is safe and effective in the initial diagnosis and management of presumed benign palpable breast masses. It provides the benefits of percutaneous biopsy and the palpable abnormality no longer remains.
Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave ... more Background: Tumor ablation as a means of treating breast cancer is being investigated. Microwave energy is promising because it can preferentially heat high-water-content breast carcinomas, compared to adipose and glandular tissues. Methods: This is a prospective, multicenter, nonrandomized dose-escalation study of microwave treatment. Thermal dose was measured as (1) thermal equivalent minutes (cumulative equivalent minutes; CEM) of treatment relative to a temperature of 43°C and (2) peak tumor temperature. Microwaves were guided by an antenna-temperature sensor placed percutaneously into the tumor. Outcomes measured were pathologic response (tumor necrosis) side effects. Results: Twenty-five patients (mean age, 57 years) were enrolled. The mean tumor diameter was 1.8 cm. Tumoricidal temperatures (>43°C) were reached in 23 patients (92%). Tumor size was unchanged after thermotherapy (P = not significant). Pathologic necrosis was achieved in 17 (68%) patients. Complete necrosis of the invasive component was achieved in two patients. One hundred forty CEM is predictive of a 50% tumor response, and 210 CEM is predictive of a 100% tumor response (P = .003). Univariate linear regression predicts that peak tumor temperatures of 47.4°C and 49.7°C cause a 50% tumor response and a 100% tumor response, respectively. Conclusions: Thermotherapy causes tumor necrosis and can be performed safely with minimal morbidity. The degree of tumor necrosis is a function of the thermal dose. Future studies will evaluate the impact of high doses of thermotherapy on margin status and complete tumor ablation.
Breast cancer tumor ablation as part of a multimodality approach in the treatment of breast cance... more Breast cancer tumor ablation as part of a multimodality approach in the treatment of breast cancer is the subject of recent interest. This study was conducted to determine if the ability to perform sentinel node biopsy was impaired after thermal-induced ablation of breast cancer.We studied patients who had sentinel node biopsy after preoperative focused microwave phased array for breast cancer ablation.Twenty-one patients with T1-T2 breast cancer and clinically negative axilla underwent wide local excision and sentinel node biopsy guided by blue dye and sulfur colloid. Surgery was done an average of 17 days after microwave ablation. Fifteen of 22 patients (68%) had histologic evidence of tumor necrosis. Sentinel lymph node mapping was successful in 19 of 21 patients (91%). Axillary metastases were detected in 42% of cases.This study documents successful sentinel lymph node mapping for patients treated with antecedent local tumor ablation using focused microwave phased array ablation.
Uploads