Spray freeze-drying has emerged as a valid alternative to traditional spray drying to produce therapeutic dry microparticles. In particular, the spherical shape and high porosity of spray freeze-dried microparticles make them suitable for pulmonary drug delivery through dry powder inhalers. However, an appropriate particle size and fine particle fraction are required to guarantee lung deposition. This study used ultrasonic spray freeze-drying to generate dry microparticles composed of mannitol either alone or added with the bronchodilator salbutamol sulphate. The influence of the solid concentration and the feed flow rate on the particle size, morphology, surface area, porosity, and crystallinity was investigated. Growing particle size was observed, increasing the concentration and feed flow rate. Similarly, the addition of the drug led to a larger particle size and surface area. The in vitro simulation of drug deposition highlighted the dependence of the aerodynamic properties on the solid concentration and feed flow rate. Due to the lower density and particle geometric size, the highest fine particle fraction (26%) and smallest mass median aerodynamic diameter (4.4 μm) were reached at the lowest solid concentration and feed flow rate.
Tailoring dry microparticles for pulmonary drug delivery: ultrasonic spray freeze-drying with mannitol and salbutamol sulphate / Pasero, Lorena; Susa, Francesca; Chiavarino, Riccardo; Limongi, Tania; Sulpizi, Adamo; Guidi, Tomaso; Pisano, Roberto. - In: PROCESSES. - ISSN 2227-9717. - STAMPA. - 11:11(2023). [10.3390/pr11113096]
Tailoring dry microparticles for pulmonary drug delivery: ultrasonic spray freeze-drying with mannitol and salbutamol sulphate
Lorena Pasero;Francesca Susa;Tania Limongi;Roberto Pisano
2023
Abstract
Spray freeze-drying has emerged as a valid alternative to traditional spray drying to produce therapeutic dry microparticles. In particular, the spherical shape and high porosity of spray freeze-dried microparticles make them suitable for pulmonary drug delivery through dry powder inhalers. However, an appropriate particle size and fine particle fraction are required to guarantee lung deposition. This study used ultrasonic spray freeze-drying to generate dry microparticles composed of mannitol either alone or added with the bronchodilator salbutamol sulphate. The influence of the solid concentration and the feed flow rate on the particle size, morphology, surface area, porosity, and crystallinity was investigated. Growing particle size was observed, increasing the concentration and feed flow rate. Similarly, the addition of the drug led to a larger particle size and surface area. The in vitro simulation of drug deposition highlighted the dependence of the aerodynamic properties on the solid concentration and feed flow rate. Due to the lower density and particle geometric size, the highest fine particle fraction (26%) and smallest mass median aerodynamic diameter (4.4 μm) were reached at the lowest solid concentration and feed flow rate.File | Dimensione | Formato | |
---|---|---|---|
a-2023_PROCESSES-11-03096.pdf
accesso aperto
Descrizione: a-2023_PROCESSES-11-03096
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Creative commons
Dimensione
4.66 MB
Formato
Adobe PDF
|
4.66 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2985176