Abstract
This chapter provides an introduction to the basic principles of computed tomography. It discusses the relevant hardware and software components of a CBCT system and its impact on image quality. It reviews radiation dose considerations when using this x-ray-based imaging modality, and provides data to help communicate radiation risks to the patient. It discusses methods to minimize patient radiation exposure and guides the reader to select an appropriate protocol for CBCT imaging.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Pauwels R, Beinsberger J, Stamatakis H, Tsiklakis K, Walker A, Bosmans H, Bogaerts R, Jacobs R, Horner K, Consortium SP. Comparison of spatial and contrast resolution for cone-beam computed tomography scanners. Oral Surg Oral Med Oral Pathol Oral Radiol. 2012;114(1):127–35. doi:10.1016/j.oooo.2012.01.020.
Seibert JA. Flat-panel detectors: how much better are they? Pediatr Radiol. 2006;36 Suppl 14:173–81.
Wang J, Blackburn TJ. The AAPM/RSNA physics tutorial for residents: X-ray image intensifiers for fluoroscopy. Radiographics. 2000;20(5):1471–7.
Bechara B, McMahan CA, Moore WS, Noujeim M, Geha H, Teixeira FB. Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines. J Oral Sci. 2012;54(3):227–32.
Neves FS, Vasconcelos TV, Campos PS, Haiter-Neto F, Freitas DQ. Influence of scan mode (180 degrees/360 degrees) of the cone beam computed tomography for preoperative dental implant measurements. Clin Oral Implants Res. 2014;25(2):e155–8. doi:10.1111/clr.12080.
Hassan BA, Payam J, Juyanda B, van der Stelt P, Wesselink PR. Influence of scan setting selections on root canal visibility with cone beam CT. Dentomaxillofac Radiol. 2012;41(8):645–8. doi:10.1259/dmfr/27670911.
Schulze R, Heil U, Groβ D, Bruellmann DD, Dranischnikow E, Schwanecke U, Schoemer E. Artefacts in CBCT: a review. Dentomaxillofac Radiol. 2011;40(5):265–73. doi:10.1259/dmfr/30642039.
The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37(2–4):1–332. doi:10.1016/j.icrp.2007.10.003 S0146-6453(07)00031-0 [pii].
Cody DD, Brateman LF, Favinger J, Geise RA, Kritzman ML, Rosen MP, Rybicki FJ, Schueler BA, Strauss KJ. ACR Appropriateness Criteria® Radiation Dose Assessment Introduction. 2015. http://www.acr.org/~/media/a27a29133302408bb86888eafd460a1f.pdf. Accessed 2 Aug 2015.
AAE and AAOMR Joint Position Statement: Use of Cone Beam Computed Tomography in Endodontics 2015 Update. (2015). http://www.aae.org/uploadedfiles/clinical_resources/guidelines_and_position_statements/cbctstatement_2015update.pdf. Accessed 2 Aug 2015.
Ludlow JB, Timothy R, Walker C, Hunter R, Benavides E, Samuelson DB, Scheske MJ. Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol. 2015;44(1):20140197. doi:10.1259/dmfr.20140197.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Mallya, S.M. (2016). Principles of Cone Beam Computed Tomography. In: Fayad, M., Johnson, B. (eds) 3D Imaging in Endodontics. Springer, Cham. https://doi.org/10.1007/978-3-319-31466-2_1
Download citation
DOI: https://doi.org/10.1007/978-3-319-31466-2_1
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-31464-8
Online ISBN: 978-3-319-31466-2
eBook Packages: MedicineMedicine (R0)