Abstract
Owing to the successful use of non-invasive vibration analysis to monitor the progression of dental implant healing and stabilization, it is now being considered as a method to monitor femoral implants in transfemoral amputees. This study uses composite femur–implant physical models to investigate the ability of modal analysis to detect changes at the interface between the implant and bone simulating those that occur during osseointegration. Using electromagnetic shaker excitation, differences were detected in the resonant frequencies and mode shapes of the model when the implant fit in the bone was altered to simulate the two interface cases considered: firm and loose fixation. The study showed that it is beneficial to examine higher resonant frequencies and their mode shapes (rather than the fundamental frequency only) when assessing fixation. The influence of the model boundary conditions on the modal parameters was also demonstrated. Further work is required to more accurately model the mechanical changes occurring at the bone–implant interface in vivo, as well as further refinement of the model boundary conditions to appropriately represent the in vivo conditions. Nevertheless, the ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation.
Similar content being viewed by others
References
Aschoff HH, Clausen A, Hoffmeister T (2009) The endo–exo femur prosthesis—a new concept of bone-guided, prosthetic rehabilitation following above-knee amputation. Z Orthop Unfall 147(5):610–615
Avitabile P (1999) Modal space: back to basics. Exp Tech 23(3):17–18
Avitabile P (1999) Modal space: back to basics. Exp Tech 23(5):17–18
Avitabile P (2000) Modal space: back to basics. Exp Tech 24(3):13–14
Avitabile P (2005) Modal space: back to basics. Exp Tech 29(6):23–24
Blevins RD (1979) Straight beams. In: Yalof B (ed) Formulas for natural frequency and mode shape. Van Nostrand Reinhold Company, New York, pp 101–200
Blunn GW, Pendegrass CJ 2011 Development of an intraosseous transcutaneous amputation prostheses (Itap). In: 2011 Myoelectric controls/powered prosthetics symposium, Fredericton, New Brunswick, Canada
Cairns NJ 2010 The feasibility of vibration analysis as a technique to detect osseointegration of transfemoral implants. PhD Thesis, Queensland University of Technology, Brisbane, Australia
Cairns NJ, Adam CJ, Pearcy MJ, Smeathers J 2011 Evaluation of modal analysis techniques using physical models to detect osseointegration of implants in transfemoral amputees. In: Patton J (ed) Engineering in medicine and biology society (EMBC), 2011 annual international conference of the IEEE, Boston, USA, pp 1600–1603
Delgado D, Jones R, Fuentes AA, Lumsdaine A 2002 Quantitative determination of the stability of implant–bone interface using resonance frequency analysis. In: ASME international mechanical engineering congress and exposition, New Orleans, pp 103–111
Dias Rodrigues JF, Lopes H, de Melo FQ, Simoes JA (2004) Experimental modal analysis of a synthetic composite femur. Exp Mech 44:29–32
Dossing O 1988 Part 2 modal analysis and simulation. In: Bruel&Kjaer (ed) Structural testing. Bruel&Kjaer, Naerum, pp 1–56
Elias JJ, Brunski JB, Scarton HA (1996) A dynamic modal testing technique for noninvasive assessment of bone–dental implant interfaces. J Oral Maxillofac Implants 11:728–734
Hagberg K (2005) Physiotherapy for patients having a trans-femoral amputation. In: Chien S, Grondahl HG, Robinson K (eds) The osseointegration book from calvarium to calcaneus. Quintessenz Verlags-GmbH, Berlin, pp 477–487
Hagberg K, Brånemark R (2009) One hundred patients treated with osseointegrated transfemoral amputation prostheses—rehabilitation perspective. J Rehab Res Dev 46:331–344
Hagberg K, Brånemark R, Gunterberg B, Rydevik B (2008) Osseointegrated trans-femoral amputation prostheses: prospective results of general and condition-specific quality of life in 18 patients at 2-year follow up. Prosthet Orthot Int 32:29–41
He J, Fu ZF (2001) Frequency response function measurement. In: He J, Fu ZF (eds) Modal analysis. Butterworth Heinemann, Oxford, pp 140–158
Huang HM, Cheng KY, Chen CF, Ou KL, Lin CT, Lee SY (2005) Design of a stability-detecting device for dental implants. Proc Inst Mech Eng H 219:203–211
Khalil TB, Viano DC, Taber LA (1981) Vibrational characteristics of the embalmed human femur. J Sound Vib 75(3):417–436
Lachmann S, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H (2006) Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 17:75–79
Lachmann S, Laval JY, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H (2006) Resonance frequency analysis and damping capacity assessment. Part 2: peri-implant bone loss follow-up. An in vitro study with the periotest and osstell instruments. Clin Oral Implants Res 17:80–84
Maia NMM, Silva JMM, He J, Lieven NAJ, Lin RM, Skingle GW, To W-M, Urgueira APV (1997) Modal testing. In: Maia NMM, Silva JMM (eds) Theoretical and experimental modal analysis. SRP Ltd, pp 123-184
Mayes RL, Gomez AJ (2006) Part 4: what’s shakin’, dude? Effective use of modal shakers. Exp Tech 30:51–61
Meredith N, Alleyne D, Cawley P (1996) Quantitative determination of the stability of the implant–tissue interface using resonance frequency analysis. Clin Oral Implants Res 7:261–267
Meredith N, Boo K, Friberg B, Jemt T, Sennerby L (1997) Resonance frequency measurement of implant stability in vivo. Clin Oral Implants Res 8:226–233
Nikiforidis G, Bezerianos A, Dimarogonas A, Sutherland C (1990) Monitoring of fracture healing by lateral and axial vibration analysis. J Biomech 23:323–330
Schuch CM, Pritham CH (2004) Transfemoral amputation: prosthetic management. In: Smith DG, Michael JW, Bowker JH (eds) Atlas of amputations and limb deficiencies surgical prosthetic and rehabilitation principles. American Academy of Orthopaedic Surgeons, Rosemont, pp 541–555
Shao F, Xu W, Crocombe A, Ewins D (2007) Natural frequency analysis of osseointegration for trans-femoral implant. Ann Biomed Eng 35:817–824
Shelton TJ, Beck JP, Bloebaum RD, Bachus KN (2011) Percutaneous osseointegrated prostheses for amputees: limb compensation in a 12-month ovine model. J Biomech 44:2601–2606
Sullivan J, Uden M, Robinson KP, Sooriakumaran S (2003) Rehabilitation of the trans-femoral amputee with an osseointegrated prosthesis: the United Kingdom experience. Prosthet Orthot Int 27:114–120
Ward DA, Robinson KP (2005) Osseointegration for the skeletal fixation of limb prostheses in amputations at the trans-femoral level. In: Chien S, Grondahl HG, Robinson K (eds) The osseointegration book from calvarium to calcaneus. Quintessenz Verlags-GmbH, Berlin, pp 463–476
Xu W, Shao F, Ewins D (2005) A resonant frequency measurement system for osseointegration trans-femoral implant. Key Eng Mater 295:139–144
Acknowledgments
This work was funded by an Australian Government International Postgraduate Research Scholarship. The authors would like to thank the Built Environment and Engineering workshop staff at Queensland University of Technology for their technical assistance in the preparation of the physical models.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cairns, N.J., Pearcy, M.J., Smeathers, J. et al. Ability of modal analysis to detect osseointegration of implants in transfemoral amputees: a physical model study. Med Biol Eng Comput 51, 39–47 (2013). https://doi.org/10.1007/s11517-012-0962-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-012-0962-0