RAZÃO
Sintético 62.00%
Água 38.00% Balanço de Massa HZupo®

Volfinal 3100 bbl MW 9.5 lb/gal

Água corrigida 100.00% Salmoura Cloreto de Sódio

Salinidade da Salmoura utilizada 273889 mg/l Conc 13.67 lb/bbl


Salinidade Desejada 39001 mg/l Salmoura 121 bbl
Salinidade da Água de diluição 0 mg/l Água ind. 731 bbl

Produto SG Concentração (lb/bbl) Volume (bbl) Massa (lb) Massa (kg) kg/U NOUnid
SALMOURA 1.08 103.47 851.91 320760.42 145494.48 200 727.47
F.Continua
0.00 0.00 1389.96 0.00 0.00 0.00

1 DRIL-KLEEN 1.10 0.35 2.82 1085.00 492.15 20.00 24.61


2 DUO-VIS 1.50 1.20 7.09 3720.00 1687.36 25.00 67.49
3 MI-TROL 1.50 6.00 35.43 18600.00 8436.82 25.00 337.47
4 MI-CIDE 1.16 0.50 3.83 1550.00 703.07 20.00 35.15
5 KCl TIPO II 1.98 15.00 67.10 46500.00 21092.05 50.00 421.84
6 POLYSAFE 600 1.60 1.00 5.54 3100.00 1406.14 25.00 56.25
7 POLYSAFE ADS Tipo 2 1.60 2.00 11.07 6200.00 2812.27 25.00 112.49
8 KLA-GARD 1.10 6.00 48.31 18600.00 8436.82 228.80 36.87
9 CARBONATO Ca 2-44 2.80 25.00 79.08 77500.00 35153.41 30.00 1171.78
10 0.00 0.00 0.00 0.00
11 0.00 0.00 0.00 0.00
12 0.00 0.00 0.00 0.00
13 0.00 0.00 0.00 0.00
14 0.00 0.00 0.00 0.00

Adensante BARITA 4.20 283.50 597.86 878848.74 398639.08 50.00 7972.78


Completion Fluids
Vol de Fluído
input 450 bbl

CADIT 9.2 ppg 20% VOL CADIT 90 bbl

FILTRAÇÃO

Diluir com ÁGUA DO MAR até peso 9.1 ppg 80% VOL Água Mar 360 bbl

Adicionar

Mais aditivos Sequestrante de O2 Polisol 40 B 0.07 l/bbl 31.5 litros

Bactericida Polibac TC 0.07 l/bbl 31.5 litros

Preventor de emulsão Ultrawet 70 0.32 l/bbl 144.0 litros

pH NaOH 0.1 kg/bbl 45.0 kg

CAMAI 9.1 ppg O PESO ESPECIFICADO PELO PROGRAMA

Mais aditivos Anticorrosivo TetraHib 0.38 l/bbl 171.0 litros

CASAM 9.1 ppg Packer Fluids

H.Zupo
Adensamento com fluídos de ρ diferentes HZupo®

FLUÍDO 1 FLUÍDO 2 Fluído Resultante


1 Caso:
O ρ 1
lb/gal
V1 bbl
9.9
220
+ ρ2 lb/gal
V2 bbl
9.4
380
= ρR lb/gal
VR bbl
9.58
600

FLUÍDO 1 FLUÍDO 2 Fluído Desejado


2 Caso: ρ1 lb/gal
O

V1 bbl
9.4
360.0
+ ρ2 lb/gal
V2 bbl
9.9
240.0
= ρD lb/gal
VD bbl
9.6
600
Adensando com Barita/CaCO3
HZupo®

DESEJO ADENSAR UM VOLUME INICIAL


1 Caso:
O VOLUME bbl ρ lb/gal QDE DE: Calcário
kg 30kg/SC
Inicial 327.00 9.6

1066 35.54
Final 329.40 9.7

DESEJO OBTER UM VOLUME FINAL


2OCaso: VOLUME bbl ρ lb/gal QDE DE: Barita
kg 50kg/SC
Inicial 1818.25 9.5

14433 288.66
Final 1839.90 9.8
M-I Drilling Fluids do Brasil Ltda Sonda: P-16
Poço: 7-PM-49DB-RJS Data: 10/5/2006
Eng. Químico: Alan P. de Oliveira Rangel

Autor:

Henrique Zupo Augusto

Eng. Químico:

Profundidade TMD

Poço 0 m ROP m/h WASHOUT Cp gal/m

Broca 2564 m 607.22 15.00 2.52 10.09

Revestimento
Casing Comp m TMD m Comp m ID in TVD m ECD ppg VABB bbl

Riser 0 240 240 17.375


### 1447.5 #VALUE! 0.0
C
a Casing 0 1426 1186 9.660
### 2194.5 #VALUE! 0.0
s
i Open Hole 0 2564 1138 8.681
### 2475.0 #VALUE! 0.0
n
g Open Hole 0 0 -2564 8.535
### 2505.0 #VALUE! 0.0

Open Hole -2564 0 0 8.500


### 2520.0 #VALUE! -590.4

Volumetria
Vol bbl Stk's Tempo min Vol bbl

Circulação 194 3321 33 Atual 900


S
i Poço -194 3321 33 Tanque Ativo 0
s
t Anular 256 2139
### 18 Volume Morto 0
e
m Coluna 141 1182 15 Tq Manobra 0
a
Choke/Kill/Booster 14 115
### 2 Reserva 0

Desenho da Coluna
Coluna Comp m ID in OD in V aço bbl

DP 2272.03 4.276 5.000 48.6

HWDP 291.97 198.93 3.000 5.000 10.1

DC 93.04 55.20 2.810 6.750 6.6


B 37.84 9.44 2.750 6.750 1.1
NMDC

MWD.PP 6,75" 28.40 8.90 3.380 6.880 1.0


H
LWD.ARC 6,75" 19.50 5.87 3.130 6.880 0.7

NMDC 13.63 3.04 2.750 6.750 0.4


A
Stab 10.59 1.81 2.750 6.750 0.2

Float sub 8.78 0.79 4.870 6.500 0.0

MudM 7.99 5.500 6.750 0.4

Somatória 2564.00 69.3

Tempos
ID in Vol bbl Vazão gpm Tempo min Stk's Bombas

Kill 3 6.9 250 1.16 58 (3)

T Choke 3 6.9 250 1.16 58 (3)


e
m Booster 0 0.0 250 0.00 0 (3)
p
o Coluna 141.2 400 14.82 1182 (1)
s Riser
211.8 650 13.69 1773 (1)(3)
Anular
43.7 400 4.59 366 (1)
Abaixo Riser

Bombas Triplex
Bombas Vazão gpm Liner in ID in Eficiência bbl/Stk Stk's/min Estatos
B
o
m 1 400 12 6.5 97.00% 0.1194 80 Coluna ###
b
a 2 12 6.5 97.00% 0.1194 0 ###
s
3 250 12 6.5 97.00% 0.1194 50 Riser ###

###

HZupo

Henrique Zupo Augusto Página 6 08/30/2021


Volume de fluído no interior da coluna
POÇO Comp m Riser Casing Open Hole Open Hole Open Hole V fluído bbl
m
DP 2272.03 240.00 1186.00 846.03 -2564.00 0.00 132.4

HWDP 198.93 0.00 0.00 198.93 0.00 0.00 5.7

B DC 55.20 0.00 0.00 55.20 0.00 0.00 1.4

NMDC 9.44 0.00 0.00 9.44 0.00 0.00 0.2

H MWD.PP 6,75" 8.90 0.00 0.00 8.90 0.00 0.00 0.3

LWD.ARC 6,75" 5.87 0.00 0.00 5.87 0.00 0.00 0.2

A NMDC 3.04 0.00 0.00 3.04 0.00 0.00 0.1

Stab 1.81 0.00 0.00 1.81 0.00 0.00 0.0

Float sub 0.79 0.00 0.00 0.79 0.00 0.00 0.1

MudM 7.99 0.00 0.00 7.99 0.00 0.00 0.8

Somatória 2564.00 240 1186 1138 -2564.00 0.00 141.2

Volume de fluído no anular


POÇO Comp m Riser Casing Open Hole Open Hole Open Hole V fluído bbl
bbl
DP 2272.03 211.79 258.23 135.79 -390.99 0.00 214.8
A
HWDP 198.93 0.00 0.00 31.93 0.00 0.00 31.9
n DC 55.20 0.00 0.00 5.24 0.00 0.00 5.2

NMDC 9.44 0.00 0.00 0.90 0.00 0.00 0.9


u
MWD.PP 6,75" 8.90 0.00 0.00 0.79 0.00 0.00 0.8
l LWD.ARC 6,75" 5.87 0.00 0.00 0.52 0.00 0.00 0.5

NMDC 3.04 0.00 0.00 0.29 0.00 0.00 0.3


a
Stab 1.81 0.00 0.00 0.17 0.00 0.00 0.2
r Float sub 0.79 0.00 0.00 0.08 0.00 0.00 0.1

MudM 7.99 0.00 0.00 0.76 0.00 0.00 0.8

Somatória 2564.00 211.79 258.23 176.48 -390.99 0.00 255.5

Eficiência da Bomba de Perfuração %


P bombeio 3900 psi Vazão Real de Circulação

Ef. bomba #VALUE! Vazão #VALUE! gpm


Diâmetro da Particula (in)
Diâmetro do Cascalho 0.2 in
Máximo Dpart Suspensa Estática 0.071 in
Tempo de Retorno (min)
Tempo de Retorno do Fluído (min) #VALUE! min
Tempo de Retorno do Cascalho (min) #VALUE! min
Propriedades do Fluido
Peso lb/gal Leituras 55°F 85°F 120°F

Fluido 9.50 θ 600 75 59 95

Sólidos 21.70 θ 300 55 43 63

Anular 9.55 θ3 9 7 16

Gráficos
Perda de Carga ECD
Coluna ### ###
0
Broca ### 1447.5
###
10.00
Anular ### 2194.5
###
ppg
2475.0
###
2505.0
9.00 ###
2520
###

8.00
0% 25% 50% 75% 100% TVD m
0 1000 2000 3000

HZupo

Henrique Zupo Augusto Página 7 08/30/2021


Hidráulica " Potência Modificada Bull API 13D "
Índice de Comportmento (n) & Consistência (k) (dina.sn/cm2)
n k a b
í
n Coluna 0.447199 17.250719 0.071610 0.299928
d
Anular 0.393060 24.174678 0.070489 0.307934

Velocidade de escoamento: Coluna & Anular


Coluna Riser Casing Open Hole Open Hole Open Hole
V m/min 1 m/min 0.05

e DP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

l HWDP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

o DC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

c NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

i MWD.PP 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

d LWD.ARC 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

a NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


d Stab #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
e Float sub #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MudM #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Visosidade Equivalente (μe) (cp)


Coluna Riser Casing Open Hole Open Hole Open Hole
cp cp

DP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

HWDP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


μ DC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MWD.PP 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


e
LWD.ARC 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
q
NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Stab #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Float sub #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MudM #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Número de Reynoids (Re) (Adimensional)


Coluna Riser Casing Open Hole Open Hole Open Hole

DP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

HWDP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

DC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


R
MWD.PP 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
e
LWD.ARC 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Stab #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Float sub #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MudM #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Regime de Fluxo
Coluna Riser Casing Open Hole Open Hole Open Hole

DP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

HWDP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

F DC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


l NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
u MWD.PP 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
x LWD.ARC 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
o NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Stab #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Float sub #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MudM #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

HZupo

Henrique Zupo Augusto Página 8 08/30/2021


Fator de Fricção de Fanning (f) (Adimensional)
Coluna Riser Casing Open Hole Open Hole Open Hole

f DP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

F HWDP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

DC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


a
NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
n
MWD.PP 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
n
LWD.ARC 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
i
NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
n
Stab #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
g Float sub #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MudM #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Perda de Carga (psi)


Coluna Riser Casing Open Hole Open Hole Open Hole

DP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

HWDP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

DC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


Δ Δ
p NMDC #VALUE! p #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
i a
MWD.PP 6,75" 95.00 #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

C LWD.ARC 6,75" 12.56 A #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


o n
l NMDC #VALUE! u #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
u l
n Stab #VALUE! a #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
a r
Float sub #VALUE! #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MudM 600.00 #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Somatória #VALUE! Calculada #VALUE!


Motor 600.0 Corrigida #VALUE!

D in Qde
Δ ΔpBroca psi PhB hp FIB lbf
11 4
p
10 2 Calculada 506.82 118.28 480.00
B
r Corrigida #VALUE! #VALUE! #VALUE!
o
c A.T.Fluxo 0.52 in2
a
Vel Jat #VALUE! ft/s

Δp Superfície
T. bengala Mangueira Swivel Kelly
L ( ft ) D ( in ) L ( ft ) D ( in ) L ( ft ) D ( in ) L ( ft ) D ( in )

1 ### 40 3 40 2 4 2 40 2 1/4
2 ### 40 3 1/2 55 2 1/2 5 2 1/2 40 3 1/4
3 ### 45 4 55 3 5 2 1/2 40 3 1/2
4 ### 45 4 55 3 6 3 40 4
5### 13.72 3 1/2 16.76 2 1/2 1.83 2 1/2 12.19 3 1/2

Caso: 3.00 #VALUE! psi

Pressão de Circulação: ΔPc ### psi


Eficiência de Remoção dos Cascalhos (%)
Riser Casing Open Hole Open Hole Open Hole

DP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

HWDP #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!


E
f DC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
i
c NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
i
ê MWD.PP 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
n
c LWD.ARC 6,75" #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!
i
a NMDC #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Stab #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

Float sub #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

MudM #VALUE! #VALUE! #VALUE! #VALUE! #VALUE!

HZupo

Henrique Zupo Augusto Página 9 08/30/2021


REVESTIMENTO POÇO
OD 30 20 13 3/8 13 3/8 9 5/8 9 5/8 7 5/8 7 5/8 7 7
ID 28 18.730 12.515 12.415 8.755 8.681 6.625 6.435 6.276 6.184 26 17 1/2 12 1/4 8 1/2
PESO 310 133 61 68 43.5 47 39 45.3 26 29
CAPACIDAD 2.498608 1.1180 0.4992 0.4912 0.2443 0.2402 0.1399 0.1320 0.1255 0.1219 2.1544 0.9760 0.4782 0.2303
OD ID PESO CAPACIDADE DESLOCAM.
pol. pol. lb/ft BBL/M BBL/M CAPACIDADE DOS ANULARES (BBL/M)
TUBING 2 3/8 2.041 4 0.0133 0.00470 2.8420 1.2485 0.5438 0.5438 0.2689 0.2689 0.1590 0.1590 0.1298 0.1298
TUBING 2 7/8 2.441 6.5 0.0190 0.00735 2.4723 1.0917 0.4728 0.4649 0.2179 0.2138 0.1135 0.1056 0.0992 0.0955 2.1281 0.9497 0.4519 0.2039
TUBING 3 1/2 2.531 9.3 0.0204 0.01862 2.4596 1.0790 0.4601 0.4522 0.2052 0.2011 0.1008 0.0929 0.0865 0.0828 2.1154 0.9370 0.4392 0.1912
TUBING 4 1/2 3.958 12.75 0.0499 0.01461 2.4341 1.0535 0.4346 0.4267 0.1797 0.1756 0.0753 0.0674 0.0610 0.0573 2.0899 0.9115 0.4137 0.1657

TUBO 3 1/2 2.764 13.3 0.0243 0.01469 2.4596 1.0790 0.4601 0.4522 0.2052 0.2011 0.1008 0.0929 0.0865 0.0828 2.1154 0.9370 0.4392 0.1912
TUBO 4 1/2 3.826 16.6 0.0467 0.01788 2.4341 1.0535 0.4346 0.4267 0.1797 0.1756 0.0753 0.0674 0.0610 0.0573 2.0899 0.9115 0.4137 0.1657
TUBO 5 4.276 12.5 0.0583 0.02140 2.4189 1.0384 0.4195 0.4115 0.1646 0.1605 0.0602 0.0523 0.0459 0.0422 2.0747 0.8963 0.3986 0.1506
HEAVY WEIGHT 5 3.000 49.3 0.0287 0.05099 2.4189 1.0384 0.4195 0.4115 0.1646 0.1605 0.0602 0.0523 0.0459 0.0422 2.0747 0.8963 0.3986 0.1506
HEAVY WEIGHT 3 1/2 2 1/16 25.3 0.0136 0.02548 2.4596 1.0790 0.4601 0.4522 0.2052 0.2011 0.1008 0.0929 0.0865 0.0828 2.1154 0.9370 0.4392 0.1912

COMANDO 4 3/4 2 1/4 47 0.0161 0.05577 2.4267 1.0461 0.4273 0.4193 0.1724 0.1683 0.0680 0.0601 0.0536 0.0500 2.0825 0.9041 0.4063 0.1584
COMANDO 6 3/4 2 13/16 100 0.0252 0.12000 2.3534 0.9728 0.3540 0.3460 0.0991 0.0950 2.0092 0.8308 0.3330 0.0851
COMANDO 7 3/4 3 136 0.0287 0.16274 2.3072 0.9266 0.3077 0.2998 0.0529 0.0488 1.9630 0.7846 0.2868 0.0388
COMANDO 8 3 147 0.0287 0.17529 2.2946 0.9141 0.2952 0.2873 0.0403 0.0362 1.9504 0.7721 0.2743 0.0263
COMANDO 9 1/2 3 216 0.0287 0.25894 2.2110 0.8304 0.2115 0.2036 1.8668 0.6884 0.1906

REVESTIM. 30 28.00 310 2.4986 0.36969


REVESTIM. 20 18.73 133 1.1180 0.15676 1.2238
REVESTIM. 13 3/8 12.515 61 0.4992 0.07096 1.9285 0.5479
REVESTIM. 13 3/8 12.415 68 0.4912 0.07891 1.9285 0.5479
REVESTIM. 9 5/8 8.755 43.5 0.2443 0.05096 2.2034 0.8228 0.2039 0.1960 1.8592 0.6808 0.1830
REVESTIM. 9 5/8 8.681 47 0.2402 0.05507 2.2034 0.8228 0.2039 0.1960 1.8592 0.6808 0.1830
REVESTIM. 7 5/8 6.625 39 0.1399 0.04541 2.3133 0.9327 0.3139 0.3059 0.0590 0.0549 1.9691 0.7907 0.2930 0.0450
REVESTIM. 7 5/8 6.435 45.3 0.1320 0.05332 2.3133 0.9327 0.3139 0.3059 0.0590 0.0549 1.9691 0.7907 0.2930 0.0450
REVESTIM. 7 6.276 26 0.1255 0.03063 2.3424 0.9619 0.3430 0.3351 0.0881 0.0840 1.9982 0.8199 0.3221 0.0741
REVESTIM. 7 6.184 29 0.1219 0.03429 2.3424 0.9619 0.3430 0.3351 0.0881 0.0840 1.9982 0.8199 0.3221 0.0741

Grau API = (141,5 / d(@60º F)) - 131,5 C = 5 / 9 x (º F- 32) PH = 0,052 x 3,281 x PL x H 1 bbl = 5,61ft3 = 158,9 L = 42 gal
PH = 0,17 x p x h

REFERÊNCIA ID" Comp.(M) Cap(bbl/m) Vol.(bbl)

RISER
19 3/4" 19.750 0.00 1.2431 0.0
19" 19.000 0.00 1.1505 0.0
19 5/8" 19.625 0.00 1.2274 0.0
17 1/4" 17.250 0.00 0.9483 0.0
17 3/8" 17.375 0.00 0.9621 0.0
Volume total riser. 0.0
Margem de Segurança de Manobra - MSM

Margem de Segurança de Riser - MSR

LE×0 , 17 LDP LDC


MSM =
PROF
× +
(
( DH −DDP ) ( DH −DDC )
( lb/ gal ) )
PROF ×PP−( 8,5×LA )
MSR= −PP  (lb/ gal )
PROF −LA

Peso de Fluido Mínimo - PFM

O Peso de Fluido Mínimo será o maior valor calculado entre as duas equações abaixo:
lb/gal
PFM1 = PP + MSM ( lb/gal ) PFM1 #VALUE!
PFM2 = PP + MSR + FS ( lb/gal ) PFM2 9.00
PFM = O maior entre PFM1 e PFM2 PFM #VALUE!

Cálculo do PFM, MSM, MSR

lb/gal
Velocidade de retirada da coluna 60 m/min MSM #VALUE!
LA ( Lâmina D'água / Air Gap ) 1413 12 m MSR 0.34
TVDT ( Topo poço aberto ) 2194.50 m
TVDB ( Base poço aberto ) 2475.00 m
PP ( Pressão de poros na TVDT ) 8.66 lb/gal
PF ( Pressão de Fratura ) 10.8 lb/gal
FS ( Fator de Segurança ) lb/gal

Over Balance Ref.: TVDT 313.4 psi

Hidrostática na TVDB 3997.1 psi

Nível Estático 218.8 @ m da mesa rotatória 193.1 bbl anular


HZupo
Alteração da Razão Sinético / Água

Volume atual de fluído 500 bbl


Fluído na retorta 74 %
Volume atual de Sintético + Água 370 bbl
Sintético Água
Razão atual de Sintético / Água 45.00% / 55.00%

Razão desejada 55.00% / 45.00%

Volume de N-parafina necessário 82.2 bbl


Volume final de fluído 582.2 bbl

Contaminação do Fluido Sintético por Água


Volume inicial de Fluido 582.2 bbl
Volume de Água incorporado ao sistema -82.2 bbl

Eng. Químico
Henrique Zupo Augusto
Retorta Fluido Base Sintético

Analise da retorta:
Sólidos não corrigidos 24.00%
Sólidos corrigidos 21.62%
Água não corrigida 38.00%
Àgua corrigida 40.38%
Sintético 38.00%

Sintético / Água
Relação Sintético / Água : 48.48% 51.52%

Analise da salinidade:
Sal: Cloreto de Sódio 1
Cl-1 Totais 40000 mg/l
Cloreto de Sódio 65941 mg/l

Salinidade na fase áquosa:


Cl-1 99055 mg/l
Cloreto de Sódio 163294 mg/l
f ( 163294 ) = 0
Eng. Químico
Henrique Zupo Augusto
TRANSFORMAÇÃO PESO BENTONITA

Sacos de Bentonita 1 1
Bentonita (ft ) 3
1 1
Sacos de Baritina 1225 59
Baritina (ft3) 1000 48

EXCESSO DE CAL HIDRATADA

Pm 1.10
Pf 0.20
Fw 0.14
Cal lb/bbl 0.28

Na2CO3 PARA PRECIPITAR Ca

Volume 1000 bbl


Dureza Total 80 ppm
Na2CO3 14.5 kg

DILUIÇÃO PARA REDUZIR SALINIDADE

Volume à ser diluído 350 bbl


% água corrigida 100.00%
Salinidade Atual 275000 mg/l
Salinidade desejada 39000 mg/l
Salinidade na água diluição 0 mg/l
Volume de diluição 2117.9 bbl

CLASSIFICAÇÃO DE LOCAÇÕES DE POÇOS

1 Pioneiro
2 Estratigráfico/Estrutural
3 Extensão
4 Pioneiro Adjacente
5 Jazida mais Rasa
6 Jazida mais Profunda
7 Desenvolvimento
8 Injeção
9 Especiais
Comprimento
In Unid Out Unid Const
1 ft 30.48 cm

Volume
In Unid Out Unid Const
1 bbl 5.614583 ft3

Massa
In Unid Out Unid Const
1 g 0.035274 oz

Vazão
In Unid Out Unid Const
1 ft3/h 0.471947 l/min

Peso específico
In Unid Out Unid Const
1 g/l 0.001 kg/l

Pressão
In Unid Out Unid Const
1 Pa 0.000145 lbf/in2

Temperatura
In Unid Out Unid Max Inc Min Difmáx Difmín Difmáx.p.Difmín
150 °F 65.56 °C HZupo
NaCl_mg/l
Input 114756 114756

%Peso NaCl_mg/l ρ_kg/l w_bbl ρ_lb/gal NaCl_lb/bbl Cl-1_mg/l Na-1_mg/l Pt Cristal_ºF At Água
10.68 114756.0 1.0758 0.9613 8.97 40.22 69718.5 45209.5 19.2 0.9296

KCl_mg/l
Input 39000.64908

%Peso KCl_mg/l ρ_kg/l w_bbl ρ_lb/gal KCl_lb/bbl Cl-1_mg/l K-1_mg/l Pt Cristal_ºF At Água
3.80 39000.6 1.0226 0.9838 8.53 13.67 18512.7 20415.7 28.9 0.9830

CaCl2_mg/l
Input 39000.64908

%Peso CaCl2_mg/l ρ_kg/l w_bbl ρ_lb/gal CaCl2_lb/bbl Cl-1_mg/l Ca-2_mg/l Pt Cristal_ºF At Água
3.78 39000.6 1.0300 0.9907 8.58 13.67 24905.9 14078.9 28.9 0.9811
Eng. Químico
Henrique Zupo Augusto
rique Zupo Augusto
Capacidades dos tanques da sonda P-16
10/5/2006
7-PM-49DB-RJS
Tanques: Capicidade bbl Volume bbl Status Fluido

At1 500
At2 500
At3 500
Res1 225
Res2 225
TratA 50
TratB 50
TratC 50
TratD 50
Sand Trap 225
Gumbo Box 24
Trip Tank 42
Slug Pill 60
Slug Mix 60
BorA 450
BorB 400
BomA 450
BomB 400
Brine 1700

BOP

Volumes

Coluna 141.2 bbl

Riser 211.8 bbl


Anular Revestimento 258.2 bbl
Poço aberto -214.5 bbl

Kill Line 6.9 bbl


Choke Line 6.9 bbl
Booster Line 0.0 bbl

Abaixo da broca -590.4 bbl

VOLUME ATUAL NO POÇO: -193.7 bbl

Volume Perdido: 1080 bbl

Eng. Químico: Henrique Zupo Augusto