Organophosphate and phthalate esters in air and settled dust–a multi‐location indoor study C Bergh, R Torgrip, G Emenius, C Östman Indoor air 21 (1), 67-76, 2011 | 435 | 2011 |
Peak alignment using reduced set mapping RJO Torgrip, M Åberg, B Karlberg, SP Jacobsson Journal of Chemometrics: A Journal of the Chemometrics Society 17 (11), 573-582, 2003 | 128 | 2003 |
A comparison of methods for alignment of NMR peaks in the context of cluster analysis J Forshed, RJO Torgrip, KM Åberg, B Karlberg, J Lindberg, SP Jacobsson Journal of Pharmaceutical and Biomedical Analysis 38 (5), 824-832, 2005 | 113 | 2005 |
Second-order peak detection for multicomponent high-resolution LC/MS data R Stolt, RJO Torgrip, J Lindberg, L Csenki, J Kolmert, I Schuppe-Koistinen, ... Analytical chemistry 78 (4), 975-983, 2006 | 107 | 2006 |
Determination of nitrate in municipal waste water by UV spectroscopy M Karlsson, B Karlberg, RJO Olsson Anal Chim Acta 312 (1), 107-113, 1995 | 102 | 1995 |
The correspondence problem for metabonomics datasets KM Åberg, E Alm, RJO Torgrip Analytical and bioanalytical chemistry 394, 151-162, 2009 | 90 | 2009 |
Feature detection and alignment of hyphenated chromatographic–mass spectrometric data: Extraction of pure ion chromatograms using Kalman tracking KM Åberg, RJO Torgrip, J Kolmert, I Schuppe-Koistinen, J Lindberg Journal of chromatography A 1192 (1), 139-146, 2008 | 87 | 2008 |
A note on normalization of biofluid 1D 1H-NMR data RJO Torgrip, KM Åberg, E Alm, I Schuppe-Koistinen, J Lindberg Metabolomics 4, 114-121, 2008 | 85 | 2008 |
Simultaneous selective detection of organophosphate and phthalate esters using gas chromatography with positive ion chemical ionization tandem mass spectrometry and its … C Bergh, R Torgrip, C Östman Rapid Communications in Mass Spectrometry 24 (19), 2859-2867, 2010 | 63 | 2010 |
Massifquant: open-source Kalman filter-based XC-MS isotope trace feature detection CJ Conley, R Smith, RJO Torgrip, RM Taylor, R Tautenhahn, JT Prince Bioinformatics 30 (18), 2636-2643, 2014 | 59 | 2014 |
Water Sorption to Hydroxyl and Carboxylic Acid Groups in Carboxymethylcellulose (CMC) Studied with NIR-spectroscopy J Berthold, RJO Olsson,L Salmén Cellulose 5 (4), 281-298, 1998 | 59 | 1998 |
Multivariate characterization of chemical and physical descriptors in pulp using NIRR RJO Olsson, P Tomani, M Karlsson, T Josefson, K Sjöberg, C Björklund Tappi Journal 78 (10), 158-166, 1995 | 56 | 1995 |
Proof of principle of a generalized fuzzy Hough transform approach to peak alignment of one-dimensional 1H NMR data L Csenki, E Alm, RJO Torgrip, KM Åberg, LI Nord, I Schuppe-Koistinen, ... Analytical and bioanalytical chemistry 389, 875-885, 2007 | 48 | 2007 |
A solution to the 1D NMR alignment problem using an extended generalized fuzzy Hough transform and mode support E Alm, RJO Torgrip, KM Åberg, I Schuppe-Koistinen, J Lindberg Analytical and bioanalytical chemistry 395, 213-223, 2009 | 34 | 2009 |
Vibrational overtone combination spectroscopy (VOCSY)—a new way of using IR and NIR data E Alm, R Bro, SB Engelsen, B Karlberg, RJO Torgrip Analytical and bioanalytical chemistry 388, 179-188, 2007 | 28 | 2007 |
New modes of data partitioning based on PARS peak alignment for improved multivariate biomarker/biopattern detection in 1H-NMR spectroscopic metabolic … RJO Torgrip, J Lindberg, M Linder, B Karlberg, SP Jacobsson, J Kolmert, ... Metabolomics 2, 1-19, 2006 | 24 | 2006 |
Increasing the scope and power of flow-injection analysis through chemometric approaches B Karlberg, R Torgrip Analytica chimica acta 500 (1-2), 299-306, 2003 | 23 | 2003 |
Extensions to peak alignment using reduced set mapping: classification of LC/UV data from peptide mapping K Magnus Åberg, RJO Torgrip, SP Jacobsson Journal of Chemometrics: A Journal of the Chemometrics Society 18 (10), 465-473, 2004 | 21 | 2004 |
Rapid X-ray based determination of moisture-, ash content and heating value of three biofuel assortments RJO Torgrip, V Fernández–Cano Biomass and bioenergy 98, 161-171, 2017 | 16 | 2017 |
Warping and alignment technologies for inter-sample feature correspondence in 1D H-NMR, chromatography-, and capillary electrophoresis-mass spectrometry data RJO Torgrip, E Alm, KM Åberg Bioanalytical Reviews 1, 105-116, 2010 | 11 | 2010 |