Mixing performance of a cross-channel split-and-recombine micro-mixer combined with mixing cell
M Juraeva, DJ Kang - Micromachines, 2020 - mdpi.com
A new cross-channel split-and-recombine (CC-SAR) micro-mixer was proposed, and its
performance was demonstrated numerically. A numerical study was carried out over a wide …
performance was demonstrated numerically. A numerical study was carried out over a wide …
A computational analysis of the train-wind to identify the best position for the air-curtain installation
M Juraeva, J Lee, DJ Song - Journal of wind engineering and industrial …, 2011 - Elsevier
This study focuses on computational analysis for the improvement of the tunnel ventilation
and the environmental control system of the subway by solving Reynold-averaged Navier–…
and the environmental control system of the subway by solving Reynold-averaged Navier–…
Mixing enhancement of a passive micromixer with submerged structures
M Juraeva, DJ Kang - Micromachines, 2022 - mdpi.com
A passive micromixer combined with two different mixing units was designed by submerging
planar structures, and its mixing performance was simulated over a wider range of the …
planar structures, and its mixing performance was simulated over a wider range of the …
Influences of the train-wind and air-curtain to reduce the particle concentration inside a subway tunnel
M Juraeva, KJ Ryu, SH Jeong, DJ Song - Tunnelling and Underground …, 2016 - Elsevier
Subways are used widely for public transportation in major cities and require efficient
ventilation systems to maintain indoor air quality in the subway tunnel. A subway tunnel was …
ventilation systems to maintain indoor air quality in the subway tunnel. A subway tunnel was …
Mixing performance of a passive micromixer based on multiple baffles and submergence scheme
M Juraeva, DJ Kang - Micromachines, 2023 - mdpi.com
A novel passive micromixer based on multiple baffles and a submergence scheme was
designed, and its mixing performance was simulated over a wide range of Reynolds numbers …
designed, and its mixing performance was simulated over a wide range of Reynolds numbers …
Mixing performance of a passive micro-mixer with mixing units stacked in cross flow direction
M Juraeva, DJ Kang - Micromachines, 2021 - mdpi.com
A new passive micro-mixer with mixing units stacked in the cross flow direction was proposed,
and its performance was evaluated numerically. The present micro-mixer consisted of …
and its performance was evaluated numerically. The present micro-mixer consisted of …
Design and Mixing Analysis of a Passive Micromixer Based on Curly Baffles
M Juraeva, DJ Kang - Micromachines, 2023 - mdpi.com
A novel passive micromixer based on curly baffles is proposed and optimized through the
signal-to-noise analysis of various design parameters. The mixing performance of the …
signal-to-noise analysis of various design parameters. The mixing performance of the …
Design and Mixing Analysis of a Passive Micromixer with Circulation Promoters
M Juraeva, DJ Kang - Micromachines, 2024 - mdpi.com
A novel passive micromixer equipped with circulation promoters is proposed, and its mixing
performance is simulated over a broad range of Reynolds numbers ( 0.1 ≤ R e ≤ 100 ). To …
performance is simulated over a broad range of Reynolds numbers ( 0.1 ≤ R e ≤ 100 ). To …
Mixing Performance of a Passive Micromixer Based on Split-to-Circulate (STC) Flow Characteristics
M Juraeva, DJ Kang - Micromachines, 2024 - mdpi.com
We propose a novel passive micromixer leveraging STC (split-to-circulate) flow
characteristics and analyze its mixing performance comprehensively. Three distinct designs …
characteristics and analyze its mixing performance comprehensively. Three distinct designs …
Influence of mechanical ventilation-shaft connecting location on subway tunnel ventilation performance
M Juraeva, KJ Ryu, SH Jeong, DJ Song - Journal of Wind Engineering and …, 2013 - Elsevier
Subways are widely used for public transportation in major cities and require efficient
ventilation systems to maintain indoor air quality in the subway tunnel. A subway tunnel was …
ventilation systems to maintain indoor air quality in the subway tunnel. A subway tunnel was …