Multi-wavelength photoplethysmography enabling continuous blood pressure measurement with compact wearable electronics

J Liu, BP Yan, YT Zhang, XR Ding… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
IEEE Transactions on Biomedical Engineering, 2018ieeexplore.ieee.org
Objective: To fight the “silent killer” hypertension, continuous blood pressure (BP) monitoring
has been one of the most desired functions in wearable electronics. However, current BP
measuring principles and protocols either involve a vessel occlusion process with a cuff or
require multiple sensing nodes on the body, which makes it difficult to implement them in
compact wearable electronics like smartwatches and wristbands with long-term wearability.
Methods: In this work, we proposed a highly compact multi-wavelength …
Objective
To fight the “silent killer” hypertension, continuous blood pressure (BP) monitoring has been one of the most desired functions in wearable electronics. However, current BP measuring principles and protocols either involve a vessel occlusion process with a cuff or require multiple sensing nodes on the body, which makes it difficult to implement them in compact wearable electronics like smartwatches and wristbands with long-term wearability.
Methods
In this work, we proposed a highly compact multi-wavelength photoplethysmography (MWPPG) module and a depth-resolved MWPPG approach for continuous monitoring of BP and systemic vascular resistance (SVR). By associating the wavelength-dependent light penetration depth in the skin with skin vasculatures, our method exploited the pulse transit time (PTT) on skin arterioles for tracking SVR (n = 20). Then, we developed an arteriolar PTT-based method for beat-to-beat BP measurement. The BP estimation accuracy of the proposed arteriolar PTT method was validated against Finometer (n = 20) and the arterial line (n = 4).
Results
The correlation between arteriolar PTT and SVR was theoretically deduced and experimentally validated on 20 human subjects performing various maneuvers. The proposed arteriolar PTT-based method outperformed the traditional arterial PTT-based method with better BP estimation accuracy and simpler measurement setup, i.e., with a single sensing node.
Conclusion
The proposed depth-resolved MWPPG method can provide accurate measurements of SVR and BP, which are traditionally difficult to measure in a noninvasive or continuous fashion.
Significance
This MWPPG work provides the wearable healthcare electronics of compact size with a low-cost and physiology-based solution for continuous measurement of BP and SVR.
ieeexplore.ieee.org